• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 30 pages
Exam (elaborations)

Backflow Prevention Assembly Tester Exam V2 (Latest 2024/ 2025) Questions and Verified Answers| 100% Correct| Grade A

Document preview thumbnail
Preview 3 out of 30 pages

Backflow Prevention Assembly Tester Exam V2 (Latest 2024/ 2025) Questions and Verified Answers| 100% Correct| Grade A Q: When testing a SVB what is the firsrt test being performed (A) The air inlet opening point (B) The static pressure across the check valve (C) To verify the #2shut off hold tight (D) To check if the SVB hold water Answer: The static pressure across the check valve Q: When testing a PVB the air inlet opens upon closing the #1 shut off valve What is the most probable cause (A) Leaking #2 shut off valve (B) Leaking #1 shut off valve (C) Fouied air inlert (D) Fouied check valve Answer: Leaking #2 shut off valve Q: A 2" AVB when used on irrigation systemsterm-15 shall be instilled (A) 6" above all downstream piping (B) 18" above all downstream piping (C) 24" above all downstream piping (D) 27 3/4" above all downstream piping Answer: 6" above all downstream piping Q: What causes the relief valief valve to close on a RPZ? (A) Reilef valve spring pressure (B) Supply side water pressure (C) Pressure differential between Check #1 and Check #2 (D) All the above Answer: Supply side water pressure Q: When testing a RP instialled in vauil the relief valve opening point falls to zero What is most probabie cause (A) The relief valve is stuck shut (B) #1 check is fouled (C) the #2 shut off leaks by (D) Installed improperly Answer: Installed improperly Q: When field testing the DC the #1 check static differential pressure is found to be 0.0 psid What is the most probable cause (A) Fouied #2 Check (B) Leaking #2 shut off (C) Fouled #1 check (D) Leaking #1 shut off Answer: Fouled #1 check Q: The critical level for checking the air inlet of the PVB is (A) At the air inlet (B) At #1 shut off (C) At #1 test cock (D) At #2 shut off Answer: At the air inlet Q: The physical operation of a Hose Bibb Vacuum Breaker is classified as a type of (A) Dual check valve (B) Atmospherlc vacuum breaker (C) Pressure vacuum breaker (D) Doubie check backflow preventer Answer: Atmospherlc vacuum breaker Q: An oxygen deficient atmosphere has less than what precentage of oxygen (A) 19.50% (B) 10% (C) 21% (D) 24% Answer: 19.50 Q: The relief valve of a RP discharges in flow and non-flow condition What is the most probable cause (A) Fouied #1 check (B) Fouied #2 check (C) Fouied relief valve (D) Line pressure fiuctuation Answer: Fouied relief valve Q: A PVB may be installed with (A) A pump downstream (B) A water heater downstream (C) A shutoff valve downstream (D) An eievated storage tank downstream Answer: A shutoff valve downstream Q: The relief valve of a Reduced Pressure Principle Assmbly remains closed during normal operation due to (A) Supply side pressure (B) The relief valve spring (C) Zone pressure (D) All the above Answer: The relief valve spring Q: What would cause a continual flow of water from of water the air inlet of a PVB prior strting the field test


Document information

Uploaded on
April 5, 2024
Number of pages
30
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
nurse_steph
3.9
(1756)
Sold
9881
Followers
5155
Items
8194
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.