Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 15 pages
Exam (elaborations)

Contractor's License Exam Questions With 100% Correct Answers | Verified | Updated 2024

Document preview thumbnail
Preview 2 out of 15 pages

Contractor's License Exam Questions With 100% Correct Answers | Verified | Updated 2024 Attachments to structural members The edges of lugs brackets, rivets and bolt heads attached to structural members shall be permitted to extend to within 1 inch of the surface of the fire protection Parapet construction The height of the parapet shall not be less than 30 inches above the point where the roof surface and the wall intersect. Combustible framing in fire walls Adjacent combustible members entering into a concrete or masonry fire wall from opposite sides shall not have less than a 4 inch distance between embedded ends. Concealed sleeper spaces spaces under floors that are filled fire resistant material; open spaces will will not exceed 100 sq feet Fire alarm height The height of the manual fire alarm boxes shall be not less than 42 inches and not more than 48 inches Manual fire box color red Size of doors minimum clear width of 32 inches and height no less than 80 inches Stairways width and capacity minimum width shall be not less than 44 inches Stairway headroom stairway headroom clearance of not less than 80 inches measured from a line connecting the nosings. riser height 4-7 tread depth 11 inches minimum Dimensional uniformity (stairs) the difference between the greatest and the smallest stair shall not exceed 3/8 inch Handrails Stairways shall have handrails on each side and adequate in length Handrail height 34-38 inches HANDRAIL CLEARANCE FROM THE WALLS 1.5 inches guards Guards shall be located along open-sided walking surfaces more than 30 inches off the ground Guard Height shall not be less than 42 inches Guard opening limitations no openings large enough to allow a 4 inch ball to pass through if so a curb is required Emergency Escape and Rescue Opening shall have a minimum net clear opening of 5.7 square feet Emergency Escape and Rescue Opening dimensions height 24 inches by 20 inches wide Under floor ventilation crawl spaces shall be provided with ventilation openings in the foundation walls Openings for under floor ventilation shall not be less than 1 square foot for each 150 square feet of crawl space area Crickets and saddles a cricket and saddle shall be installed on the ridge side of any chimney or penetration greater than 30 inches measured perpendicular to the slope Asphalt shingles attachment Shingles shall have a minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle. Asphalt shingles underlayment For roof slopes of four units vertical in 12 units horizontal (33-percent slope) or greater underlayment shall be one layer applied starting from the eave lapped 2 inches Asphalt shingle slope Can only be used on a slope of 17% or greater Base and cap flashing Base flashing shall be of either corrosion-resistant metal of minimum .019 inc thickness or mineral surfaced roll roofing minimum 77 pound Drip edge A drip edge shall be provided at eaves and rake edges of shingle roofs. They will be fastened at a maximum of 12 inches on center. Flashing The valley flashing shall extend at least 11 inches from the center line each way and have a splash diverter rib not less than 1 inch high Metal roof shingles deck slope shall not be installed on roof slopes below 3/12 (25%) slope mineral surface roll roofing deck slope shall not be installed on roofs with a slope below 1/12 (8%) mineral surface valley (flashing) shall be a minimum of 15 inches wide Wood shingles Deck requirements sheathing boards shall not be less than 1 inch by 4 inch wood shingles deck slope wood shingles shall be installed on a slope not less than 3/12 (25%) Live Load grab bars, shower seats and benches shall resist a single concentrated load of 250 pounds Special inspections and tests the owner shall employ one or more special inspectors to provide inspections during construction on the types of work listed in accorda


Document information

Uploaded on
February 24, 2024
Number of pages
15
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar
3.7
(140)
Sold
716
Followers
178
Items
27421
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.