• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 6 pages
Exam (elaborations)

CAOHC Exam Study

Document preview thumbnail
Preview 2 out of 6 pages

CAOHC Exam Study Unit of measurement for frequency (pitch) - ANS Hertz (Hz) Unit of measurement for intensity (loudness) - ANS Decibel (dB) Risk of damage from noise - ANS How loud (intensity) and how long (duration) Steady-state or continuous noise, e.g. generator - ANS Lasts 1 second or longer Impulse or Impact noise, e.g. gunfire or nail gun - ANS Lasts less than one second Parts of the outer ear - ANS Pinna and external auditory canal Parts of the middle ear - ANS Tympanic membrane, ossicles, eustachian tube Eustachian tube (auditory tube) - ANS Tube connecting the middle ear to the pharynx and equalizes middle ear space with atmospheric pressure Conductive HL occurs here - ANS Outer or middle ear Sensorineural hearing loss - ANS Hearing loss resulting from damage to the inner ear (cochlea) or the auditory nerve Noise-induced hearing loss (NIHL) - ANS Condition caused by the destruction of hair cells, the organs responsible for hearing, as a result of sounds that are "too long, too loud, or too close"; a sensorineural hearing loss Mixed hearing loss - ANS Combination of conductive and sensorineural types in the same ear Middle ear bones (ossicles) - ANS Malleus (hammer), incus (anvil), stapes (stirrup) Possible early symptoms/signs of noise induced hearing loss - ANS Tinnitus; difficulty understanding in presence of background noise; read visual cues Auditory effects of noise - ANS NIHL; tinnitus; hyperacusis Non-auditory effects of noise - ANS annoyance sleep disturbance attention motivation stress reactions cardiovascular problems endocrine problems 3 foot rule - ANS Good rule of thumb to recognize hazardous noise exposure levels/situations: the rule is: if you have to shout at arms length (~3ft), in order to be understood over the background noise, then you're likely exposed to hazardous noise levels & should be wearing hearing protection to prevent NIHL OSHA (Occupational Safety and Health Administration) versus National institute of Occupational Safety and Heath (NIOSH) - ANS OSHA enforces regulation and NIOSH recommends best practice based on science and research Sound pressure level (SPL) versus hearing level (HL) - ANS SPL describes noise measurements taken with a sound level meter or dosimeter; HL describes Threshold levels obtained with an audiometer; 0 dB HL is not equal to 0 dB SPL Noise Dosimeter - ANS A sound measurement device used to record the amount of sound exposure over an extended period of time (usually a work day) Personal vs. Area Sound level meter - ANS Uses a microphone to sense pressure variations in sound waves; the meter converts those pressures directly into decibels; provides a noise measurement that is a snapshot in time. Time Weighted Average (TWA) - ANS An evaluation of exposures that is time-weighted over an established period. It allow the exposure levels to be averaged generally over an eight-hour time period. OSHA exchange rate - ANS 5 dB; for every 5 dB you go over the PEL of 90dBA TWA you half the allowable time of exposure OSHA Action Level for noise - ANS 85dBA TWA Sound Level Meter A-weighted Scale - ANS OSHA requires this scale as it resembles how the human ear responds to sound (humans hear best from 500 Hz to 4000 Hz Human Frequency Response at Birth - ANS 20 Hz to 20,000 Hz (20 kHz) Human speech frequency range - ANS 250 Hz to 4000 Hz Elements of a Hearing Conservation Program - ANS Noise hazard assessment; engineering/administrative controls; annual hearing monitoring; annual training/education; hearing protection; recordkeeping OSHA Noise Amendment - ANS 29 CFR 1910.95 Hughson-Westlake Procedure - ANS Common procedure for obtaining threshold; the audiologist decreases stimulus intensity by 10 dB with a (+) response and increases by 5 dB with a (-) response Hearing threshold level - ANS Lowest intensity level responded to at least 50% of the time Excessive noise levels will impact these test frequencies during a hearing exam - ANS Low frequencies e.g. 500 Hz First frequency always tested on an occupational hearing exam - ANS 1000 Hz 1000 Hz retest - ANS Done as a validity check on first ear tested; thresholds should be within 5dB or should reinstruct patient and start test over Presbycusis - ANS A gradual loss of sensorineural hearing that occurs as the body ages Professional Supervisor In a HCP - ANS Responsible for oversight of Audiometric testing; reviews problem audiograms; must be an audiologist or physician Elements of a Hearing Conservation Program - ANS Mandatory and includes: exposure monitoring, audiometric testing, hearing protection, employee training, record keeping, and program evaluation Noise Controls - ANS At the source (preferred), along the path, at the receiver Industrial Hygienist - ANS Responsible for assessment of hazards that may affect workers as well as hazards that may impact the community. NRR - ANS Noise Reduction Rating; number determined in a laboratory Hearing protection derating - ANS OSHA recommends to reduce NRR in half Hearing protection types - ANS Noise reduction devices worn over the ear (noise muffs) or inside the ear canal (earplugs) in work or recreational settings with high noise levels Best hearing protection - ANS The one that is worn (consistently and properly) Dual hearing protection NRR - ANS After derating add additional 5dB of protection Inverse square law for noise - ANS For every doubling of distance away from a noise source you reduce the level by 6 dB Noise doubling rule - ANS If you add two identical noise sources you add 3dB to the Level (100 dB + 100 dB = 103 dB) Administrative noise controls - ANS Changes made by employer such as changing work schedules to reduce noise hazard risk to employees OSHA standard threshold shift - ANS 10dB average change at 2000 Hz, 3000 Hz, and 4000 Hz, when compared to a baseline , in one or both ears OSHA Recordable Standard Threshold Shift for Hearing Loss - ANS 3 criteria: 10dB average shift at 2, 3, and 4kHz, compared to baseline, AND 25 dB average HL at 2, 3, and 4 kHz in the same ear on current audiograms, AND determined to be work-related Collapsing ear canal - ANS Occurs naturally in some individuals during audiometric testing-earphones cause auricle to move forward collapsing the canal and causing an artificial hearing loss; Insert earphones should be used Cochlea - ANS A coiled, bony, fluid-filled tube in the inner ear through which sound waves trigger nerve impulses; damage from hazardous noise occurs here. Microprocessor audiometer - ANS Automated computer controlled audiometer Tinnitus - ANS A jingling; a ringing or buzzing in the ear Type of hearing test done by a certified occupational Hearing conservationist (COHC) - ANS Air Conduction Pure Tone Threshold Test Hearing Threshold Level (HTL) are recorded on this - ANS Audiogram (can be serial or graphic) Baseline Hearing Test Must Be Done Within - ANS 6 months of starting employment (exception for mobile vans is up to 1 year) Type of Hearing Loss that is treatable (medically or surgically) - ANS Conductive hearing loss Temporary Threshold Shift (TTS) - ANS Brief exposure to intense noise that will ordinarily recover with auditory rest Hearing Thresholds Tested are: - ANS 500, 1000, 2000, 3000, 4000, and 6000 Hz; 8000 Hz is optional but recommended. Audiometric zero is: - ANS 0 dB HL; this is not an absence of sound HL scale has been normalized to healthy adult hearing Vertical axis on a graphic Audiogram shows this: - ANS Intensity levels which are measured in Decibels (softest at the top, loudest at the bottom) Horizontal axis on a graphic Audiogram shows this: - ANS Frequencies which are measured in Hertz (low to high going from left to right) Hearing Baselines are reestablished when you have an STS because: - ANS You don't want to identify the same shift each ear #Days to notify individual of an STS in writing - ANS 21 days OSHA versus NIOSH Noise Permissible Exposure Limit (PEL) - ANS 90 dBA PEL for OSHA; 85 dBA PEL recommended by NIOSH OSHA recommendations for Audiometric Records - ANS Maintain for duration of employment; NIOSH recommends duration of employment + 30 years Sound Level Meter Microphone Type Required by OSHA - ANS Minimum of Type 2 microphone Formable Earplugs are: - ANS Disposable when no longer return to shape and soiled Pre-formed earplugs: - ANS Can be washed with mild soap and water and reusable Noise muff cushions - ANS Should completely cover ear and seal against the face; cushions should be replaced when damaged and no longer seal effectively. Hearing Aids and Hearing Test - ANS Tests are to be done without hearing aids Function of the Outer Ear - ANS Collecting sound and sending it to the eardrum through the auditory canal Function of the Middle Ear - ANS Amplification of sound; lever action of the ossicular chain and the mismatch in size of eardrum and oval window amplify sound about 10 times Function of the Inner Ear - ANS Convert mechanical sound waves to neural impulses that can be recognized by the brain for hearing and balance This type of hearing loss is treatable - ANS Conductive hearing loss When sound presented to the poorer ear crosses through the skull and is picked up by the better ear, this phenomenon is referred to as: - ANS Crossover The Action Level for OSHA and NIOSH is: - ANS 85 dBA TWA Weighting scale required by OSHA for Hearing Conservation Program Noise Assessments: - ANS A weighted scale; response resembles how the human ear responds to sound (humans hear best from 500-4000 Hz) This weighting scale is best for determining hearing protection attenuation - ANS C weighted scale; has a flat response with all frequencies equally weighted This Hearing Conservation Regulation is the minimum standard - ANS OSHA Noise Amendment Best audiometer for testing multiple stations - ANS Microprocessor Audiometer Best audiometer for testing difficult-to-test patients - ANS Manual Audiometer Calibration of audiometer performed daily with a electroacoustic simulator or human ear is called a: - ANS Biologic calibration A check of audiometer performed daily to ensure there are no intermittent problems with hardware is called a: - ANS Functional Check


Document information

Uploaded on
December 7, 2023
Number of pages
6
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
161
Followers
38
Items
6357
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.