International Mechanical Code The code official - Answer- When requirements necessary for proper operation of a proposed mechanical system are not specifically covered by the code, such requirements shall be determined by____________________. State the reason for disapproval in writing to the applicant - Answer- Where the code official finds that a proposed alternative material does not comply with the intent of the code provisions, the code official shall _________________. Interpret - Answer- The code official has the authority to______________the provisions of the code. At the job site - Answer- One set of construction documents shall be kept_______________until completion of the project. Holder of the permit - Answer- The______________shall be responsible for the scheduling of inspections. Ground source heat pump loop systems - Answer- Which of the following installations is permitted to be backfilled prior to an underground inspection? Code official - Answer- Mechanical systems shall be tested, with such test made by the permit holder and observed by the________________. 10 - Answer- A permit is not required for a self-contained refrigeration system that contains a maximum of_______________pound(s) of refrigerant. International energy conservation code - Answer- Heating, Ventilating and air-conditioning systems shall be designed and installed for efficient use of energy in accordance with the________________. Manufacturer's - Answer- Appliances that are part of the building mechanical system shall not be converted to a different fuel, except where approved and in accordance with the_______________instructions. 2 - Answer- Bored holes for the installation of piping shall be located at least______________Inch(es) From the top and bottom of the solid wood joist. 33 1/3 - Answer- A bored hole in the floor joist is limited in diameter to__________Percent of the depth of the joist. 1/6 - Answer- Notches in the top or bottom of solid wood joists are limited to_______________of the depth of the joists. 1/3 - Answer- Notches in the top or bottom of solid wood joists shall not be located in the middle______________of the span. 40 - Answer- Studs used in non-bearing partitions are permitted to be cut or notched to a maximum depth of______________percent of the stud depth. 60 - Answer- For studs in a non-bearing partition, the maximum permitted diameter of a bored hole is______________Percent of the depth of the stud. 5/8 - Answer- Bored holes shall not be near than______________inch to the edge of the stud. Be listed for installation in the closet - Answer- A boiler installed in the closet must__________________. 18 - Answer- When located within a repair garage, appliances with an ignition source shall be elevated such that the ignition source is a minimum of________________inches above the garage floor. Oil fired boiler in the storage closet - Answer- The installation of a(n) ______________is prohibited.

Content preview

International Mechanical Code
The code official - Answer- When requirements necessary for proper operation of a proposed mechanical system are not specifically covered by the code, such requirements shall be determined by____________________.
State the reason for disapproval in writing to the applicant - Answer- Where the code
official finds that a proposed alternative material does not comply with the intent of the code provisions, the code official shall _________________.
Interpret - Answer- The code official has the authority to______________the provisions of the code.
At the job site - Answer- One set of construction documents shall be kept_______________until completion of the project.
Holder of the permit - Answer- The______________shall be responsible for the scheduling of inspections.
Ground source heat pump loop systems - Answer- Which of the following installations is permitted to be backfilled prior to an underground inspection?
Code official - Answer- Mechanical systems shall be tested, with such test made by the permit holder and observed by the________________.
10 - Answer- A permit is not required for a self-contained refrigeration system that contains a maximum of_______________pound(s) of refrigerant.
International energy conservation code - Answer- Heating, Ventilating and air-
conditioning systems shall be designed and installed for efficient use of energy in accordance with the________________.
Manufacturer's - Answer- Appliances that are part of the building mechanical system shall not be converted to a different fuel, except where approved and in accordance with the_______________instructions.
2 - Answer- Bored holes for the installation of piping shall be located at least______________Inch(es) From the top and bottom of the solid wood joist.
33 1/3 - Answer- A bored hole in the floor joist is limited in diameter to__________Percent of the depth of the joist.
1/6 - Answer- Notches in the top or bottom of solid wood joists are limited to_______________of the depth of the joists.
1/3 - Answer- Notches in the top or bottom of solid wood joists shall not be located in
the middle______________of the span.
40 - Answer- Studs used in non-bearing partitions are permitted to be cut or notched to a maximum depth of______________percent of the stud depth.
60 - Answer- For studs in a non-bearing partition, the maximum permitted diameter of a bored hole is______________Percent of the depth of the stud.
5/8 - Answer- Bored holes shall not be near than______________inch to the edge of
the stud.
Be listed for installation in the closet - Answer- A boiler installed in the closet must__________________.
18 - Answer- When located within a repair garage, appliances with an ignition source
shall be elevated such that the ignition source is a minimum of________________inches above the garage floor.
Oil fired boiler in the storage closet - Answer- The installation of a(n) ______________is prohibited.

Document information

Uploaded on
August 1, 2024
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Freshy
3.6
(11)
Sold
64
Followers
4
Items
6965
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions