The effects of main magnetic field inhomogeneities on the FID signal are corrected for in a Spin-echo
sequence by applying a second radio-frequency pulse. The flip angle of this radio-frequency pulse is:

180 degrees

Of the following statements, which describes part of the basic MR imaging process?

Radio-frequency signals interact with hydrogen protons

Which type of electromagnetic coils correct inhomogeneities in the main magnetic field?

Shim coils

Immediately after an initial 90 degree radio-frequency pulse is turned off, the hydrogen protons will
begin to:

Dephase

Tissues that are very efficient at Spin-lattice interactions near the Larmor frequency, such as fatty
tissues, should have:

Low T1 values and produces hyperintense signals

T1 is the measurement of time for the longitudinal component of the net magnetization vector to
recover what percentage of its original value after the application of a 90 degree radio-frequency pulse?

63%

The tissue characteristic which depends more on the state (solid, liquid, gas) of a tissue than any other
factor is:

T2 effects

The basic process of MR signal generation contains two basic steps, they are:

Stimulation and relaxation

The T1 Process is also known as:

Spin-Lattice

,The T2 process is also known as:

Spin-Spin

Once in the main magnetic field, a majority of hydrogen protons will align themselves:

Parallel to B0

Magnetic resonance imaging is derived from the process known as:

Nuclear magnetic resonance

The tissue characteristic that depends heavily on the relative content of fat molecules and free water is:

T1 effects

Which type of receiver radio-frequency coil is placed close to the patient's body for the purpose of
imaging superficial anatomic structures?

Surface coils

An equation derived to predict the MR signal intensity of a particular tissue as a result of a spin-echo
pulse sequence is the:

Larmor equation

Which equation is true of the relaxation process?

Without the effects of T2 star, T2 decay continues

Because of the spinning motion of the hydrogen proton it has the same properties as a bar magnet. The
hydrogen proton's spinning motion gives it a:

Magnetic moment

On a proton density image, two types of tissue that contain very low concentrations of hydrogen appear
very hypointense are: (RESEARCH THIS)

Cortical bone and lung (RESEARCH THIS)

Magnetic susceptibility is defined as: (RESEARCH THIS)

Tendency of a substance to attract or repel magnetic lines of force which is decided by the magnetic
properties of its electrons (RESEARCH THIS)

In comparison to computed axial tomography, an advantage of MR is:

Superior soft-tissue contrast resolution

Fast transition phenomenon and entry phenomenon are theories that explain which of the following
tissue characteristics?

Velocity effects

,In a loop of conductor in which an electric current is introduced and maintained, a magnetic field will be
produced in the center perpendicular to the flow of electric current. This is called:

Faraday's Law

Which type of MRI magnet has attainable field strengths of 0.35 Tesla to 3 Tesla for clinical use in the
U.S.A, and higher strengths elsewhere and in research?

Superconcuctive

The purpose of the first use of metal ions in MRI enhancement, like gadolinium, is to

Decrease relaxation time for H(ydrogen) in tissues

A permanent magnet requires liquids helium and liquid nitrogen on a dedicated cooling system

False

Which type of MRI magnet is made up of naturally ferromagnetic material

Permanent

MRI magnets that must have a dedicated, special cooling system due to heat produced by large currents
( approx. 100-150 amps) are

Resistive

Substances which have magnetic properties of their own, such as methemoglobin or gadolinium, cause
shortened T1 and T2 values for tissues in their vicinity are

Paramagnetic

Information acquired when you increase or decrease the frequency of the RF pulse of the Gs, .....

To be continued.......

In MRI substances respond to a specific radio frequency which is known as

Resonance frequency

Effects associated with gradient magnetic fields in MR systems are

A)Tissue hearing and cataract formation

Possible effects of exposure to the transient radio frequency signals are

B) tissue hearing and cataract composition

Possible effects of exposure to the main magnetic field are

D) magnetophosphenes, bones healing faster, cardiac fibrillation

Relaxation from Resonance Begins set the time

C) B sub 1 isturned off

, In 1990 Lauffer described two types of contrast media, the mechanism of the T1 agent is to

D) decrease T1 relaxation time, this emitting high signal.

For the following spin echo protocol: fov 320/TR 500/ TE 25/ slice thickness 5mm/ slice gap 1 mm/ NEX
4/ matrix 192. Increasing the Field of View will

Increase SNR

What factor, in spatial localization, does the slope of the slice select gradient?

Slice thickness

What is the gyro-magnetic ratio of hydrogen

42.58MHz

For the followong spin echo protocol.
FOV 320/ TR 500/ TE 25/ slice thickness 5mm/ slice gap 1mm/ NEX 4/ matrix 192. Decreasing slice
thickness will

Decrease SNR

The Process of relaxation begins when

B1 is turned off

A sinewave is a symbol used to measure electromagnetic energy. A sinewave's two components of
measure are:

Wavelength and frequency

Magnetic fields have direction which are usually designated as north and south, therefore magnetic
fields are described as:

Dipoles

At any one time, human body tissue, in general, is made up of 50-90%:

H(Hydrogen)

Once the net magnetization vector (NMV) has moved away from equilibrium the following will occur:

The transverse component will increase

The T1 process is also known as:

Spin-Lattice

Which of the following is the Larmor equation?

W0=Y+B0

The mechanism of T2 contrast enhancement agents is to:

Document information

Uploaded on
January 16, 2024
Number of pages
68
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Drmserpi
4.6
(217)
Sold
98
Followers
32
Items
2366
Last sold
2 weeks ago

Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions