• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 133 pages
Exam (elaborations)

FLORIDA HOME INSPECTOR EXAM|UPDATED&VERIFIED|GUARANTEED SUCCESS

Document preview thumbnail
Preview 4 out of 133 pages

Service entrace conductors run from the service drop to the service box or service panel. True or False? True The service size is determined by the amperage and the voltage ratings of the service. True Is the service drop overhead or underground? Overhead Are service laterals overhead or underground? Underground The drip loop is typically part of the service drop. True or False? False The wire size for the service drop must be the same as the wire size for the service entrance conductors. True or False? False How many wires would you typically find in a 240-volt service drop? 3 What would 4 wires mean? 3-phase electricity What would 2 wires usually mean? 120 volt service List 7 common problems with service drops. 1. Overhead wires too low. 2. Damaged or frayed wires. 3. Trees or vines interfering with wires. 4. Wires too close to doors or windows. 5. Wires not well-secured to the house. 6. Poor connection between service drop and service entrance. 7. Inadequate clearance from roofs. List clearances above ground, swimming pools, and roofs. above roadway--18 ft. above driveway--12 ft. above flat roof--8 to 10 ft. above sloped roof--18 inches away from water in swimming pool--22.5 ft 3 ft. above sloped roof with pitch 4 in 12 above walkway--10 ft. The service entrance conductors run from the _________ to the ___________. service drop to service box All service entrance conductors must be in conduit. True or False? False All service entrance conductors must be attached above roof level. True or False? False The drip loop should be as close to the roof as possible. True or False? False List 10 common problems with service entrance conductors. 1. No drip loop 2. No mast head 3. Mast head not weather tight. 4. Mast or conduit bent. 5. Mast or conduit rusted. 6. Mast rotted (if wood). 7. Mast conduit or cable not well secured. 8. Mast conduit or cable not weather tight. 9. Conduit or cable not well sealed at house/wall penetration. 10. Cable frayed, damaged, or covered by siding. List 4 common areas of water penetration into service entrances. 1. conduit joints 2. mast head 3. roof flashing 4. meter base 5. house entry List 2 functions of the drip loop. 1. Prevents water entry into the conduit or service entrance conductors. 2. Shows that the service drop wires are not straining the splices. Roughly 999 out of 1000 houses have _________ volts available. 240 Roughly 999 out of 1000 houses have __________ service entrance wires. 3 Load calculations are part of a home inspection. False Implications of an undersized service include: a. shock hazard b. fire hazard c. shock and fire hazard d. melting insulation e. nuisance tripping of the main fuses and breakers e. What is the largest single-phase service that you are likely to find in a home? 400 amps What size copper wire would you expect to find on the service entrance for: a. 60-amp service b. 100-amp service c. 200-amp service a. 6 gauge b. 4 gauge c. 2-0 gauge Which of the following is a reliable way to identify the service size? a. the size of the service drop wires b. the distribution panel rating c. the service box rating d. the service entrance conductor e. the service entrance conduit size d. Aluminum is an acceptable service entrance conductor material. True or False? True A fused 200-amp service has two 100-amp fuses in the service box. True or False? False If you can't read the size of the fuses in the service box, you should remove them to try to get a better look. True or False? False Which of the following is a safety issue: a. The main fuses have a lower rating than the service entrance wire. b. The main fuses have a higher rating than the service entrance wire. c. The service box has a higher rating than the service entrance wires. d. The service box has the same rating as the service entrance wires. e. The distribution panel has a larger rating than the service entrance wires. b


Document information

Uploaded on
July 1, 2023
Number of pages
133
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GUARANTEEDSUCCESS
4.3
(253)
Sold
691
Followers
314
Items
24876
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.