• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 20 pages
Exam (elaborations)

Api 653 Formulas All Answers Correct

Document preview thumbnail
Preview 3 out of 20 pages

API 653 FORMULAS ALL ANSWERS CORRECT 1.5-4.0 mils Linings- Typically anchor profile of steel surface required for the installation of a tank bottom lining 652: 7.5 Welds- Maximum undercut of a vertical weld & nozzle weld 650: 8.5.2.b Welds- Maximum undercut of a horizontal weld 650: 8.5.2.b 1/32" Welds- Maximum diameter of a surface porosity cluster 650: 8.5.2.c 1/64" 3/32" Weld Qualification- Max allowed discontinuity in a bend test IX: QW-163 1/8" Nameplates- Minimum size of name plate letters 650: 10.1.1 & 653: 13.1.1.1 5/32" Bottoms- Minimum external projection of bottom plate on an existing tank (from toe of shell-to bottom FW) 653: 4.4.5.7 3/8" Reconstruction- Max amount of peaking allowed in vertical welds 653: 10.5.4 1/2" Shell Calcs- When calculating tmin for shell LTA, minimum distance away from a weld where "E" is always 1.0 653: 4.3.3.1 (definitions) 1" or 2t 1" Shell Patch- Minimum overlap of shell lap-patch used to cover a hole (edge of hole to edge of patch) 653: 9.3.2.3 NDE- When performing a PT examination, minimum distance to clean beyond the area to be examined V: T-642.b 1" NDE- When performing a MT examination, minimum distance to clean beyond the area to be examined V: T-741.1.b 1" Reconstruction- Maximum amount of banding allowed in a horizontal weld 653: 10.5.5 1" Bottoms- Minimum overlap required for single-welded lap joints 650: 5.1.3.5 Bottoms- Minimum external projection of bottom plate on a new tank 650: 5.4.2 1" 2" Vacuum Box- Minimum overlap of previously test surfaces when using a vacuum box 650: 8.6.5 2" 2" Bottom Patch- Minimum overlap of bottom lap-patch fillet weld to the nearest existing bottom weld 653: Fig. 9.13 2" Bottom Patch- Minimum distance bottom lap-patch fillet weld to the nearest existing bottom weld 653: Fig. 9.13 Shell Patch- Minimum radius of a shell lap-patch 653: 9.3.1.4 2" Reconstruction- If reusing bottom plates, minimum distance to cut from existing bottom welds (if plates are not deseamed) 653: 10.3.2.1 2" Reconstruction- If reusing roof plates, minimum distance to cut from existing roof welds (if plates are not deseamed) 653: 10.3.4.1 2" Shell Pitting- Maximum allowed vertical length of pits on a tank shell 653: 4.3.2.2.b 2" in 8" line Bottom Pitting- Maximum allowed length of pits in the critical zone that can be repaired by weld buildup 653: 9.10.1.6.a 2" in 8" arc Bottoms- Radial length of critical zone measured from shell 653: 3.10 Bottoms- Suggested sand pad thickness 650: B.3.2 3-4" 3" Welds- Minimum distance between clusters of surface porosity 650: 8.5.2.c 4" Shell Patch- Minimum dimension of a shell lap-patch 653: 9.3.1.7 4" Shell Patch- Minimum radius of a shell flush-patch 653: Fig. 9.1 "R" dimension 6" Shell Calcs- When calculating tmin for shell LTA, minimum distance away from the rivet where "E" is always 1.0 653: 4.3.4.1 6" Bottom Patch- Minimum size of bottom lap-patch that does NOT cross a bottom seam 653: 9.10.1.1.b 6" Bottom Patch- Minimum distance between a bottom lap-patch and the shell for patches that do NOT extend to the shell 653: Fig. 9.13 or 9.10.1.2.b 6" Reconstruction- If reusing shell plates, minimum distance to cut from existing shell welds (if plates are not deseamed) 653: 10.3.3.1.c 6" RT- Minimum diagnostic length of a RT for vertical or horizontal welds 650: 8.1.2.8 653: 12.2.1.7 6" Weld Qualify- Minimum weld length when qualifying a welder with RT/UT using a coupon or 1st production weld IX: QW-302.2 IX: QW-304.1 6" 6" Weld Qualify-Minimum weld length when qualifying a welding operator with RT/UT of a test coupon IX: QW-302.2 Shell Patch- Minimum distance a lap patch shall overlap a shell weld 653: 9.3.1.5 Corrosion- Area to dig when checking for soil-to-air corrosion 575: 8.2.10 NDE- Distance of eye-to-part to count as visual exam 577: 9.3.1.e Vacuum Box- Typical size of a vacuum box 650: 8.6.1 6" 6-12" 6"-24" 6" x 30" Shell Patch- Minimum dimension of a shell flush-patch 653: 9.2.2.1 12" Bottoms- Minimum dimension that a 3-lap joint can be from: other 3-laps, the shell, or annular plate joints 650: 5.1.5.4.2 12" Bottom Patch- Minimum dimension of bottom lap-patch that crosses a bottom seam 653: 9.10.1.1.a 12" Foundations- Suggested height above grade for new tank bottoms 650: B.3.1 12" Shell Patch- When adding a shell flush-patch that extends to a horizontal shell weld, minimum distance to cut the horizontal weld past the new vertical welds 653: Fig. 9.1 note 2 12" 12" Shell Patch- Dimension of a shell flush-patch that is considered either a major repair or alteration 653: 3.20.c Definition- Dimension of a shell vertical weld if repaired or replaced is considered a major repair of major alteration 653: 3.20.e 12" Bottom Patch- Maximum width of bottom patch in the critical zone 653: Fig. 9.13 note 3 24" Bottoms- Minimum radial width of annular plate (distance between shell and nearest bottom fillet weld) 650: 5.1.5.4.3 & 5.5.2 24" NDE- Maximum distance of eye-to-part to count as visual exam 575: 9.2.1 24" Hot Tap- Minimum height of liquid above new nozzle during the hot tap operation 653: 9.14.1.2 36" Weld Qualify- minimum weld length when qualifying a welding operator with RT/UT of first production weld IX: QW-305.1 36"


Document information

Uploaded on
March 12, 2024
Number of pages
20
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CertifiedGrades
3.9
(38)
Sold
149
Followers
61
Items
8729
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.