Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 70 pages
Exam (elaborations)

Home Inspector National Exam Questions and Answers Verified 2023/2024 (GRADED)

Document preview thumbnail
Preview 4 out of 70 pages

There shall be a wall switch at each floor to control stairway lighting where the stairway has _____ or more risers - 6 Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at least _____ inches in diameter - 1.5 inches Doors between the garage and residence shall be equipped with a - Self-closing door The _____ shall not be considered as an effective ground-fault current path - Earth For natural ventilation for habitable rooms, the min openable area to the outdoors shall be _____ percent of the floor area being ventilated - 4% Fuel gas appliance connectors shall not exceed an overall length of _____ feet - 6 ft. What size are fuel-gas-fired domestic clothes dryer ducts - 4 inches The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons. - 660 gals. The minimum bet area of ventilation openings shall not be less than _____ square foot for each _____ square feet of under-floor space - 1 sqft. for each 150 sqft Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of _____ inches into concrete or grouted cells of concrete masonry units - 1/2 in. , 7 in. Outdoorandreturnairforaforced-airheatingandcoolingsystemshallnotbetakenfrom- Address numbers shall be a minimum of _____ inches high with a minimum stroke width of _____ inch. - 4 inches , 1/2 inch Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and portions of basements containing these spaces shall have a ceiling height of not less than _______ feet. - 7 feet A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. - 5 feet Open web truss or I-Joist floor assemblies require a ____-inch gypsum wallboard membrane, ____-inch wood structural panel membrane, or the equivalent on the underside. - 1/2 And 5/8 Flanges and lips of load-bearing cold-formed steel floor framing members shall not be cut or ____. - Notched Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point where they pass through the roof. - 2 feet Foundations for masonry chimneys shall be constructed of concrete or solid masonry at least _____ inches thick - 12 inches Supports and foundations for the outdoor unit of a heat pump shall be raised at least ___ inches above the ground. - 3 inches Attic ventilation openings shall have a least dimension of _________ inch minimum to _________ inch maximum openings. - 1/16 And 1/4 All wood beams, joists, studs and other combustible material shall have a clearance of not lessthaninchesfromthefrontfacesandsidesofmasonryfireplaces.-2inches Stairways shall not be less than ____ inches in clear width at all points above the permitted handrail height and below the required headroom height. - 36 inches An automatic fire sprinkler system is not required when _____ or _____ are made to existing townhouses that do not have a sprinkler system - Additions and or Alterations Chimney shall extend at least _____ feet higher than any portion of a building within ____ feet. - 2 feet, 10 feet Window wells serving emergency escape and rescue openings shall be designed for proper ____. - Drainage Braces wall panels shall be constructed with intermittent bracing method s, or the continuous sheathing methods. Mixing of bracing methods shall be ______. - Permitted Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed. - Listed wireless (All alarms must sound upon activation of one alarm). Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed. - Listed wireless (All alarms must sound upon activation of one alarm). A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purposes of _____ or ______. - Repairs or Maintenance ANy portion of a masonry chimney located in the interior of a building or within an exterior wall shall have a minimum air space clearance to combustibles of _____ inches. - 2 inches TheprovisionsofSectionR505SteelFloorFramingshallcontroltheconstructionofcold- A pane of glass in a window requires safety glazing if the pane is greater than ____ square feet with a bottom edge less than ____ inches above the floor and top edge greater than ____ inches above the floor. - 9 sqft., 18 inches, 36 inches The connection between a deck ledger and a 2 inch nominal lumber band joist shall be constructed with _____ inch lag screws or bolts with washers - 1/2 inch At the intersection of asphalt shingles with a vertical sidewall, flashing shall be a minimum of _____ inches in height and ____ inches in width. - 4 inches, 4 inches The markings for identification of disconnecting means shall have the durability to withstand the _____ involved. - environment A _____ shall be provided at the base of each waste or soil stack - Cleanout All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to the grounding electrodes shall be __________________. - Accessible A flight of stairs shall not have a vertical rise larger than ____ feet between floor levels or landings. - 12 feet Sauna heaters shall be equipped with a thermostat that will limit room temperature to a maximum of ______ . - 194 *F Protection of wood and wood based products from ___ shall be provided by the use of naturally durable wood or wood that is preservative treated. - Decay In plumbing systems, supports for 1 inch copper or copper alloy tubing run horizontal shall not be spaced more than ______ feet apart. - 6 feet Onstairways,themaximumriserheightshallbeinches-73/4inches Where a masonry fireplace opening is less than 6 square feet, hearth extensions shall extend at least _____ inches in front of and at least _____ inches beyond each side of the fireplace opening. - 16 inches , 8 inches Enclosed accessible space under stairs shall have walls, under-stair surface and any soffits protected on the enclosed side with ______ inch gypsum board. - 1/2 inch There shall be at least ______ inches clearance in front of the water closet, bidet or lavatory to any wall, fixture or door. - 21 inches Type I handrail with a circular cross section shall have an outside diameter of at least _____ inches and not greater than _____ inches - 1 1/4 inches , 2 inches Switches shall not be more than ________ feet ________ inches above the floor or working platform when the switch is in its highest position. - 6 ft. 7 in. Wood studs in nonbearing partitions may be notched to a depth not exceeding ________ percent of a single stud width. - 40% The landing on the exterior side of required egress door is permitted to be a maximum of _____ inches below the top of the threshold provided the door does not swing over the landing. - 7 3/4 inches The provisions for structural insulated panel walls are limited to buildings not greater than ______ stories in height with each wall not greater than _____ feet high. - Two stories, 10 feet Mechanical appliances having an ignition source shall be elevated such that the source of ignition is not less than _____ inches above the floor in garages. - 18 inches In no case shall the point of attachment for service-drop conductors be less than______ feet abovefinishedgrade.-Finishedgrade-10feet Unused openings in cabinets and panelboards shall be effectively _____________ to afford protection equivalent to that of the wall of the cabinet. - Closed A minimum of _______ branch circuit shall be provided to supply the bathroom receptacle outlet(s). Such circuits shall have no other outlets. - One 20- amp At least one receptacle outlet in bathrooms is required to be within _______ inches of each lavatory basin. - 36 inches Other habitable rooms shall have a floor area of not less than ___ square feet. - 70 sq. ft. When joists, trusses or rafters are spaced more than 16 inches on center and the bearing studs below are spaced 24 inches on center, such members shall bear within ____ inches of the studs beneath. - 5 inches Mechanical appliances suspended from the floor shall have a clearance of no less than _____ inches from the ground. - 6 inches Hollow masonry piers shall be capped with ____ inches of solid masonry or concrete or a masonry cap block. - 4 inches Grout shall not be pumped through ____ pipes. - Aluminum An application for a permit of any proposed work shall be deemed to have been abandoned ____ days after the date of filing. - 180 days Roof drip edge shall be mechanically fastened to the roof deck at a maximum of ____ inches on center with minimum end laps of ____ inches. - 12 inches, 2 inches Afinishedorunfinishedarea,notconsideredastory,wheretheoccupiablespaceis Trenching installed parallel to footings shall not extend below the _____-degree bearing plane of the bottom edge of a wall or footing. - 45* Domestic clothes dryer transition ducts shall be metal and limited to a single length not to exceed _____ feet. - 8 feet When doing an air test on DWV systems during rough in plumbing, the portion under test shall be maintained at ______ psi for _____ minutes. - 5 psi. , 15 minutes Where a space for a _____________________ _____________________ is provided, an exhaust duct system shall be installed. - Clothes dryer Combustible material within ___ inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such opening. - 12 inches Masonry chimney walls or chimney flue linings shall not change in size or shape within _____ inches above or below where the chimney passes through floor, ceiling or roof components. - 6 inches The required egress door for each dwelling shall be side-hinged, and shall provide a minimum clear width of ___ inches. - 32 inches The drainage fixture unit (d.f.u.) value of a dishwasher is ______ . - 2 In Seismic Design Categories D0, D1 and D2, ______ stone masonry walls shall not be used - Rubble In cold formed steel framing, floor cantilevers for the top floor of a two or three story building or the first floor of a one story building shall not exceed ______ inches. - 24 inches IntwostorybuildinglocatedinseismicdesigncategoryD2,allbracedwallpanelsshallbe Basements, habitable attics and every sleeping room shall have at least one operable ____ ____ and ____ ____. - Emergency escape, and Rescue opening Overhead service conductors shall have a vertical clearance of not less than _____ feet above the roof surface. - 8 feet The minimum thickness of masonry fireplace hearths shall be _____ inches. - 4 inches Shower compartments shall have at least _____________________ square inches of interior crosssectional area. - 900 sq. in. Exterior masonry chimneys that pass through a soffit or cornice shall have a minimum air space clearance of _____ inch. - 1 inch Where emergency escape and rescue openings are provided they shall have a sill height of not more than ____ inches above the floor. - 44 inches


Document information

Uploaded on
August 25, 2023
Number of pages
70
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUDYROOM2026
3.5
(64)
Sold
412
Followers
212
Items
3879
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.