S95 Personal Exam With Correct Questions
And Answers 2024
Which bduties bcan ban bS-95 bCertificate bof bFitness bholder bperform? b- bcorrect
banswer.Visual bInspections bOnly b- bof bfire balarm bsystem bcomponents band bsmoke
bdetectors
What bis bthe bprimary bpurpose bof bFire bAlarm bSystems? b- bcorrect banswer.To bwarn
bbuilding boccupants band btransmit bsignals bindicating ba bfire bcondition bto bthe bFire
bDepartment bvia bcentral bstation.
What bis ba bFire bAlarm bsignal? b- bcorrect banswer.The bsignal binitiated bby ba bfire balarm
binitiating bdevice bsuch bas ba bmanual bfire balarm bpull bstation, bsmoke bdetector, bwater-flow
bswitch, bor bany bdevice bin bwhich btheir bactivation bindicates bpresence bof bfire.
What bis ba bSupervisory bSignal? b- bcorrect banswer.A bsignal bindicating bthat ba bsystem bor
bdevice bbeing bmonitored bhas bbeen bcompromised bor bis bin ban babnormal bstate.
Is bthe bFDNY bdispatched bfor bSupervisory bSignals? b- bcorrect banswer.No. bThe bFacility
bManager bshould binvestigate band bcorrect bthe bsupervisory bcondition bindicated bby bthe
bFACP.
What bis ba bTrouble bSignal? b- bcorrect banswer.A bsignal bthat bindicates ba bfault bwith bthe bfire
bequipment. bIt bmust bhave ban baudible bsignal, bdistinctive bfrom balarm bsignals
What bis bthe bmaximum bnumber bof bminutes bthat broutine bhandling bshould btake?-- bfrom
breceipt bof btrouble bsignal bby bcentral bstation buntil binitiation bof bthe binvestigation bby
btelephone. b- bcorrect banswer.FOUR bminutes
Is bthe bFDNY bdispatched bfor bTrouble bSignals? b- bcorrect banswer.No. bTrouble bSignals
baren't bindicative bof ba bfire bcondition.
What bis ban bAcknowledge bSwitch b(ACK) b? b- bcorrect banswer.This bswitch/button bis bused
bto backnowledge balarm, bsupervisory, bor btrouble bconditions.
Why bis ban bAlarm bSilence bSwitch bhelpful bafter ban bevacuation b- bwhile bthe bsource bof
balarm bis bbeing binvestigated? b- bcorrect banswer.This bswitch/button bsilences baudible band
bvisual bdevices b(sirens, bbells, bgongs) bso bit's beasier bfor bEmergency bResponders bto
bcommunicate.
, Which bswitch/button bis bpushed bonce ban balarm bcondition bis bcleared? b- bcorrect
banswer.The bSystem bReset bSwitch
Smoke bDetectors bshould bbe bcleaned bnot bless bthan b- bcorrect banswer.Once bevery bsix
bmonths
How boften bshould bAnalog bSmoke bDetectors bbe bcleaned? b- bcorrect banswer.One bweek
bfrom breceipt bof ban bindication bthat bcleaning bis bneeded.
How boften bshould bSmoke bDetectors bbe btested bfor bsmoke bentry? b- bcorrect banswer.Not
bless bthan bonce ba byear
After bactivation, bwhich btype bof bheat bdetector bself-restores? bWhich btype bdoesn't? b-
bcorrect banswer.Fixed-Temperature bheat bdetectors: bDoesn't bself b-restore band brequires
breplacement. bRate bof bRise bheat bdetectors: bself-restore
Fire bAlarm bCircuits' bprimary bpower bsource bshouldn't bgenerate belectric bpower bexceeding
bwhich bvoltage? b- bcorrect banswer.277/480 bvolts
All babnormal bconditions bbe binvestigated band bnoted bwhere? b- bcorrect banswer.A bbound
bLog bBook
Alarm bNotification bAppliance b- bcorrect banswer.A bfire balarm bsystem bcomponent b(bell,
blight, betc.) bthat bissues ban baudible, btactile, bor bvisual balert.
Annunciator b- bcorrect banswer.A bunit bcontaining bone bor bmore bindicator blamps,
balphanumeric bdisplays, betc. bin bwhich beach bindication bprovides bstatus binfo babout ba
bcircuit, bcondition, bor blocation.
ARCS b(Auxiliary bRadio bCommunication bSystem) b- bcorrect banswer.A bwireless btwo-way
bbuilding bcommunication bsystem bfor bFire bDept. buse bonly.
Accessibility b- bcorrect banswer.Admitting bclose bapproach- bnot bguarded bby blocked bdoors,
belevation, betc.
Initiating bDevice b- bcorrect banswer.A bsystem bcomponent bthat boriginates btransmission bof
ba bchange-of-state bcondition, bsuch bas bin ba bsmoke bdetector, bmanual bfire balarm bbox, bor
bsupervisory bswitch.
Nuisance bAlarm b- bcorrect banswer.An balarm bcaused bby bmechanical bfailure, bmalfunction,
bimproper binstallation, bimproper bmaintenance bor ban bundetermined bcause.
Plenum b- bcorrect banswer.The bopen bspace bthat bcarries bair bbetween bthe bceilings band
bfloor babove.
And Answers 2024
Which bduties bcan ban bS-95 bCertificate bof bFitness bholder bperform? b- bcorrect
banswer.Visual bInspections bOnly b- bof bfire balarm bsystem bcomponents band bsmoke
bdetectors
What bis bthe bprimary bpurpose bof bFire bAlarm bSystems? b- bcorrect banswer.To bwarn
bbuilding boccupants band btransmit bsignals bindicating ba bfire bcondition bto bthe bFire
bDepartment bvia bcentral bstation.
What bis ba bFire bAlarm bsignal? b- bcorrect banswer.The bsignal binitiated bby ba bfire balarm
binitiating bdevice bsuch bas ba bmanual bfire balarm bpull bstation, bsmoke bdetector, bwater-flow
bswitch, bor bany bdevice bin bwhich btheir bactivation bindicates bpresence bof bfire.
What bis ba bSupervisory bSignal? b- bcorrect banswer.A bsignal bindicating bthat ba bsystem bor
bdevice bbeing bmonitored bhas bbeen bcompromised bor bis bin ban babnormal bstate.
Is bthe bFDNY bdispatched bfor bSupervisory bSignals? b- bcorrect banswer.No. bThe bFacility
bManager bshould binvestigate band bcorrect bthe bsupervisory bcondition bindicated bby bthe
bFACP.
What bis ba bTrouble bSignal? b- bcorrect banswer.A bsignal bthat bindicates ba bfault bwith bthe bfire
bequipment. bIt bmust bhave ban baudible bsignal, bdistinctive bfrom balarm bsignals
What bis bthe bmaximum bnumber bof bminutes bthat broutine bhandling bshould btake?-- bfrom
breceipt bof btrouble bsignal bby bcentral bstation buntil binitiation bof bthe binvestigation bby
btelephone. b- bcorrect banswer.FOUR bminutes
Is bthe bFDNY bdispatched bfor bTrouble bSignals? b- bcorrect banswer.No. bTrouble bSignals
baren't bindicative bof ba bfire bcondition.
What bis ban bAcknowledge bSwitch b(ACK) b? b- bcorrect banswer.This bswitch/button bis bused
bto backnowledge balarm, bsupervisory, bor btrouble bconditions.
Why bis ban bAlarm bSilence bSwitch bhelpful bafter ban bevacuation b- bwhile bthe bsource bof
balarm bis bbeing binvestigated? b- bcorrect banswer.This bswitch/button bsilences baudible band
bvisual bdevices b(sirens, bbells, bgongs) bso bit's beasier bfor bEmergency bResponders bto
bcommunicate.
, Which bswitch/button bis bpushed bonce ban balarm bcondition bis bcleared? b- bcorrect
banswer.The bSystem bReset bSwitch
Smoke bDetectors bshould bbe bcleaned bnot bless bthan b- bcorrect banswer.Once bevery bsix
bmonths
How boften bshould bAnalog bSmoke bDetectors bbe bcleaned? b- bcorrect banswer.One bweek
bfrom breceipt bof ban bindication bthat bcleaning bis bneeded.
How boften bshould bSmoke bDetectors bbe btested bfor bsmoke bentry? b- bcorrect banswer.Not
bless bthan bonce ba byear
After bactivation, bwhich btype bof bheat bdetector bself-restores? bWhich btype bdoesn't? b-
bcorrect banswer.Fixed-Temperature bheat bdetectors: bDoesn't bself b-restore band brequires
breplacement. bRate bof bRise bheat bdetectors: bself-restore
Fire bAlarm bCircuits' bprimary bpower bsource bshouldn't bgenerate belectric bpower bexceeding
bwhich bvoltage? b- bcorrect banswer.277/480 bvolts
All babnormal bconditions bbe binvestigated band bnoted bwhere? b- bcorrect banswer.A bbound
bLog bBook
Alarm bNotification bAppliance b- bcorrect banswer.A bfire balarm bsystem bcomponent b(bell,
blight, betc.) bthat bissues ban baudible, btactile, bor bvisual balert.
Annunciator b- bcorrect banswer.A bunit bcontaining bone bor bmore bindicator blamps,
balphanumeric bdisplays, betc. bin bwhich beach bindication bprovides bstatus binfo babout ba
bcircuit, bcondition, bor blocation.
ARCS b(Auxiliary bRadio bCommunication bSystem) b- bcorrect banswer.A bwireless btwo-way
bbuilding bcommunication bsystem bfor bFire bDept. buse bonly.
Accessibility b- bcorrect banswer.Admitting bclose bapproach- bnot bguarded bby blocked bdoors,
belevation, betc.
Initiating bDevice b- bcorrect banswer.A bsystem bcomponent bthat boriginates btransmission bof
ba bchange-of-state bcondition, bsuch bas bin ba bsmoke bdetector, bmanual bfire balarm bbox, bor
bsupervisory bswitch.
Nuisance bAlarm b- bcorrect banswer.An balarm bcaused bby bmechanical bfailure, bmalfunction,
bimproper binstallation, bimproper bmaintenance bor ban bundetermined bcause.
Plenum b- bcorrect banswer.The bopen bspace bthat bcarries bair bbetween bthe bceilings band
bfloor babove.