Spectrum FTT Weeks 1-3
Your hard hat is intended to protect you from which of the following? - -
Impact, penetration, and electric shock
-Which standard is imprinted on glasses or goggles that meet safety
requirements? - -ANSI Standard Z87.1-2010
-Which items of PPE do you need under normal working conditions (not
climbing)? - -Hard hat, safety glasses, safety vest, FVD, and gloves
-Which items of PPE would you need when working aloft on a ladder? - -
Hard hat, safety glasses, FVD, long-sleeved shirt, gloves, body belt,
positioning strap, and lineman's boots
-What happens to leather when it is dried too fast in excessive heat? - -The
leather curls and cracks
-How do you measure for proper "D" size on a padded body belt? - -Measure
hipbone to hipbone plus 2"
-Once at the working height, pass the positioning strap around the pole
and engage the single-sided end on the D-Ring with the mouth of the
snap hook _____________. - -Outward
-Always verify visually that the snap hook has engaged the
__________________. - -D-Ring
-You must document your monthly PPE inspection on the applicable
inspection form. - -True
-What type of safety vest is required? - -Class 3
-What is the minimum clearance of CATV cable from power at the pole? - -
40 inches
-What are the three indicators on the FVD? - -10-step bar graph, audible
tone, and power indicator LED
-To use the FVD, after the self-test process, continue to hold pressure on
the power switch and move the FVD: - -Toward the object you want to test
-To replace the battery of the FVD, use this tool to pry the cover off the
back of the device: - -Putty knife, coin or, small screwdriver
, -The FVD is only a voltage detector and is not intended to be a precision
measuring device. What other senses would you use as an additional
safety check? - -Sight, sound, and smell
-To determine if capacitive coupling is causing a hazardous voltage
indication, you should provide a temporary path to __________ for your
body to remove the voltage caused by the e-field of the power line. - -
Ground
-Indications of high current include - -Charring or melting of wires, and
smoke
-Metal buildings and mobile homes should normally indicate voltage is
present when tested. - -False
-How many times should you test a cyclic device, such as a traffic light
support strand? - -Three complete cycles
-When you ground yourself, the FVD should continue to indicate a
hazardous voltage. When the ground cord is released, the voltage will no
longer be detected. - -False
-Body Belt - -Worn low on the hips
-Eye Protection - -Wrap-around style provides side
protection
-Hard Hat - -Prevents injury from electrical hazards
-Safety Vest - -Class III with reflective striping
-Positioning Strap - -Double-locking keepers
-What is a breakaway clip used for? - -Haul cable or rope to the working
height
-9" Side Cutting Pliers - -Cuts RG-6 and RG-11 drop cables
-Bell-Hanger Wood Bit - -Equipped with a hole used to pull the cable
through
-Locking Terminator Tool - -Spring loaded action allows various brands to
be installed or removed
-7/16" Open-end Torque Wrench - -Properly tightens 'F' connector fittings
Your hard hat is intended to protect you from which of the following? - -
Impact, penetration, and electric shock
-Which standard is imprinted on glasses or goggles that meet safety
requirements? - -ANSI Standard Z87.1-2010
-Which items of PPE do you need under normal working conditions (not
climbing)? - -Hard hat, safety glasses, safety vest, FVD, and gloves
-Which items of PPE would you need when working aloft on a ladder? - -
Hard hat, safety glasses, FVD, long-sleeved shirt, gloves, body belt,
positioning strap, and lineman's boots
-What happens to leather when it is dried too fast in excessive heat? - -The
leather curls and cracks
-How do you measure for proper "D" size on a padded body belt? - -Measure
hipbone to hipbone plus 2"
-Once at the working height, pass the positioning strap around the pole
and engage the single-sided end on the D-Ring with the mouth of the
snap hook _____________. - -Outward
-Always verify visually that the snap hook has engaged the
__________________. - -D-Ring
-You must document your monthly PPE inspection on the applicable
inspection form. - -True
-What type of safety vest is required? - -Class 3
-What is the minimum clearance of CATV cable from power at the pole? - -
40 inches
-What are the three indicators on the FVD? - -10-step bar graph, audible
tone, and power indicator LED
-To use the FVD, after the self-test process, continue to hold pressure on
the power switch and move the FVD: - -Toward the object you want to test
-To replace the battery of the FVD, use this tool to pry the cover off the
back of the device: - -Putty knife, coin or, small screwdriver
, -The FVD is only a voltage detector and is not intended to be a precision
measuring device. What other senses would you use as an additional
safety check? - -Sight, sound, and smell
-To determine if capacitive coupling is causing a hazardous voltage
indication, you should provide a temporary path to __________ for your
body to remove the voltage caused by the e-field of the power line. - -
Ground
-Indications of high current include - -Charring or melting of wires, and
smoke
-Metal buildings and mobile homes should normally indicate voltage is
present when tested. - -False
-How many times should you test a cyclic device, such as a traffic light
support strand? - -Three complete cycles
-When you ground yourself, the FVD should continue to indicate a
hazardous voltage. When the ground cord is released, the voltage will no
longer be detected. - -False
-Body Belt - -Worn low on the hips
-Eye Protection - -Wrap-around style provides side
protection
-Hard Hat - -Prevents injury from electrical hazards
-Safety Vest - -Class III with reflective striping
-Positioning Strap - -Double-locking keepers
-What is a breakaway clip used for? - -Haul cable or rope to the working
height
-9" Side Cutting Pliers - -Cuts RG-6 and RG-11 drop cables
-Bell-Hanger Wood Bit - -Equipped with a hole used to pull the cable
through
-Locking Terminator Tool - -Spring loaded action allows various brands to
be installed or removed
-7/16" Open-end Torque Wrench - -Properly tightens 'F' connector fittings