Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

Dell Client Advanced 2023/2024 Already Graded A

Document preview thumbnail
Preview 2 out of 8 pages

Dell Client Advanced 2023/2024 Already Graded A When the side cover of Precision Tower 7920 is not assembled, the system will still power on. False On Latitude 14 Rugged Extreme - 7414, which light is used to communicate error using Single LED ? not Power light We Import a Foreign configuration in a RAID Array, if: The array containing foreign configuration is in an Offline state Select statements that are true about Trusted Platform Module (TPM) not The Trusted Platform Module (TPM) is used to generate and store keys After completing a service incident on a Precision Tower 7920, technician attempts to run ePSA before re-assembling the side cover. However, system is not able to power on and displays LED error code of 4-7. What could be the issue? The intrusion switch is triggered and power is cut-off. Install the side cover to de-activate the intrusion switch. Before replacing any hardware, what is the recommended solution for the BSOD or system freezing? not Reseat the DIMMs If an Edge Gateway is Blinking green after the diagnostics, what does it indicate? ePSA Pass On a Precision Workstation, if a Hard drive status indicator flashes green, amber and then turns off; this indicates the drive is rebuilding False In general, an Anti-Static Mat is used to prevent Electrostatic damage True Onsite Services for Ruggedized Notebooks are limited to CRU parts and Service Assembly Parts. True How many thermal performance control modes are there in Alienware Area 51m to support different user scenarios? not 1.0 Overclocking is the process of making a computer or component in a computer operate faster than specified by the manufacturer by modifying the system parameters True In a PERC H730P controller, P stands for Performance True iDRAC with Lifecycle Controller can be used for: not OS Deployment A CAN (Controller Area Network) bus is a vehicle bus standard designed to allow micro controllers and devices to communicate with each other in applications without a host computer. True Under what scenarios can we clear the NVRAM by moving the PSWD jumper to the RTCRST pins? No POST No Video Where can the Field Service Manual containing Critical Callout, Disassembly and Reassembly instructions be found? PRM / Educate Dell iDRAC stands for: Integrated Dell Remote Access Controller What steps must be taken if there is a fan-related error message displayed at the Start up, but the system boots to the OS? not Check for Dust or debris on the Fans, clean them The following items are unaffected by the RTC reset: not Service Tag Which screwdriver is recommended for removing PHM (Processor Heat Sink module) used on a Precision Rack 7920? Torx #T30 USB Service Key is used for Windows OS installation and debranding (for OEM) in an Edge Gateway True Tobii eye-tracker module enables user to perform the following: not Interact intelligently with their computers Which keyboard key is used in an Edge Gateway 3000 series to start ePSA? not F11 What is not an example for IoT application? not Wearable gadgets The Edge Gateway 3000 series support the following power sources: not 3-pin DC -IN Select all the LED codes for Memory related issues in a Dell Edge Gateway 2,3 2,4 2,5 NIC Activity LED is off and Link indicator is green. This indicates NIC is connected to a valid network at its maximum port speed but data isn't being sent/received True BOSS stands for: not Boot Optimized Server Subsystem Which indicator shows whether power is present or a power fault has occurred in Precision Workstation systems? not AC PSU LED In a Precision Rack, one PSU is faulty and other one is fine. After hot plugging the new PSU, it starts to blink green and turns off. What do you think is the cause? PSU has Firmware/Voltage mismatch In a scenario where the System Board is replaced, remove the Processor Heatsink Module (PHM) together with the processor. There is no need to separate the PHM from the processor. True DPK stands for Digital Product Key The OEM Identity (ID) Module is a Utility used to replace the Dell Logo on the System Hardware like the Bezel False How many intrusion switches are there in Dell Precision Tower 7920? not 2 The BIOS can be accessed in a Dell System using which of the following keys: f2 The Dell Precision System board is shipped in Manufacturing mode and the User or Service Provider must select the manageability option upon first boot after replacement True ePSA stands for Enhanced Pre-boot System Assessment Which RAID mirrors the data between the two drives without parity? RAID 1 In an Alienware Notebook, which indicator is used to communicate error codes? Power button or battery LED In Alienware systems, errors are indicated via the tricolor Power Button LED. False After completing a service incident on a Precision Tower 7920, technician attempts to run ePSA before re-assembling the side cover. However, system is not able to power on and displays LED error code of 4-7. What could be the issue? The intrusion switch is triggered and power is cut-off. Install the side cover to de-activate the intrusion switch. Which RAID is defined as Striped set without Parity? RAID 0 The Easy Restore feature to restore Service tag, licenses, UEFI configuration is available in Rugged Latitude False Select all the guidelines that have to be followed when working in a Data Center Environment Only access racks that contain the equipment you are assigned to troubleshoot Communicate any problems to the Data Center staff No food or drinks allowed in the Data Center Check all that applies when troubleshooting PSU issue in a Dell Precision Rack PSU indicator will not illuminate if the power is not connected AC PSU indicator will be blinking green during a Firmware update AC PSU indicator blinks green five times at a rate of 4 Hz and turns off to indicate PSU mismatch In the latest Precision Rack, the iDRAC Enterprise license is available by default False


Document information

Uploaded on
September 23, 2023
Number of pages
8
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StellarScores
4.0
(517)
Sold
2007
Followers
867
Items
21197
Last sold
5 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.