• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 6 pages
Exam (elaborations)

F-60 _Fire Guard for Torch Operations Practice Test with Complete Solutions

Document preview thumbnail
Preview 2 out of 6 pages

F-60 _Fire Guard for Torch Operations Practice Test with Complete Solutions

Content preview

F-60 _Fire Guard for Torch Operations Practice Test with Complete Solutions The fire watch for torch operations carried out in construction sites, in any building or structure, or on any rooftop shall be conducted by at leas t ____ F -60 fire guard. - CORRECT ANSWER 1 True or False? The COF holder must keep the certificate upon his or her person at all times while conducting the fire watch. - CORRECT ANSWER True Portable LPG containers that are more than ____ oz. must not be stored, handled, or used indoors or on the roof in the following occupancies: residential, factory, industrial, educational and institutional. - CORRECT ANSWER 16.4 Portable CNG containers that are more than ____ SCF must not be stored, handled, or used i ndoors or on the roof in the following occupancies: residential, factory, industrial, educational and institutional. - CORRECT ANSWER 8.7 What do LPG containers hold? - CORRECT ANSWER Liquefied petroleum gas. What do CNG containers hold? - CORRECT ANSWER Compressed natural gas. Torch operations are considered a type of ____ work. - CORRECT ANSWER Hot. Storing, using or handling any flammable gas, oxidizing gas, or oxygen and a flammable gas requires an FDNY _ ___. - CORRECT ANSWER Permit. Use of liquefied petroleum gas (LPG) on an occupied roof requires an affidavit from a licensed professional stating the roof is constructed of ____ material. - CORRECT ANSWER Non -combustible. Any single liquefied petroleum g as (LPG) container must not exceed ____ lbs in weight. - CORRECT ANSWER 100 Any single compressed natural gas (CNG) container must not exceed ____ standard cubic feet (SCF). - CORRECT ANSWER 381 What are the 3 types of FDNY permits for operations using l iquefied petroleum gases (LPG), compressed natural gas (CNG), or other flammable gas? - CORRECT ANSWER (1) Site -specific. (2) Citywide. (3) Transportation. What is a site -specific permit? - CORRECT ANSWER It authorizes the storage, handling or use of fl ammable gases and torch operations at a specific premises or location. What are the 2 types of site -specific permits? - CORRECT ANSWER (1) Permanent; valid for 12 months only. (2) Temporary; valid for 1 to 12 months. Normally, a hot work operation is is sued a ____ permit. - CORRECT ANSWER Temporary. What is a citywide permit? - CORRECT ANSWER It authorizes the storage, handling, use or selling of hazardous materials on a citywide basis (at one or more locations). What are 3 important restrictions of a citywide permit? - CORRECT ANSWER (1) The activity cannot exceed 30 calendar days. (2) All hazardous materials must be removed at the end of the workday. (3) The quantity of hazardous materials does not exceed 5 gallons of gasoline, or 250 gallons of any other flammable liquid, and 300 gallons of any combustible liquid. Periods of activity in excess of 30 calendar days at any one location shall require whi ch permit? - CORRECT ANSWER Site -specific. If the quantity of hazardous materials exceeds 5 gallons of gasoline, or 250 gallons of any other flammable liquid, and 300 gallons of any combustible liquid, a ____ permit shall be required. - CORRECT ANSWER Sit e-specific. What is a transportation permit? - CORRECT ANSWER It authorizes the transportation, pick up and delivery of hazardous materials. A transportation permit must be displayed on the ____. - CORRECT ANSWER Vehicle. All permits shall be readily av ailable on the premises for inspection by who? - CORRECT ANSWER The FDNY. What is a hot work program? - CORRECT ANSWER A program implemented by the responsible person to oversee hot work for the purpose of preventing fire. What is a hot work program auth orization? - CORRECT ANSWER A document signed and issued by the responsible person allowing hot work to be performed at the premises. It must be available for inspection by the FDNY during the work and for 48 hours after the work is completed.

Document information

Uploaded on
March 31, 2024
Number of pages
6
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Verifieddocs
3.8
(24)
Sold
125
Followers
87
Items
1544
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions