• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 45 pages
Exam (elaborations)

Surgical Technology Certification Exam Questions With Verified Answers.

Document preview thumbnail
Preview 4 out of 45 pages

Surgical Technology Certification Exam Questions With Verified Answers. The surgeon asks that multiple suture and hernia mesh that were not on the preference card be opened during the repair of a large umbilical hernia. The surgical technologist should recognize that: a. items on the preference card are only to be changed by the surgeon or the unit clerk b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh to the preference card c. preference card changes are unnecessary; both hernia mesh and suture are case dependent. d. suture may be case dependent, but the hernia mesh is integral to the procedure and should be added to the preference card - answerAnswer: D Which of the following precautions should be taken by the surgical team when working with polymethyl methacrylate as a bone cement? a. wear latex free gloves, as polymethyl methacrylate interacts negatively with latex b. remove contact lenses as polymethyl methacrylate can melt contact lenses and cause corneal burns c. make sure the patient does not have a latex allergy because polymethyl methacrylate and latex have the same chemical properties d. Limit the # of sponges on the field as polymethyl methacrylate can negatively interact with the cotton fibers in the sponges. - answerAnswer: B Which of the following daily tests must be performed on the pre-vacuum sterilizer before using it? a. Gravity b. Biological indicator c. Bowie-Dick d. Chemical indicator - answerAnswer: C What is the minimum exposure time in a flash sterilizer for unwrapped instruments? a. 1 minute b. 3 minutes c. 5 minutes d. 7 minutes - answerAnswer: B [pre-vac] no lumen - 3 minutes ; lumen - 4 minutes Which of the following is the correct temperature for the flash sterilizer operation? a. 132*C (270*F) b. 126*C (260*F) c. 135*C (275*F) d. 129*C (265*F) - answerAnswer: A Which of the following is the proper temperature and time that the chamber of a steam sterilizer must reach in order to ensure that all spores have been eliminated? a. 270*F for 4 minutes b. 350*F for 4 minutes c. 240*F for 10 minutes d. 350*F for 10 mintues - answerAnswer: A [pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi The Sterrad sterilization system most commonly uses which of the following chemical solutions? a. hydrogen peroxide b. gluteraldehyde c. alcohol d. peracetic acid - answerAnswer: A [Sterrad] make sure its plugged in - needs electricity Which of the following is used to achieve high level disinfection with a minimum exposure time of 20-45 minutes? a. chlorine bleach compounds b. gluteraldehyde c. hydrogen peroxide d. iodine and iodophors - answerAnswer: B During decontamination of a flexible endoscope, which of the following tests should be given to inspect the proper function of the endoscope and to ensure that it can be properly sterilized? a. leak test b. electrical component test c. bacteria swab test d. fiber optic light test - answerAnswer: A Which of the following is the fastest method of sterilization? a. gas b. steam c. steris d. dry heat - answerAnswer: B Which of the following is the correct temperature for pre-vacuum sterilization? a. 212*F b. 170*F c. 300*F d. 270*F - answerAnswer: D Which of the following tests is specifically meant to test and monitor the efficiency of the high - vacuum steam sterilizer? a. biological indicator test b. DART test c. chemical indicator test d. EtO test - answerAnswer: B DART test = Bowie Dick test The surgical team must verify each package is properly labeled with a. date of processing and method of sterilization b. date of processing and indicator c. method of sterilization and expiration date d. indicator and expiration date - answerAnswer: B How many times a day should a DART test be preformed? a. with every load b. every shift change c. once every 24 hours d. weekly - answerAnswer: C How often must a biological control test be run? a. every day b. every cycle c. once a week d. once a month - answerAnswer: A [pg. 163] The Bowie-Dick test for pre-vacuum sterilizers checks for which of the following conditions? a. that the appropriate steam level was reached b. air leaks in the sterilizer chamber c. broken sterilizer jacket d. that the sterilizer is ready to process instruments - answerAnswer: B lot control numbers should be placed on each package sterilized and on the... a. sterilizer maintenance record b. sterilization load record c. nursing documentation d. cover of the patient's chart - answerAnswer: B How long is a 3M Attest 1292 steam biological indicator incubated before the reading is recorded? a. 12 hours b. 36 hours c. 24 hours d. 48 hours - answerAnswer: C 12 hours - rapid ; 24 hours - not rapid


Document information

Uploaded on
July 3, 2024
Number of pages
45
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay
3.7
(78)
Sold
436
Followers
82
Items
21573
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.