• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 11 pages
Exam (elaborations)

HVAC EPA 608 Certification Study Guide With Complete Solution

Document preview thumbnail
Preview 2 out of 11 pages

Are there drop-in replacements for R-12 systems? Why or why not? - Answer No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. What type of oil is used in R-134a and what oils will it mix with? - Answer Ester based oils and they do not mix with other oils What type of lubricant is used with HCFCs? - Answer Alkylbenzene lubricant What is difference b/w ternary blend a azeotropic blend? - Answer Ternary blends are three-part mixtures whereas azeotropic blends are blends of two or more compounds that act like a single compound. What is the trait of a hygroscopic lubricant? - Answer It absorbs (takes on) moisture What is temperature glide and what type of blend won't have it? - Answer Temp. blend is the difference between the dew point and the bubble point Dew Point - Answer Occurs when saturation temp in evaporator causes refrigerant to change from liquid to vapor Bubble Point - Answer Occurs when saturation temp in condenser changes refrigerant from vapor to liquid Will the gases in a ternary blend leak at the same rate? Why or why not? - Answer No because different refrigerants in blend have different vapor pressures, causing them to leak at uneven rates Refrigeration Process - Answer transfer of heat from one place to another Evaporator - Answer Absorbs heat into system from space to be cooled. Absorption of heat causes refrigerant to boil. Upon leaving, refrigerant changed to low pressure, low temperature vapor Compressor - Answer Takes low pressure, low temp vapor and changes it to a high-temp, high-pressure, superheated vapor and delivers it to the condenser Condenser - Answer Rejects heat from system and changes refrigerant from high-temp, high-pressure vapor into high-pressure, high-temp liquid Metering Device - Answer reduces pressure of refrigerant and changes the high-pressure, high-temp liquid into low pressure, low temp liquid. Compound Gauge - Answer Typically blue and measures low pressure (psig) and vacuum (inHg). High Pressure Gauge - Answer Red and measures high side (discharge) pressure. 0 to 500 psi What does a compressor compress? - Answer Vapor Why will refrigerant migrate to the crankcase in a compressor? - Answer Because of the vapor pressure difference between refrigerant and oil What color is the high pressure gauge? - Answer Red What color is the low pressure gauge? - Answer Blue What needs to happen if oil has been contaminated by burnout? - Answer Triple evacuate system, install permanent filter-drier, conduct deep vacuum before recharging What are three Rs of refrigeration? - Answer Recover, recycle, reclaim Recover - Answer to remove any refrigerant in any condition from system and store in external container without necessarily testing or processing in any way Recycle - Answer To clean refrigerant for immediate reuse by separating oil from refrigerant and removing moisture and acidity from refrigerant by use of products like filter driers Reclaim - Answer To process refrigerant to level of new product specifications as determines by chemical analysis What standards must refrigerant recovery equipment meet and what components must all Type I and Type II refrigerant systems have? - Answer EPA-approved equipment testing organization. Service aperture or process stub System-Dependent Devices - Answer Capture refrigerant with assistance of compressor and/or pressure of refrigerant in appliances from which refrigerant is being recovered Self-contained Devices - Answer Have independent means to draw refrigerant out of appliances What is nitrogen and a filter-drier used for after recovery? - Answer Use nitrogen to flush debris out of system after recovering refrigerant. Filter-drier should be installed to trap any debris that may cause damage to new compressor What must be done before starting an evacuation? - Answer Recover all refrigerant and attain the mandated vacuum level ASHRAE Standard 15-1994 - Answer Requires refrigerant sensor that will sound alarm and automatically start ventilation system in occupied equipment rooms where refrigerant from leak will concentrate


Document information

Uploaded on
August 23, 2023
Number of pages
11
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Grademasters
3.8
(46)
Sold
118
Followers
69
Items
2591
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.