BICSI Practice Test 2024 All Possible Questions and Answers with complete
The 2 main considerations concerning the existing cabling are? - Answer-Grandfathered system Abandoned cable 11-25 The type of cutover where cross-connects are relocated one pair after another until completed is called a - Answer-rolling cut 11-28 Which practice involves moving the customer to a temporary office space until their section of the retrofit is completed and then moving them back to their recabled office space? - Answer-Swing space phasing Which of these testers would you clamp around a strand of fiber to check for the presence of light? - Answer-Fiber strand identifier 11-11 A ______ provides a quick graphical representation of how the circuit is layed out? - Answer-CLR 11-27 A ______ uses several pluggable modules to locate and Identify cables. - Answer-Office locator kit A _________ injects light (at a proper wavelength) and measures the results t the other end. - AnswerLight source and power meter A ________ detects the presence of light within a fiber strand - Answer-Fiber strand identifier A _______ uses a laser to identify fiber strands and find breaks in the fiber at the near end. - AnswerVisual fault locator A________ will leave the customer momentarily without communications - Answer-Hot-cut 11-28 During a _______, cross-connects are relocated one pair after another until completed. - Answer-Rolling cut*_________ is a property of an electromagnetic field built around a conductor that opposes any changes in current flow in a circuit. - Answer-Inductance ____________ is a property of conductors that allows storage of electrical charges when potential differences (voltages) exist between the conductors. - Answer-Capacitance *In AC circuits, the total opposition to current flow is called _________, which is measured in ohms. - Answer-Impedance The nominal characteristic impedance of balanced twisted pair cable is _______ ohms at 100 MHz - Answer-100 Pair 626 would be in the __________ Super Binder - Answer-Red Series ______ is the preferred choice for longer runs - Answer-11 The _________ connector/s have center pins (choose all that apply) - Answer-N BNC The way in which others perceive an employee can be divided into 3 distinct areas: body language, Tone of voice and choice of words. Which of the 3 makes the biggest impression? - Answer-Body language - 55% The range of human hearing is from _________ - Answer-20 Hz- 20,000 Hz An increase of _______ will result in a doubling or halving of the power. - Answer-3 dB Increases or decreases of ________ for voltage will cause an increase or decrease of 10 times the original value. - Answer-6 dBThe code stands for "flush-or surface-mounted jack" - Answer-C A "push to talk" intercom system would be an example of a ______ transmission method. - Answer-halfduplex 1-1 __________ quantifies the bandwidth of a cabling system in a frequency range of interest. - AnswerMegahertz _________ refers to the amount of information that can be transported over the media. - AnswerMegabit A gauge change of ____ numbers approximately doubles or halves the conductors resistance - Answer-3 A gauge change of _______numbers approximately doubles or halves the conductors diameter - Answer- 6 ______ is not recommended for new installations (what type of fiber) - Answer-OM2
Written for
- Institution
- BICSI
- Course
- BICSI
Document information
- Uploaded on
- April 18, 2024
- Number of pages
- 11
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
Also available in package deal