LMRT-Radiography Essentials Questions and Answers 100% Solved
LMRT-Radiography Essentials Questions and Answers 100% Solved Which of the following changes in (KVP) will result in the greatest reduction of patient dose, when (MAS) is adjusted to compensate for the change? Increase kVp by 30% Which of the following (IR) system speeds will result in the lowest patient dose? Faster speed IR system What is the primary purpose of using gonad shields during radiography? Reduce the likelihood of genetic effects Contact & shadow are two types of gonad shield TRUE When should gonad shields be used? When the gonads are within 5cm of the radiation field The greatest cause of unnecessary radiation to patients that can be controlled by the limited operator are: repeat exposures The limited operator can reduce repeat exposures by: clearly instructing patients How does x-ray beam restriction minimize patient exposure It limits the radiation field to the area of interest What is the device that allows the limited operator to vary the size of the radiation field Collimator How does filtration reduce patient exposure Removes longer wavelength photons What is the National Council on Radiation Protection and Measurements (NCRP) recommendation for the amount of total filtration 2.5mm Al Equivalent What are the three principal methods used to protect limited operators from unnecessary radiation exposure? 1. Time 2. Distance 3. Shielding Which of the following is NOT a type of personnel radiation shielding? a. Apron b. Glove c. Thyroid shield d. Shadow******** CORRECT Personnel shielding must be worn on the rare occasion during which the limited operator may need to remain in the radiographic room during an exposure to assist the patient in maintaining the proper position. What is the source of the greatest radiation hazard under this circumstance? Scattered radiation from the patient What is the term from radiation that escapes from the x-ray tube housing? leakage radiation Why are limited operators prohibited from activities that result in direct exposure to the primary x-ray beam? They are considered occupationally exposed individuals Distance, as a method used to limit operator exposure, means that: the operator should maximize the distance from the source during an exposure. Shielding worn for personnel protection is designed to attenuate what source of exposure scatter radiation Which of the following is an acronym for a common type of personnel dosimeter TLD What is the recommended placement for a personnel dosimeter on the body of the limited operator The badge should be worn in the region of the collar on the anterior surface of the body and outside the lead apron if worn. What is the NCRP recommended annual effective dose limit for occupational exposure 5.0 rem (0.05 severt) What is the NCRP recommended monthly effective (or equivalent) dose limit to the fetus for a prego worker? 0.05 rem (0.0005 Sv) Radiation monitoring of personnel is required when what percentage of the annual occupational effective dose limit is likely to be received 10% What is the conventional (British system) radiation unit to express
Written for
- Institution
- LMRT-Radiography Essentials
- Course
- LMRT-Radiography Essentials
Document information
- Uploaded on
- November 15, 2023
- Number of pages
- 34
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
lmrt radiography essentials questions and answers
Also available in package deal