NFPA-99: Practice Test Questions With Complete Solution Graded A+

Document preview thumbnail
Preview 2 out of 13 pages

NFPA-99: Practice Test Questions With Complete Solution Graded A+ Under which of these conditions shall the instrument Air Reserve header cylinders be permitted to be stored with the instrument air compressor? A) the mechanical equipment room does not contain a boiler. B) the medical air compressors are in the same room. C) the only motor-driven machinery in the room is for instrument air equipment. D) the room is secured with lockable doors. - correct answerC) The only motor-driven machinery in the room is for the instrument air equipment Riser valves are those valves located where? A) adjacent to the main riser downstream of any zone valve. B) anywhere in the lateral branches of the piping system. C) in the mainline adjacent to the base of the riser. D) in the riser adjacent to the mainline. - correct answerD) In the riser adjacent to the main line When is the initial pressure test conducted by the installer? A) after blowdown of the distribution piping. B) after installation of alarm sensors. C) before blowdown of distribution piping. D) before installation of station rough in assembly. - correct answerA) After blow-down of the distribution piping. In those portions of systems intended to handle oxygen at pressure greater than 350 psi the inter connecting hose shall not contain what materials? A) brass. B) copper C) polymeric D) stainless steel - correct answerC) Polymeric The tool shown here allows the installer to mechanically limit the makeup depth of the fitting to be brazed. Under what condition is this method permitted for the installation of medical gas piping? A) only on final line connectors. B) only on vacuum systems. C) where only B cup 5 brazing rod is used D) where the limited makeup depth is not less than minimum cut depth her ANSI / ASME recommendations - correct answerD) Where the limited makeup depth is not less than minimum cup depth current ANSIASME recommendation What is the standard gauge pressure for nitrogen gas service? A) 15 - 30 B) 50 - 55 C) 162 185 D) it varies with system type. - correct answerC) 50 - 55 psi What is a NFPA 99 requirement for labeling of pipes in medical gas system? A) color coding B) fixed label with C) label shall wrap completely around pipe. D) reflective label - correct answerA) Color coding A wireless communication device is employed in a medical gas or vacuum warning system. what type of supervision is required for this device? A) a visual indicator Shelby located in maintenance officer or engineering department. B) this device shall be installed at the medical gas or vacuum source. C) this device shall be located at nurses station. D) this device will be supervised such that failure communication shall initiate an alarm. - correct answerD) This device will be supervised such that failure of communication shall initate an alarm In a facility where Medical Gas vacuum systems are present and the failure of such equipment or systems is likely to cause any major injury or death to patients or caregivers this system shall be designed to meet which category requirements? A) 1 B) 2 C) 3 D) 4 - correct answerA) category 1 A faculty is in the planning stages of installing an emergency oxygen service connection (ESOC). How many feet is the minimum amount of clearance required around this connection? A) 1 foot B) 3 feet C) 5 feet D) Clearance must be 1-1/2 times the width of the auxiliary. - correct answerB) 3 feet Wooden rack for cylinder storage may be permitted under which conditions? A) the wooden must be painted. B) they are permitted with no set conditions . C) they must be located in an area with fire suppression system. D) Wooden racks are no longer permitted - correct answerD) Wooden racks are no longer permitted If nonmetallic flexible connectors is being used in a category 1 healthcare faculty to connect to the manifold to the gas distribution piping what is the maximum length permitted for the flexible connectors? A) 2.5 feet B) 5 feet C) They shall be no longer necessary D) the use of flexible connectors is not permitted. - correct answerC) They shall be no longer necessary What type of copper tube hanger shall be used for potentially damp locations? A) carbon steel B) copper coated C) Plastic coated or insulated with material that will be non-absorbent or D) solid copper - correct answerC) Plastic coated or insulated with material that will be non-absorbent


Document information

Uploaded on
February 24, 2024
Number of pages
13
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Examset
4.0
(1)
Sold
4
Followers
2
Items
456
Last sold
11 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.