• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

Type B- TFM02 with complete solution Graded A+

Document preview thumbnail
Preview 2 out of 9 pages

T/F A three dimensional fire often involves static flammable liquid. - False. 3D fires involve flammable liquid in motion as well as both horizontal and vertical surfaces. Class A fire extinguisher are ok for ___________, ____________, ______________, and _______________. They offer the coating effects of dry chemicals. - wood, paper, some plastics, and textiles When should dry chemical stored pressure fire extinguishers be removed and replaced? - at their next 6 year maintenance or hydrostatic test interval Concerning the UL rating, B:C rating refers to... - the amount of sq footage an extinguisher covers T/F Class B fire extinguishers cannot handle flammable liquids. - False Employees must be trained in proper use of all portable fire extinguishers according to... - CRF29 Portable fire extinguishers need to be VISUALLY inspected at least ____________ according to ______________________. - Monthly, 29 CFR 1910.157 (e) (2) Which extinguishers should not be used for fire that involves live electrical equipment? - Class A/B extinguishers Water or steam fire extinguishers need to be discharged, disassembled, and inspected at least... - annually An extinguisher weighing over 40 lbs should be installed so the top is no more than __________ from the ground. - 3.5 ft What is the OSHA specified max travel distance to get to a Class B extinguisher? - 50 ft Dry chemical extinguishers require ________ to be emptied for maintenance. While, hydrostatic tests are every _________. - 12 years, 6 years A rated UL extinguisher is how many gallons of water? - 1.25 Class C fire extinguishers use _______________ _____________ extinguishing agents. - electrically nonconductive Cartridge operated water based portable extinguishers need hydrostatic testing every - 5 years When do Stored pressure type of extinguishers need INTERNAL examination? - never Extinguishers weighing 40 lbs or LESS must be installed so the top of the canister is no more than....... - 5 ft above the ground Class _______ extinguishers are for fires involving cooking media. - K What is the OSHA specified max travel distance for a Class A extinguisher? - 75 ft What is the proper UL rating for an extinguisher that is electrically energized equipped? - C Class ________ work on the principle of saponification. - K What type of fires involve a flammable liquid on a horizontal surface with the presence of a solid object creating a barrier? - Obstacle type fires Extinguishers must be installed ___________ from the ground. - 4 inches Where might Obstacle type fire take place? - in flammable liquid storage cabinets, dip tank process areas, ect. To make sure the pressure gauges of CO2 extinguishers are showing adequate pressure, what must you do? - must be weighed Wetting agent portable extinguishers must be hydrostatic tested every ___________. - 5 years When should leak tests be performed on stored pressure extinguishers? - after recharge How do you convert fire extinguishers from one type to another? - you don't When can remaining dry chemicals in a discharged extinguisher be used and under what circumstances? - only if checked for proper type, contamination, and condition. CLOSED RECOVERY system needs to be used! Under what circumstances do extinguishers not need any verification of service collar installed? #1 - #1 new extinguishers needing charge in the field How do you have an extinguisher converted to use a different type of extinguishing agent? - you don't When does the gauage used to set the regulated source of pressure need to be calibrated? - annually When does a pump tank calcium chloride based antifreeze extinguisher need to be recharged? - annually What is the OSHA specified max distance to a Class D extinguisher? - 75 ft When recharging, how should the amount of recharge agent be verified? - by weighing What type of extinguishers must have hydrostatic tests every 5 years? - Aqueous Film Forming Foam (AFFF) When should the wetting agent in stored pressure wetting extinguishers be replaced? - annually When should the premized agent in liquid charge AFFF and FFFP extinguishers be replaced? - every 3 years Under what circumstances do extinguishers not need any verification of service collar installed? #2 - #2 cylinder-operated extinguisher T/F You are free to mixmultipurpose dry chemicals with alkaline based dry chemicals. - False What circumstance should be avoided? - subsurface injection of wet chemical extinguishing agents into hot cooking media T/F You should NEVER place extinguishers in cabinets or wall recesses. - False How often must CO2 portable extinguishers go through hydrostatic testing? - 5 years What are special hazards? - pressurized gas fires and pressurized flammable liquids What type of extinguishers with agents other than dry chemicals are not very effective on special hazards? - type B How do you adjust regulators that are utilized on wheeled fire extinhuishers? - Do not attempt


Document information

Uploaded on
March 30, 2024
Number of pages
9
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Ascorers
4.7
(1162)
Sold
1595
Followers
73
Items
3777
Last sold
17 hours ago

Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.