EPA 608 TYPE 3 2024 |139 QUESTIONS WITH CORRECT ANSWERS ALREADY PASSED AND VERIFIED

Document preview thumbnail
Preview 2 out of 14 pages

On low pressure chillers, moisture typically enters the refrigerant system through - CORRECT ANSWER air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - CORRECT ANSWER 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - CORRECT ANSWER ... A hydrostatic tube test kit is used to: - CORRECT ANSWER determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. - CORRECT ANSWER 35% Refrigerant recovery typically start with liquid recovery it is faster. - CORRECT ANSWER ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - CORRECT ANSWER 15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. - CORRECT ANSWER 2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. - CORRECT ANSWER local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? - CORRECT ANSWER 16.9" Hg vacuum After recovering the liquid refrigerant you must: - CORRECT ANSWER recover the vapor refrigerant According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - CORRECT ANSWER 100 pounds Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: - CORRECT ANSWER system water to freeze A system does not have to be evacuated all the way to the required level when: - CORRECT ANSWER leaks in the appliance make evacuation to the prescribed level unattainable Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - CORRECT ANSWER replacement of evaporator coil Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non major repair? - CORRECT ANSWER warming the refrigerant If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. - CORRECT ANSWER 25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should - CORRECT ANSWER Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil The pressure corresponding to 32 F for R-123 - CORRECT ANSWER 20 inches of HG vacuum When evacuating a system the use of too large a vacuum pump can cause? - CORRECT ANSWER trapped water to freeze Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - CORRECT ANSWER 35F


Document information

Uploaded on
May 5, 2024
Number of pages
14
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACELEARNERS
4.2
(75)
Sold
313
Followers
181
Items
3631
Last sold
4 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.