Systems Verification BICSI Final
Cross Connects, Backbone Cabling, and Administration - Answer- Administration systems include requirements for; identifiers - that serve to locate the element record and administration scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, spreadsheets, database programs, or computer programs specially designed for that purpose, and labeling - with a variety of methods to display identifiers for the buildings, pathways, spaces, cabinets, racks, cabling, connectors, the choice of material, fastening method, environmental, performance, and security issues. Common methods for displaying identifiers include bar codes, graphics, labels, tags, and electronic identifiers There are four classes of administration: Class 1 - 1 ER which is the only telecommunications space on the site Class 2 - 2 or more telecommunications spaces in a building Class 3 - Multiple buildings at a single site Class 4 - Multiple sites or campuses Data Centers - are buildings or portions of a building whose primary function is to house a computer room, including the data center electrical rooms, mechanical rooms, storage rooms, staging rooms, operations and command center, and other spaces whose primary functions are to support the computer room. For redundancy, in accordance with ANSI/BICSI-002 stamdards, classes of Data Centers have been established. Class 0 - a single path data center that meets the minimum requirements but cannot be classified as Class 1 or higher Class 1 - the single path data center Class 2 - the single path data center with redundant components Class 3 - the concurrently maintainable and operable data center Class 4 - the fault tolerant data center that contains two separate infrastructures with their own set of redundant components. Some of the key areas include a Telecommunications Entrance Room that contains the External Network Interface (ENI), wh American Wire Gauge (AWG) - Answer- Roughly represents the number of steps that were involved in the process of wire drawing. Smaller Numbers: Larger wires (fewer drawing steps are involved) Larger Numbers: Smaller wires (more drawing steps are involved) A gauge change of 3 numbers: Doubles or halves the conductors resistance and cross sectional area A gauge change of 6 numbers: Doubles or halves the conductors diameter
Document information
- Uploaded on
- November 18, 2023
- Number of pages
- 18
- Written in
- 2023/2024
- Type
- Other
- Person
- Unknown