Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

NAB NHA Exam- Physical, Environmental, and Atmosphere With Complete Solutions

Document preview thumbnail
Preview 2 out of 10 pages

NAB NHA Exam- Physical, Environmental, and Atmosphere With Complete Solutions

Content preview

NAB NHA Exam- Physical, Environmental, and
Atmosphere With Complete Solutions
the physical plant CORRECT ANSWERS all designed, constructed, equipped, and maintained to protect health and safety of residents, personnel, public
Life Safety Code (LSC) CORRECT ANSWERS Entire construction plan and materials meet LSC standards|||CMS requires unless have waiver or exception. CMS grants waivers on SNFs; states on NFs
(NFPA) CORRECT ANSWERS National Fire Protection Association ||established LSC
Purpose of LSC CORRECT ANSWERS to provide reasonable degree of safety from fire.
Waivers for Life Safety Code CORRECT ANSWERS If CMS finds a state fire and safety
code adequately protects residents and personnel thenLSC does not apply. OLder facilities may obtain a waiver if they are and have been in compliance with an older addition of LSC as specified by CMS.||Before a nursing home may be built it must present architectural plant to State Medicaid or designated agency that approves construction. All major renovations, such as additional beds, change in utilization of space, and so on must receive approval. The state provides guidelines on what must be
a approved. Upkeep and repairs do not require prior approaval.
Blue Prints CORRECT ANSWERS keep as-built plans available for surveyors who do LSC inspection as well as for repair persons who may need prints for big jobs.
LSC and other standards CORRECT ANSWERS Building and contact standards are set
by LSC, CMS, ANSI/ADAAG - (dependent on which the state chooses) and state and local codes. ||- for handicapped|-follow which on specific state requires (ANSI/ADAAG)
LSC and ANSI/ADAAG CORRECT ANSWERS LSC accepts both standards so they are
essentially all LSC standards. Administrator does not need to know EVERY standard, but must keep a copy of the "LSC Handbook" as reference. The architect who designs the facility must know and incorporate all LSC and other standards, but it is advisable for the NHA to check his building to ensure compliance.
LSC, ANSI/ADAAG, and CMS CORRECT ANSWERS **- building materials - fire-rate according to number of stories. 2 hour and 1 hour rating|**- sprinklers - new buildings have automatically activated by smoke/heat|- exits - no room more than 100 feet from exit. Lighted exit signs of specific size. |- walls extend continuously to roof deck of next floor. wall finish must meet flame-spread requirements ( have certificate of this)|- furnishings - curtains and carpet must meet fire rating|- rooms - CMS requirements - 4 residents to room MAX. 80 sq ft/resident (multi-resident room), 100 sq ft for single occupancy. requirement for rooms| CORRECT ANSWERS - direct access to corridor|- outside window (CMS) or door (LSC)|- privacy|- furnishing| separate bed, proper size and height| bedding appropriate to climate| individual closet space| bedside table| comfortable chair| enough overbid tables to meet needs of rsidents|- toilets (CMS, ANSI, ADA)|- bathing facilities (CMS)|- resident call system (CMS, LSC) 24/7 - back up system available|- temperature range (71-81 degree F) (three feet above floor), states set actual, A/C not required
Doors CORRECT ANSWERS All 44" or more in new construction (41.5 opening)|
outside doors open egress.|no locks on resident door except staff has key (LSC)||
Bathroom door 32" (ANSI/ADAAG)||Fire Doors with automatic hold-open devices required in corridors||(over bed tables not required for patient)
corridors CORRECT ANSWERS no dead-ends (LSC)||8 feet wide (CMS)
Floors CORRECT ANSWERS at or above ground level. (LSC) |Fire rating if carpeted. (LSC)|Non-slip bath/toilet (ANSI, LSC)|Asphalt tile best
Fire alarms CORRECT ANSWERS flashing and audible. |connect with local fire dept, if possible|must have NFPA 71 certification of fire alarm service|
smoke detectors CORRECT ANSWERS approved detectors requried
smoking CORRECT ANSWERS written regulations, enforced. |smoking ares with non-
combustible ashtrays, metal containers with self-closing lids.|Prohibited areas include resident rooms and beds, oxygen, flammable liquid storage.|proper signs posted.|
supervise non-responsible.
ANSI/ADAAG(Americans with Disabilties Act Accessibility Guidelines) CORRECT ANSWERS Make building available to and usable by physically handicapped, no mental
(blind, deaf, non-ambulatory, semi-ambulatory, uncoordinated). ADAAG = MAKE BUILDINGS AVAILABLE TO ADA'S. |State decides whether to apply ANSI or ADAAG standards to nursing homes
accessible route CORRECT ANSWERS no incline more than 10%
Wheelchair passage CORRECT ANSWERS 32" bathroom doors||36" elsewhere
parking CORRECT ANSWERS 13 FEET||cannot block sidewalk; alley for 2 cars.|The number of handicap parking places is determined from a grid issued by ANSI. It MUST BE NOTED THAT FOR EVERY EIGHT (8) HANDICAP PARKING SLOTS, ONE MUST BE VAN ACCESSIBLE.||If the facility only has one handicapped place, it must be van accessible.
ramps CORRECT ANSWERS maximum rise 30". Slope not more than 1:10

Document information

Uploaded on
October 21, 2023
Number of pages
10
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ElevatedExcellence
3.8
(178)
Sold
944
Followers
505
Items
18328
Last sold
3 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions