Hemodialysis Exam Review Questions and Answers With Complete Solution
Hemodialysis Exam Review Reuse dialyzer has been set up for a patient, the patient name is written on the dialyzer, but there is no processing stricker on the dialyzer. What should the Technician do? - Set up another dialyzer for the patient If during dialysis, the blood leak detector alarm sounds while the outflow dialysate hose is clear and Hemastix test reads negative the best course of action would be to: - Continue to monitor for actual blood leak Correct needle placement is important in the initiation of dialysis to minimize the risk of all the following EXECPT - Steal Syndrome Conductivity meters all function on ability to... - Pass an electrical current through the dialysate Toxic products that's accumulate in the body as a result of decrease kidney functions are urea - Creatinine, potassium and phosphorus Which of the following is NOT a possible sequela of hepatitis B - Pancreatitis Excess negative arterial pressure maybe due to all of the following EXCEPT: - Venous line separation What is the MOST complication during dialysis - Hypotension Which of the following is responsible for the ultimate disposal of medical waste - Facility from which it originated A patient with hard water syndrome: - nausea, vomiting and muscle weakness To communicate well through documentation entries in the medical record should be clear - Concise and Timely A patient immune system should normally provide protection from which of the following - Infection The venous pressure on the machine starts to rise, the needle is not infiltrated which one of the following could be a possible cause - The Venous needle is pointed in the wrong direction A key factor associated with the recent increase in incidence of TB is which of the following - Reduced immunity in the HIV positive Undissolved particle such as mud and sand are - Sediment Filter Which of the following may NOT be a common psychological reaction for patient beginning maintenance dialysis - Hostility Measure conductivity of finished dialysate with an external meter is - recommended by AAMI (Association for the Advancement of Medical Instrumentation) and manufacturers of dialysis machine When one begins Cardiopulmonary Resuscitation (CPR) - 30 compressions 2 vent The only mandated method for protecting healthcare workers from infection with bloodborne Pathogen - Isolation of documented disease carriers Air can get into extracorporeal circuit because - Because of the loose connection, through needles, from cracked connectors or from vented fluid containers Which of the following basic formula calculate the TMP required for desired fluid remove - Total fluid divide by Hr over Kuf dialyzer For which of the Purpose in mannitol used - To support blood pressure osmotically A system of water treatment that removes chloramines - Activate Carbon All of the following factors should be considered when choosing an appropriate dialyzer EXCEPT - Dialysate composition
Document information
- Uploaded on
- August 30, 2023
- Number of pages
- 5
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers