BICSI Technician HW #2 Questions With Correct Answers 100%
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - Answer-Backbone cable The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? - Answer-Connection hardware What is the maximum length of a patch cord? - Answer-16.4' You are installing horizontal structured cabling in an open office environment with modular furniture. You are using category 6A cabling. You have to terminate 22 cabling runs in each modular furniture cluster of 11 units, and you are using MUTOAs. How many MUTOAs are required for this application. - Answer-1 How many transition points can you install in a horizontal cabling run? - Answer-1 What color represents 1st level backbone cross-connect in a telecommunications room? - Answer-White What color represents the horizontal cabling cross-connect in a telecommunications room? - AnswerBlue Which class of administration of a SCS addresses infrastructure with multiple sight or campuses? - Answer-4 You are installing an outside plant cable into a building entrance. The customer is not concerned about aesthetic appearance. They just want the cheapest and most easily maintained option. What type of cable entrance would you use? - Answer-Aerial The main difference between an entrance facility and this room is that this room is generally considered to be floor-serving as opposed to building serving facilities. - Answer-TRWhat is the space defined as a case or housing dedicated to the telecommunications function and related support facilities. - Answer-TE What is the recommended minimum separation between telecommunications cable and electric motors exceeding 5 kilovolt-amperes? - Answer-48" What type of telecommunications space generally houses equipment that serves and entire building, campus, or customer? - Answer-ER What finished grade of plywood should be used in a telecommunications room? - Answer-A/C How far should toggle bolts be installed from the edge of a plywood backboard? - Answer-2" In a TR, on how many walls SHOULD cable tray be installed? - Answer-All Where should conduit ends be placed when a single piece of plywood is used as a backboard? - AnswerOn the left side The size of one rack unit is - Answer-1.75" The maximum length of flexible conduit is - Answer-20' The largest hand bender is what size? - Answer-1-1/4 trade size It is suggested that open cable supports be used for no more than how many cables? - Answer-50 What is the initial fill ratio factor of conduits when installing 2 cables? Assume straight runs with now degrees of bend. - Answer-31% Open top cable supports should be installed to maintain a minimum of ________________inches above ceiling tiles - Answer-3What is the point where the service provider network ends and the customer network begins? - AnswerDemarcation Point What is the maximum allowable horizontal cable length? - Answer-295' Which structured cabling topology places all network devices on one length of cable? - Answer-Bus
Document information
- Uploaded on
- April 18, 2024
- Number of pages
- 4
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers