A patient has a severe vagal reaction to iodinated contrast material that includes bradycardia should be given a treatment of - *treatment includes increasing blood pressure with IV fluids *intravenous administration of atropine to block vagal stimulation of the heart All of the following are synonyms for helical scanning EXCEPT: a. volumetric scanning. b. spiral scanning. c. continuous acquisition scanning. d. dynamic scanning. - Answer— d. Dynamic scanning refers to repeating data acquisitions in the same location. Hence, it is also called nonincremental scanning. This is most frequently done to watch how a structure fills with an iodinated contrast agent. Dynamic scans are most often done using a helical scan method, but they can also be performed with axial scans. (Comprehensive Text Chapter 5 ; Heading: Helical Scanning

Content preview

CT REGISTRY- Revised Questions and Answers /
Guaranteed Pass
A patient has a severe vagal reaction to iodinated contrast material that includes bradycardia should be
given a treatment of - *treatment includes increasing blood pressure with IV fluids

*intravenous administration of atropine to block vagal stimulation of the heart



All of the following are synonyms for helical scanning EXCEPT:



a. volumetric scanning.

b. spiral scanning.

c. continuous acquisition scanning.

d. dynamic scanning. - Answer— d. Dynamic scanning refers to repeating data acquisitions in the
same location. Hence, it is also called nonincremental scanning. This is most frequently done to watch
how a structure fills with an iodinated contrast agent. Dynamic scans are most often done using a helical
scan method, but they can also be performed with axial scans. (Comprehensive Text Chapter 5 ; Heading:
Helical Scanning)



An enterovesical fistula is an abnormal communication between the bowel and the - bladder

-Typically results from inflammatory processes of the colon such as diverticulitis



An MDCT image is reconstructed using a 512x512 matrix and a display field of view of 44 cm. If the
detector collimation is set to a section width of 2.5 mm what is the volume of each voxel - How to
solve: The linear dimension of the pixel must first be calculated by dividing the DFOV, in mm, by the
matrix. This linear pixel dimension is squared to yield the pixel area in mm^2. The volume of the voxel
may be calculated by multiplying the pixel area by the section width

step 1. 44 cm/ 512 =0.0859

step 2. 0.0859*2.5 mm = 0.2148

step 3. move the decimal point =2.15 mm^3



ANATOMY COVERED CALC for MDCT: How much anatomy (lengthwise) will be covered in a helical scan
when the following parameters are selected: 15 seconds total acquisition time, .5 seconds gantry

, rotation time, 2mm slice thickness, 4 slices per rotation , pitch of 1.5? - Answer— d. To calculate
scan coverage use the formula: Pitch × total acquisition time × 1/rotation time × (slice thickness × slices
per rotation). Therefore, 1.5 × 15 × 1/0.5 s × (2 mm × 4) = 360 mm. (Comprehensive Text Chapter 5 ;
Heading: Helical Scanning/Fundamentals of Helical Technology/Helical Scan Coverage/MDCT Scan
Coverage/ Distance Covered in an MDCT Helical Scan Sequence)



ANATOMY COVERED CALC for MDCT: In an MDCT situation, programming a pitch of 1.2 and 4 slices per
rotation while acquiring images for 20 seconds using a 2.5 mm slice, and 0.5 second rotation speed will
result in how much anatomy coverage? - First use the formula : Pitch x total acquisition time x
1/rotation time x (slice thickness x slices per rotation) Therefore 1.2 x 20 x 1/0.5 x (2.5 x 4) =



Annual limits for Body, Eyes, and Skin - body: 5 rem (.05 sV, 50 mSv)

eyes: 15 rem (0.15 sV, 150 mSv)

skin: 50 rem (.5 sV, 500 mSv)



At the range of photon energies employed during most CT examinations, water exhibits an approximate
attenuation coefficient value of - 0.206



Cardiac output - the volume of blood pumped per minute by each ventricle. This is the product of
stroke volume and heart rate



normal is 4.0 - 8.0 L/min



CTDI-vol - Describes amount of E absorbed locally during the exposure

- does not reflect entire area or mass exposed or type of tissue irradiated



The dosimetry index used to approximate the radiation dose for CT sections acquired during a helical
scan



CTDIw is a weighted index that Approximate's radiation dose on the basis of variations that occur across
the field of view because of what? - Beam Hardening

Document information

Uploaded on
August 11, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lucindajohns
5.0
(2)
Sold
14
Followers
8
Items
2248
Last sold
5 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions