Cof P-98 Practise Exam / 100 Questions And Verified Answers 2023/2024 / All Correct
COF P-98 PRACTISE EXAM / 100 QUESTIONS AND VERIFIED ANSWERS 2023/2024 / ALL CORRECT. COF P-98 Practice test 2023 1. The person supervising the Fuel-Oil transfer in the building from one floor to another must hold what type of certificate of fitness: P-98 Certificate of Fitness 2. In designing the fuel-Oil transfer system, such as diesel #2 oil from the lowest floor to the floor above the tank level, the following factors must be considered:: - Maximum inlet suction an flow-rate - Design of oil piping system and discharge pressure - Proper control strategy 3. _______________________ fires are caused by ordinary combustible materials (wood, paper, and cloth), for which the quenching-cooling effect of quantities of water is present: Class A 4. A stationary fuel-oil storage tank, and related piping, that is installed on the lowest floor of a building and that transfers fuel-oil through piping to another stationary fuel-oil storage tank, shall be under the GENERAL SUPERVISION of a:: P-98 Certificate of Fitness holder 5. The periodic inspection and testing of such tanks and piping shall be conducted under the _____________ of such P-98 Certificate of Fitness holder.: Personal supervision 6. Fuel-oil storage tanks and piping systems shall be inspected at least once ___________ for any evidence of leaks.: Weekly 7. Fuel-oil storage tanks shall have their float switches tested how often to ensure that they are in good working order?: Weekly 8. No oil burning equipment may be operated until a certificate of compliance has been issued by the:: NYC Department of Buildings 9. The P-98 C of F is required for all existing and new buildings where fuel is being transported from the lowest levels to tanks or equipment on upper floors as required by the: (2 answer): - NYC Fire Code - Mechanical Code 10. The oil storage tank provides the supply of oil for combustion in the ____________. It is kept inside a dike.: Oil burner 11. Which of the following circulates the oil throughout the oil storage tank system?: Suction pump 12. Dirt and sediment are present in the fuel-oil coming from the oil storage tank.: True 13. The ___________ removes most contaminants from the oil before the oil reaches the burner's strainer.: Oil filter 14. The suction line has to be at least ______ inches from the bottom of the tank for sediments not to be absorbed.: 6 15. Excessive vacuum readings indicate that there is an obstruction in the suction line (such as dirty oil strainer).: True
Document information
- Uploaded on
- September 12, 2023
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers