Toledo journeyman test| with complete solution
Toledo journeyman test| with complete solution Transformers are rated in - kva a conductor intended solely for grounding purposes shall be a bare conductor or be color coded - green with one or more yellow stripes the lighting unit load for a store is listed as _______ VA per sq. ft - 3 listed spa and hot tub packaged units shall be permitted to be cord and plug connected to facilitate the removal or disconnection of the unit for maintenance and repair, provided the maximum length of the cord does not exceed_________ ft and protected by a GFCI - 15 ft according to the NEC , no more than______ over current devices may be used in any one lighting and appliance panel board - no maximum Which of the following combinations of switches is used to control a light from 3 locations - To 3 way switches and 4 way switch In general branch circuit conductors supplying a single motor should have a capacity not less than______ % Of the motor full loaded circuit rating - 125% The primary of a transformer is the____ - Side connected to the source According to ohm's law if the resistance is 5 Ω in Ambridge is 20 amps what is the voltage - 100 According to code, a wire located in a partially protected area such as under a roof open porch would be located in? - A damp location The alternate source for legally required stand-by systems _______ be requires to have ground-fault protection of equipment - Shall not Residential direct bario residential branch circuits rated 120 votes or less with GFCI protection and a maximum over current protection of 20 amps shall have a minimum cover requirement of______ inches - 12 Service drop conductors show maintain how much clearance from the sides in bottoms of windows? - 3ft What is the maximum of #18 RFH-2 conductors that can be installed in 3/8 flex with external clamps? - 3 Guest rooms and guest suites that are provided with permanent provisions for cooking show have branch circuits in outlets install to meet the rules for______ units. - Dwelling Voltage is best described as? - Electrical pressure GFCI protection shall be provided for outlets not exceeding 240 bolts that supply______ installed in dwelling unit locations. - Boat hoists What is the size of the copper grounding conductor when the largest service entrance conductor is 1750 mcm copper? - 3/0 The resistance of a conductor is directly proportional to its? - Length All metal parts required to be bonded by this section shall be banded together using a solid copper bounding jumper, insulated covered or bear, not smaller than____? - 8 AWG According to code how many No. 14 THHN type conductors can be used in a run of 1/2 in. Rigid metal conduit? - 13 The code requires which of the following when replacing receptacles in existing installations? - Grounding type receptacles only if they can be properly grounded The lighting load for a store listed as ____ VA per sq ft - 3 In the case of a continuous load _______% of the nominal capacity of the circuit may be used? - 80% A grounding conductors is required for all runs of flexibal metal conduit over _____ft. in length - 6 All 15 and 20 amp receptacles installed in wet or damp locations are required to meet what standard? - Listed as weather resistant According to code, type______ cable and _______ cable may be used for direct burial. - USE & UF A 15 amp branch ci
Written for
- Institution
- Toledo journeyman
- Course
- Toledo journeyman
Document information
- Uploaded on
- October 1, 2023
- Number of pages
- 10
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
toledo journeyman test with complete solution
Also available in package deal