• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 26 pages
Exam (elaborations)

CT Registry Review Revised Questions and Answers / Guaranteed Pass

Document preview thumbnail
Preview 3 out of 26 pages

A _______ is a benign, highly vascular mass commonly found in the liver. - hemangioma A ________ infection is one that a patient acquires during a stay in a health care institution. - Nosocomial A 16-slice MSCT system utilizes an adaptive array of 24 detectors, each ranging in size from 0.625 to 1.25 mm. What is the maximum number of sections the system can acquire with each rotation of the gantry? - 16 A common site for the IV administration of iodinated contrast media is the anterior recess of the elbow, otherwise known as: - antecubital space. A complete CT study of the orbits should include: - 2.5 mm x 2.5 mm axial and coronal sections A CT angiogram (CTA) of the neck is performed primarily for the evaluation of the: - carotid arteries. A CT image is displayed in a window with a level of +200 and a width of 1000. What are the pixel values? - Between -300 HU and +700 HU will be assigned shades of gray A CT image is displayed in a window with a level of 0 and a width of 500. Which of the following statements are correct? - Pixels with values between -250 HU and +250 HU will be assigned shades of gray.

Content preview

CT Registry Review Revised Questions and
Answers / Guaranteed Pass
A _______ is a benign, highly vascular mass commonly found in the liver. - hemangioma



A ________ infection is one that a patient acquires during a stay in a health care institution. -
Nosocomial



A 16-slice MSCT system utilizes an adaptive array of 24 detectors, each ranging in size from 0.625 to 1.25
mm. What is the maximum number of sections the system can acquire with each rotation of the gantry?
- 16



A common site for the IV administration of iodinated contrast media is the anterior recess of the elbow,
otherwise known as: - antecubital space.



A complete CT study of the orbits should include: - 2.5 mm x 2.5 mm axial and coronal sections



A CT angiogram (CTA) of the neck is performed primarily for the evaluation of the: - carotid
arteries.



A CT image is displayed in a window with a level of +200 and a width of 1000. What are the pixel values?
- Between -300 HU and +700 HU will be assigned shades of gray



A CT image is displayed in a window with a level of 0 and a width of 500. Which of the following
statements are correct? - Pixels with values between -250 HU and +250 HU will be assigned
shades of gray.



A CT image is formed in part by projecting back all of the attenuation values recorded during data
acquisition onto a: - matrix.

,A CT image is formed in part by projecting back all of the attenuation values recorded during data
acquisition onto a: - matrix.



A CT system measures the average linear attenuation coefficient of a voxel of tissue to be 0.008. The
linear attenuation coefficient of water for this scanner equals 0.181. The CT number assigned to the pixel
representing this voxel of tissue equals: - -956 HU



A first generation CT scanner consists of an x-ray tube and two detectors that translate across the
patient's head while rotating in 1 degree increments for a total of: - 180 degrees.



A focused, thin-section axial CT acquisition through just the region of the vocal cords should extend: -
From just above the hyoid bone inferiorly through the cricoid cartilage.



A normal range for diastolic blood pressure in an adult is? - 60-90 mm Hg



A patient in shock may exhibit which of the following symptoms? - Tachycardia, cyanosis, rapid,
and shallow breaths.



A patient's blood pressure is measured as 140/70 mm Hg. The number 140 represents? - The
pressure within the arterial vessel during contraction of the heart.



A primary responsibility of computed tomography in combined PET-CT is to: - Provide precise
anatomic location of tumor activity.



A region of interest (ROI) measurement placed over a portion of a CT image provides what type of
number? - Average CT Number (HU-Hounsfield Units)



A scintillation detector has a higher capture efficiency than? - A gas ionization chamber



A standard CT image reconstructed on a 512^2 matrix has a digital size of approximately... - 0.5
MB.

, A total volume of 125 mls of an iodinated contrast agent is administered intravenously via automatic
injector in 50 seconds. The flow rate for this injection is? - 2.5 mL/sec



A(n) _________ contrast material may be described as one that does not dissociate into charged
particles in solution. - non-ionic



Abnormalities of the middle and inner ear may be best demonstrated with CT utilizing _________
sections. - 1-2 mm



Accurate demonstration of ____________ would most likely require the intravenous injection of an
iodinated contrast agent during a CT study of the chest. - mediastinal lymphadenopathy



Advantages of a saline flush immediately following the IV administration of iodinated contrast media
include: - Reduction in required contrast agent dose, reduction in the incidence of contrast-
induced nephrotoxicity (CIN) and reduction of streaking artifacts from dense contrast agents in the
vasculature.



After initiation of rapid bolus administration of an iodinated contrast agent, he portal venous phase of
hepatic contrast enhancement occurs at approximately: - 60-70 seconds.



After initiation of rapid bolus administration of an iodinated contrast agent, the arterial phase of hepatic
contrast enhancement occurs at approximately? - 25-35 seconds



After initiation of rapid bolus administration of iodinated contrast material, the pancreatic phase of
contrast enhancement occurs at approximately: - 35-45 seconds.



Air trapping within the trachea and bronchial tree may be optimally demonstrated with multiplanar
volume reconstructions (MPVR) of the thorax known as: - minimum intensity projections (min-
IPs).



An acquisition is made on a 64-slice MSCT system in which each detector element has a z-axis dimension
of 0.625 mm. With a selected beam width of 40 mm and the beam pitch set at 1.50, how much will the
table move with each rotation of the gantry? - 60 mm

Document information

Uploaded on
August 11, 2024
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lucindajohns
5.0
(2)
Sold
14
Followers
8
Items
2248
Last sold
5 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions