CA State Elevator Mechanic Study Guide Questions and Answers
Ladder must be installed if pit is deeper than... Ans- 35" (3') ASME A 17.1 - 2004 2.2.4.2 Ladder shall not extend more than ___ above the sill. Ans- 48" (4') ASME A 17.1 - 2004 2.2.4.2 Rungs (cleats or steps) of ladder should be a minimum of ___ wide. Ans- 16" ASME A 17.1 - 2004 2.2.4.2 Siderails shall have a clear distance of not less than ___ from their centerline to the nearest permanent object. Ans- 4.5" ASME A 17.1 - 2004 2.2.4.2 Ladder access shall not be permitted if pit is deeper than ___ below the sill of the access door. Ans- 120" (10') ASME A 17.1 - 2004 2.2.4.2 Illumination of pit and platform should be___. Ans- 10FC ASME A 17.1 - 2004 2.2.5.1 Where should the light switch be located in the pit? Ans- Where accessible from the pit access door. ASME A 17.1 - 2004 2.2.6.1