C.S. Certification Exam, SPD Test, Sterile
Processing Study Material For Certification Exam
Which area is the first to accept responsibility for all supplies in the facility?
Correct Ans - Receiving

Which type of inventory distribution system requires the use of a pre-
determined inventory list? Correct Ans - Par Level

Just-in-time distribution systems are also known as Correct Ans -
Stockless Distribution

Ordering the optimum quantity of an item based on historical data is known
as Correct Ans - Economical Order Quantity

Which of the following are elements of a distribution system? Correct Ans
- patient charging, storage, and receiving

The most efficient distribution system is the Correct Ans - Total
exchange cart

The computerized locked supply system is a variation of the Correct Ans -
Par Level

Which distribution system requires the using department to be responsible
for maintaing inventory levels? Correct Ans - Demand

An ongoing inventory management system is known as a Correct Ans -
Perpetual Inventory System

In which distribution system are requisition filled and delivered as they are
received? Correct Ans - Demand

Inventory performance" (a rough indication of the effectiveness of the
inventory system) is evaluated by Correct Ans - percent of back order,
availability of critical items, and inventory turnover

,Which of the following is the MOST efficient and cost-effective method for
inventory control in the SPD ordering and data generation? Correct Ans -
Computerized Inventory Control System

The temperature in the sterile storage are should not exceed Correct Ans
- 75º F (24º C)

Shelving in the sterile storage area must be kept how far from the outside
walls? Correct Ans - 2 inches

The thickness of a sterility maintenance cover should be Correct Ans -
2 to 3 mils

The minimum number of air exchanges per hour in the sterile storage area
should be Correct Ans - 4

The relative humidity in the sterile storage area should not exceed Correct
Ans - 70%

Approximately how much space should be left between and item and the
inside edges of a peel pouch? Correct Ans - 1 inch

What is the maximum size and weight of a textile pack? Correct Ans -
12" x 12 x 20" 12 pounds

Which of the following packaging materials is acceptable for low-temperature
gas plasma and ozone sterilization Correct Ans - Tyvek

Basin sets should be prepared for sterilization with Correct Ans - an
absorbent material between each basin

Tamper-evident seal on rigid containers include Correct Ans - latches
and locks

What is the acceptable temperature range for the prep and packaging area?
Correct Ans - 68º F-73º F (20º-23º C)

The preparation and packaging area must have an air exchange rate of
Correct Ans - 10 per hr

,If a non-perforated tray is used for the sterilization of instrument sets, it must
be Correct Ans - Tilted on the sterilizer rack

The ideal humidity level in the preparation and packing area should be
Correct Ans - 50%

For sterilization, rigid containers must be placed Correct Ans - flat

Which of the following packaging materials is acceptable for steam
sterilization? Correct Ans - Non-woven wraps

Re-passivation of an instrument can be achieved by Correct Ans -
routine lubrication

What is the most difficult part of a hemostat to clean? Correct Ans -
box lock

Which of the following lubricants is recommended for use on surgical
instruments? Correct Ans - petroleum-based

What type of finish on a surgical instrument is used for laser procedures?
Correct Ans - ebonized

What is the final stage in manufacturing a surgical grade instrument?
Correct Ans - passivation

Which series of stainless steel is used is to manufacture malleable retractors?
Correct Ans - 300

The weakest part of the instrument is/are the Correct Ans - box locks

The layer on a surgical instrument created by the passivation process is called
Correct Ans - chromium oxide

A crack in a hand-held instrument would most likely be found in the
Correct Ans - box lock

, The appropriate sterilization cycle for an autoclave load containing a basin
set, a minor surgery set, and twelve towel packs is Correct Ans - 270 F
(132 C ) for 4 minutes, 30 psi and 20 minutes drying time

Cotton gauze cannot be used in which sterilization process? Correct Ans -
low temperature gas plasma

Which agencies are involved with the regulation and control of ethylene oxide
when it's used as a sterilant? Correct Ans - environmental protection
agency, food and drug administration, and centers for disease control and
prevention

Which of the following sterilization methods would be appropriate for
petrolatum gauze dressings? Correct Ans - dry heat

To eliminate the bioburden on metal surgical instrument within the SPD, the
MOST cost-efficient sterilization method is generally considered to be
Correct Ans - steam under pressure

There are two pressure gauges on a steam sterilizer. These gauges measure
the pressure in the Correct Ans - jacket and chamber

What is the maximum number of 100% EO cartridges permitted by OSHA to
be stored outside of a flammable goods cabinet? Correct Ans - 10

At the end of the sterilization cycle, the EO cartridges and the gloves used to
handle them should be Correct Ans - Aerated

Item to be sterilized in low-temperature gas plasma must be packaged in:
Correct Ans - Non-cellulose-based material

Generally, the EO biological test pack is placed in the Correct Ans -
Geometric center of the load

Which of the following devices are compatible with ozone sterilization?
Correct Ans - stainless steel instruments

Routine BI testing for steam sterilizers should be performed at least
Correct Ans - weekly

Document information

Uploaded on
July 8, 2023
Number of pages
37
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StudyHall
3.8
(230)
Sold
1340
Followers
825
Items
17111
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions