FDNY Fire Life & Safety Director Test 2 with Complete Solutions
FDNY Fire Life & Safety Director Test 2 with Complete Solutions A Fire Life Safety Director should be familiar with which of the following EXCEPT? How to manually programmed the HVAC system via the BMS (Building Management System). When a Fire Life Safety Director is conducting fire drills for the occupants, they should be instructed to always notify ______ first in the event of a fire condition. 911 The fire triangle identifies the three needed components of fires as which of the following: - Oxygen - Fuel - Heat A Deputy Fire Warden shall be provided for each tenancy. When the floor area of a tenancy exceeds a certain amount of square feet of occupied space, a Deputy Fire Warden shall be assigned for each: 7,500 square feet or part thereof Which of the following are associated with the means of egress? - Exit access - Exit - Exit discharge Fire drills in a new office building must be conducted at least _________ in the first 2 years following acceptance of a Comprehensive Fire Safety and Emergency Action Plan. Quarterly During a fire drill, occupants should be instructed to FIRST notify _____ in the event of a fire 911 The qualified building service employees who consists of the Fire FLS Brigade are organized, selected and trained by: The Fire Life Safety Director Which type of detector will activate the alarm when the room temperature increases at a rapid rate (12-15 degrees F per minute)? The alarm will reset itself, when the room temperature returns back to normal. Rate-of-rise heat detector The primary purpose of the ___________ is to process signals received from initiating devices and to activate appropriate signals and outputs. Fire alarm control panel A supply of at least six spare sprinkler heads must be kept available on the premises near what location? Main control valve ________ emergency in-car operation allows fire fighters to control the elevator, and travel to any floor served by the elevator. The operating controls are located inside the elevator car. Only trained personnel or first responders should use this feature. Phase II What type of fire protection device will automatically recall elevators to the designated landing? Elevator lobby smoke detectors If you are looking at a stairway door and notice a number on the door, which of the following is TRUE? You're on the stair side of a door. After the test of smoke control system has been completed, the FLS Director must ensure all the required entries are made in the FLS Logbook. The required entries include all the following information, EXCEPT: (Refer to the Reference material) The manufacturer's company address The transfer of heat through solid surfaces such as metal pipes or duct-work is called: Conduction During a fire drill, the occupants should be advised that if fire alarm systems activate with no additional information, they should move ___________. At least 3 floors below their present location Which of the following conditions WILL NOT result in an automatic release of the fail-safe locks in a high rise building?
Written for
- Institution
- FDNY Fire Life & Safety
- Course
- FDNY Fire Life & Safety
Document information
- Uploaded on
- May 28, 2024
- Number of pages
- 20
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
fdny fire life safety director test 2 with comp
Also available in package deal