S95 PERSONAL EXAM | QUESTIONS & ANSWERS (VERIFIED) | LATEST UPDATE | GRADED A+
Which duties can an S-95 Certificate of Fitness holder perform? ANSWER: Visual Inspections Only - of fire alarm system components and smoke detectors What is the primary purpose of Fire Alarm Systems? ANSWER: To warn building occupants and transmit signals indicating a fire condition to the Fire Department via central station. What is a Fire Alarm signal? ANSWER: The signal initiated by a fire alarm initiating device such as a manual fire alarm pull station, smoke detector, water-flow switch, or any device in which their activation indicates presence of fire. What is a Supervisory Signal? ANSWER: A signal indicating that a system or device being monitored has been compromised or is in an abnormal state. Deeagles - Stuvia US Is the FDNY dispatched for Supervisory Signals? ANSWER: No. The Facility Manager should investigate and correct the supervisory condition indicated by the FACP. What is a Trouble Signal? ANSWER: A signal that indicates a fault with the fire equipment. It must have an audible signal, distinctive from alarm signals What is the maximum number of minutes that routine handling should take?-- from receipt of trouble signal by central station until initiation of the investigation by telephone. ANSWER: FOUR minutes Is the FDNY dispatched for Trouble Signals? ANSWER: No. Trouble Signals aren't indicative of a fire condition. What is an Acknowledge Switch (ACK) ? ANSWER: This switch/button is used to acknowledge alarm, supervisory, or trouble conditions. Why is an Alarm Silence Switch helpful after an evacuation - while the source of alarm is being investigated? Deeagles - Stuvia US ANSWER: This switch/button silences audible and visual devices (sirens, bells, gongs) so it's easier for Emergency Responders to communicate. Which switch/button is pushed once an alarm condition is cleared? ANSWER: The System Reset Switch Smoke Detectors should be cleaned not less than ANSWER: Once every six months How often should Analog Smoke Detectors be cleaned? ANSWER: One week from receipt of an indication that cleaning is needed. How often should Smoke Detectors be tested for smoke entry? ANSWER: Not less than once a year After activation, which type of heat detector self-restores? Which type doesn't? ANSWER: Fixed-Temperature heat detectors: Doesn't self -restore and requires replacement. Rate of Rise heat detectors: self-restore Fire Alarm Circuits' primary power source shouldn't generate electric power exceeding which voltage? ANSWER: 277/480 volt
Document information
- Uploaded on
- April 3, 2024
- Number of pages
- 14
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers