100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ABYC Systems Certification Exam Review Polyethylene

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
16-03-2024
Written in
2023/2024

Polyethylene - ANSWER What is the most often used materials for potable water systems? 1. Copper Alloys (incl. bronze, brass and nickel-copper) 2. AISI Type 300 series stainless steel 3. Glass-lined metal 4. FDA approved plastic 5. FDA approved rubber - ANSWER Name 5 materials allowable for contact use in potable water systems: Siphon Break - ANSWER What device can be used to separate potable water from other water systems? Accumulator Tank, after pump/filter and before check-valve - ANSWER What is the device used to maintain a stable pressure and minimize pump cycling, and where should it be located? 175% - ANSWER At what what percentage of nominal working pressure shall the relief valve be set? No, typically these are too high (up to 400% of nominal pressure) - ANSWER Is a standard household type relief valve acceptable for hot water tanks? nominal working pressure, not to exceed 80 PSI - ANSWER For the pressure reducing valve and check valve installed after a shore water connection, what is the maximum allowable pressure? overboard - ANSWER Where shall the storage tank be vented? 3 PSI or mnfg's maximum, which ever is greater. - ANSWER What is the maximum allowable pressure to which the storage tank and vent system be subjected? -40 °F to +140 °F - ANSWER What temperate range is required for pumps to be able to tolerate exposure? 257 F - ANSWER When operating at an ambient temperature of 140 F, what is the max allowable surface temperature of a pump? True - ANSWER Potable water systems must be equipped with a drain. T or F? False - ANSWER Storage tank inlet may also serve as the tank vent. T or F? True - ANSWER Storage tank inlet caps must be retained to prevent loss. T or F? True - ANSWER Storage tanks must be equipped with a vent. T or F? True - ANSWER Storage tank vent may be used for filling purposes. T or F? At least 1.5X the pressure exerted by the distance f

Show more Read less
Institution
ABYC Marine Electrical
Course
ABYC Marine Electrical










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ABYC Marine Electrical
Course
ABYC Marine Electrical

Document information

Uploaded on
March 16, 2024
Number of pages
25
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • abyc

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lecchris West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
40
Member since
2 year
Number of followers
15
Documents
3203
Last sold
3 weeks ago
LECCHRIS

3.8

6 reviews

5
2
4
1
3
3
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions