Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 19 pages
Exam (elaborations)

Texas Ext Type B TFM02 Exam Questions With Verified Answers, Latest Update 2024/2025 (Graded A+)

Document preview thumbnail
Preview 3 out of 19 pages

A three-dimensional fire often involves static flammable liquid. true or false - correct answers false. 3D fires involve flammable liquid in motion as well as both horizontal and vertical surfaces. Class A fire extinguisher - correct answers are ok for wood, paper, some plastics and textiles. They offer the coating effects of dry chemicals. Dry chemical stored pressure fire extinguishers: - correct answers should be removed or replaced at their next 6-year maintenance or hydrostatic test interval. B:C - correct answers Talking about UL rating, the _____ rating refers to the amount of sq footage an extinguisher covers Class B fire extinguishers cannot handle flammable liquid - correct answers False employees must be trained in proper use of all portable fire extinguishers according to - correct answers CRF29 Texas Ext Type B TFM02 Exam Questions With Verified Answers Latest Update 2024/2025 Graded A+ monthly - correct answers you need to have portable fire extinguishers VISUALLY inspected at least _____ according to 29 CFR 1910.157 (e) (2) Class A/B fire extinguishers - correct answers should NOT be used forfire that involves live electrical equipment annually - correct answers Water or steam fire extinguishers need to be discharged, dissassembled and inspected at least: 3.5 ft - correct answers An extinguisher weighing over 40 lbs should be installed so the top is no more than __ from the ground 50 ft. - correct answers OSHA specified maximum travel distance to an extinguisher for Class B 6 yrs - correct answers dry chem extinguishers requiring 12 yr hydrostatic test must be emptied for maintenance procedures every A rated UL extinguishers = how many gallons of water? - correct answers 1.25 C - correct answers Class ____ fire extinguishers use electrically nonconductive extinguishing agents Every 5 years - correct answers Cartridge operated water based portable extinguishers need hydrostatic testing stored pressure type extinguishers need need INTERNAL examination : - correct answers never 5 ft above the ground - correct answers extinguishers weighing 40 lbs or less must be installed so top of canister is no more than _____ K - correct answers class ___ extinguishers are for fires involving cooking media 75 ft - correct answers OSHA specified max travel distance for Class A is ______ C - correct answers proper UL rating to use on electrically energized equipped Class K - correct answers work on the principle of saponification Obstacle Type Fires - correct answers involve flammable liquid on a horizontal surface w/ the presence of a solid object creating a barrier 4 inches - correct answers extinguishers must be installed at least _____ from the ground Obstacle Type Fires - correct answers may take place in flammable liquid storage caninets, dip tank process areas, etc. Must Be Weighed - correct answers To make sure the pressure gauges of CO2 extinguisher are showing adequate pressure, what must you do? 5 yrs - correct answers Wetting agent portable extinguishers must be hydrostatic tested every _____ After recharge - correct answers leak tests on stored pressure extinguishers must be performed cannot - correct answers how do u convert fire extinguishers from 1 type to another? any remaining dry chemical in a discharged extinguisher - correct answers may be reused only if checked for proper type, contamination, and condition. closed recovery system needs to be used! New extinguishers needing charge in the field - correct answers do not need to have any verification of service collar installed you cannot - correct answers how do u have an extinguisher converted to use a different type of extinguishing agent annually - correct answers the gauge used to set the regulated source of pressure needs to be calibrated annually - correct answers pump tank calcium chloride based antifreeze typesof extinguishers need to be recharged 75 ft. - correct answers OSHA specified max distance to extinguisher for Class D weighing - correct answers when you recharge, the amount of recharge agent to use should be verified by Aqueous Film Forming Foam (AFFF) - correct answers these types of extinguishers must have hydrostatic testing every 5 yrs annually - correct answers The wetting agent in stored pressure wetting agent extinguishers must be replaced 3 yrs - correct answers The premixed agent in liquid charge-type AFFF and FFFP extinguishers must be replaced every cylinder-operated extinguishers - correct answers do not need to have any verification of service collar installed False - correct answers you are free to mixmultipurpose dry chemicals w/ alkaline based dry chemicals must be avoided - correct answers subsurface injection of wet chemical extinguishing agents into hot cooking media False - correct answers You should NEVER place extinguishers in cabinets or wall recesses. 5 yrs - correct answers how often must CO2 portable extinguishers go through hydrostatic testing?


Document information

Uploaded on
April 20, 2024
Number of pages
19
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUDYROOM2026
3.5
(64)
Sold
412
Followers
212
Items
3879
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.