• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

NICET 2 (A+ Graded)

Document preview thumbnail
Preview 2 out of 7 pages

Where located above floor (within 2.1m or 7ft.) cables shall be securely fastened at intervals of? correct answers not more than 18 inches Which cable types can be installed in fireproof riser shafts? correct answers FPLP, FPLR, and FPL How many THHN conductors can fit in a 3/4 size Rigid PVC conduit? correct answers 17 This is the defined as the height from the continuous floor of a room to the continuous ceiling of a room or space? correct answers Ceiling height The visible annunciation of the location of operated initiating device shall not be? correct answers by the means used to deactivate alarm notification appliances. Subsequent trouble signals shall cause trouble notification appliances to activate as required by what? correct answers system input/ output matrix System equipment shall be maintained in accordance with what? correct answers Manufacturer's published instructions The detector sensitivity shall not be tested or measured using any device that administers? correct answers an unmeasured concentration of smoke or other aerosol into the detector or smoke alarm Sensitivity shall be checked within how long? correct answers 1 year after installation Where partitions extend to within 15% of the ceiling height, the spaces separated by the partitions shall be? correct answers considered separate rooms Spot-type heat detectors shall include? correct answers Response time index The first line of detectors shall be located at or within? correct answers 36 inches of the peak of the ceiling Smoke detectors shall be marked with? correct answers with their nominal production sensitivity and tolerance in in percent per foot obscuration Spot-type smoke detectors shall be permitted to be located on ceiling or on the bottom of beams for ceilings with beam depths of? correct answers less than 10% of the ceiling height. If any barrier, such as a door, curtain, or retractable partition is located in sleeping areas, sound pressure level shall be measured? correct answers with the barrier placed between the appliance and pillow


Document information

Uploaded on
June 28, 2023
Number of pages
7
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
807
Followers
438
Items
40070
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.