DaVita PCT Clinical Exam Diffusion - Correct answer-movement of dissolved PARTICLES across a semipermeable membrane from the side of HIGHER concentration TO side of LOWER concentration (across concentration gradient). at equilibrium, no net transport takes place & dialysis fluid needs to be exchanged. ultrafiltration - Correct answer-removes water from the blood by PUSHING it across the semipermeable membrane from the blood side within the dialyzer's hollow fibers to the dialysate side; pressure is added to the dialyzer to get the fluid out. TMP - Correct answer-transmembrane pressure; pressure in dialyzer. (+ TMP can show a clot). osmosis - Correct answer-movement of WATER across a semipermeable membrane from the side of LOWER solute concentration to the side with the HIGHER solute concentration, until equilibrium is reached. osmotic pressure gradients drive ultrafiltration. when drawing the post-BUN sample at the completion of the treatment... - Correct answer-1) turn off the UFR 2) decrease the dialysate flow rate to 300 ml/min or place the machine in bypass 3) reduce BFR to 50 ml/min 4) then wait 15 seconds 5) draw the BUN blood sample from arterial sample port (venous port can give falsely low readings). the post-BUN blood sample is related to the patient's _____ reading - Correct answer- Kt/V two possible causes in inaccurate Kt/V results include: - Correct answer-1) blood sample was drawn before correct time interval and access recirculation makes the Kt/V falsely high. 2) blood sample was drawn after correct time interval was completed, urea rebound makes the Kt/V falsely low. optimal dialysate temperature - Correct answer-36.6 maximum recirculation time after a machine has been set up prior to tx cannot exceed: - Correct answer-2 hours why do limit recirculation time? - Correct answer-limiting bacterial growth in machine what is the procedure for blood strikethrough of an external transducer protector? - Correct answer-finish pt tx, remove machine from floor and take to biomed, fill out an REM. if bleach and peracetic acid are mixed, a chemical reaction occurs, producing: - Correct answer-toxic gas what are the two requirements that must be met prior to initiating water system disinfection? - Correct answer-1) tx floor is free of pts. 2) no other processes are using dialysis water

Content preview

DaVita PCT Clinical Exam
Diffusion - Correct answer-movement of dissolved PARTICLES across a
semipermeable membrane from the side of HIGHER concentration TO side of LOWER
concentration (across concentration gradient).
at equilibrium, no net transport takes place & dialysis fluid needs to be exchanged.

ultrafiltration - Correct answer-removes water from the blood by PUSHING it across the
semipermeable membrane from the blood side within the dialyzer's hollow fibers to the
dialysate side; pressure is added to the dialyzer to get the fluid out.

TMP - Correct answer-transmembrane pressure; pressure in dialyzer. (+ TMP can show
a clot).

osmosis - Correct answer-movement of WATER across a semipermeable membrane
from the side of LOWER solute concentration to the side with the HIGHER solute
concentration, until equilibrium is reached.
osmotic pressure gradients drive ultrafiltration.

when drawing the post-BUN sample at the completion of the treatment... - Correct
answer-1) turn off the UFR
2) decrease the dialysate flow rate to 300 ml/min or place the machine in bypass
3) reduce BFR to 50 ml/min
4) then wait 15 seconds
5) draw the BUN blood sample from arterial sample port (venous port can give falsely
low readings).

the post-BUN blood sample is related to the patient's _____ reading - Correct answer-
Kt/V

two possible causes in inaccurate Kt/V results include: - Correct answer-1) blood
sample was drawn before correct time interval and access recirculation makes the Kt/V
falsely high.
2) blood sample was drawn after correct time interval was completed, urea rebound
makes the Kt/V falsely low.

optimal dialysate temperature - Correct answer-36.6

maximum recirculation time after a machine has been set up prior to tx cannot exceed: -
Correct answer-2 hours

why do limit recirculation time? - Correct answer-limiting bacterial growth in machine

Document information

Uploaded on
July 6, 2023
Number of pages
3
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$3.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
577
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions