MN Boilers test practice (special) The dial on a steam gauge on a low-pressure boiler must be graduated from _ to _ times the maximum allowable working pressure - correct answer 1 1/2 to 2 What is the minimum size of pipe diameter that may be used to attach a steam gauge to a steam boiler? - correct answer 1/4 inch Steam boilers are designed to operate at or below what PSI? - correct answer 15 Liquid Boilers are designed to operate at or below what PSI? - correct answer 160 What is the term of the area of the boiler that has water/liquid on one side and the heat source on the other? - correct answer Heating Surface What type of safety valve is required on a steam boiler? - correct answer Spring-Loaded When the heating surface of a _____-pressure boiler exceeds ____ square feet, the minimum number of safety valves is what? - correct answer High, 500, 2 or more 4 1/2 inches is the maximum size safety valve that may be installed on on a _________ boiler - correct answer low-pressure The maximum size safety relief valve on a low-pressure boiler is what? - correct answer 4 1/2 inches How many Kw equals 1 boiler horsepower? - correct answer 10 10 Kw is equal to how much boiler horesepower? - correct answer 1

Content preview

MN Boilers test practice (special)

The dial on a steam gauge on a low-pressure boiler must be graduated from _ to _ times the maximum
allowable working pressure - correct answer 1 1/2 to 2



What is the minimum size of pipe diameter that may be used to attach a steam gauge to a steam boiler?
- correct answer 1/4 inch



Steam boilers are designed to operate at or below what PSI? - correct answer 15



Liquid Boilers are designed to operate at or below what PSI? - correct answer 160



What is the term of the area of the boiler that has water/liquid on one side and the heat source on the
other? - correct answer Heating Surface



What type of safety valve is required on a steam boiler? - correct answer Spring-Loaded



When the heating surface of a _____-pressure boiler exceeds ____ square feet, the minimum number of
safety valves is what? - correct answer High, 500, 2 or more



4 1/2 inches is the maximum size safety valve that may be installed on on a _________ boiler - correct
answer low-pressure



The maximum size safety relief valve on a low-pressure boiler is what? - correct answer 4 1/2 inches



How many Kw equals 1 boiler horsepower? - correct answer 10



10 Kw is equal to how much boiler horesepower? - correct answer 1

, What does ASME stand for? - correct answer American Society of Mechanical Engineers



What does NBIC stand for? - correct answer National Board Inspection Code



What kind of stamp is needed in order to legally be able to weld on a boiler? - correct answer "R"



In the state of Minnesota, how often do Boilers get inspected by an insurance company or a State Boiler
Inspector? - correct answer Yearly



How many square feet is considered equivalent to 1 boiler horsepower? - correct answer 10



What must be easily accessible/in view in the boiler room? - correct answer Boiler log, certificates of all
employees qualified to work on boiler



What is the minimum size pipe that may be used to connect a water column to high pressure boilers?
(other than miniature boilers) - correct answer 1 inch



Water columns of steel must be used if pressure is over _____ psi - correct answer 350



An outside _____ and ______ _______ valve may be used between a high-pressure steam boiler and the
water column - correct answer screw, yolk, gate



How must water column connections be at right angle turns to enable cleaning and inspections? -
correct answer Must be a cross instead of an elbow.



_____ is the minimum size drain required on a water column - correct answer 3/4 inch



If the water gauge glass became plugged or broken on a steam boiler, the boiler could temporarily
operate using the _____? - correct answer gauge-cocks(try-cocks)



A ______ cock used on a steam gauge must be a _ or ____ valve - correct answer Stop, T, lever

Document information

Uploaded on
February 11, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$22.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclass
3.4
(11)
Sold
28
Followers
12
Items
4570
Last sold
7 months ago


Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions