NFPA 921 Exam Questions With Complete Solution
NFPA 921 Exam Questions With Complete Solution NFPA 1033 Standard for Professional Qualifications for Fire Investigator - CORRECT ANSWER Facilitates safe, accurate investigations by specifying the job performance requirements (JPRs) necessary to perform as a fire investigator in both the private and public sectors. NFPA 921: Guide for Fire and Explosion Investigations - CORRECT ANSWER Guide for Fire and Explosion Investigations", is a peer reviewed document that is published by the National Fire Protection Association (NFPA). Its purpose is "to establish guidelines and recommendations for the safe and systematic investigation or analysis of fire and explosion incidents" (section 1.2.1). Familiarity with NFPA 921 is strongly recommended by National Association of Fire Investigators and the International Association of Arson Investigators (IAAI). NFPA 921 forms a large basis of the information which a professional fire investigator must know to pass the various Fire Investigator Certification (NAFI and IAAI) examinations. Spoliation - CORRECT ANSWER is the destruction or alteration of evidence through intention or ignorance. Qualification - CORRECT ANSWER The National Fire Protection Association (NFPA), through a document known as NFPA 1033, Standard for Professional Requirements for Fire Investigator, publishes minimum requirements for the knowledge skills and ability of a fire investigator. Principal among these is a 16-point list of areas in which a fire investigator is required to have education beyond high school level. These 16 topics are: Fire science Fire chemistry Thermodynamics Thermometry Fire dynamics Explosion dynamics Computer fire modeling Fire investigation Fire analysis Fire investigation methodology Fire investigation technology Hazardous materials Failure analysis and analytical tools Witnesses information and/or Electronic Data - CORRECT ANSWER The analysis of observations reported by persons who witnessed the fire or were aware of conditions present at the time of the fire as well as the analysis of electronic data such as security camera, footage, alarm system activation, or other such data recorded in and around the time of the fire event Fire Patterns - CORRECT ANSWER The analysis of effects and patterns left by the fire ARC Mapping - CORRECT ANSWER The analysis of the locations where electrical arcing has caused damage and the documentation of the involved electrical circuits Fire Dynamics - CORRECT ANSWER The analysis of the fire dynamics[i.e., the physics and chemistry of fire initiation and growth and the interaction between the fire and the buildings system Code - CORRECT ANSWER A standard that is an extensive compilation of provisions covering broad subject matter or that is suitable for adoption into law independently of other codes and standards. Standard - CORRECT ANSWER An NFPA standard, the main text of which contains only mandatory provisions using the word "shall" to indicate requirements and that is in a form generally suitable for mandatory reference by another standard or code or for adoption into law. Includes all NFPA standards, including codes, standards, recommended practices and guides. Absolute Temperature - CORRECT ANSWER A temperature measured in Kelvins or Rankines Accelerant - CORRECT ANSWER A fuel or oxidizer, often an ignitable liquid, intentionally used to initiate a fire or increase the rate of growth or spread of fire. Accident - CORRECT ANSWER An unplanned event that interrupts an activity and sometimes causes injury or damage or a chance occurrence arising from unknown causes; an unexpected happening due to carelessness, ignorance, and the like. Active Fire Protection System - CORRECT ANSWER A system that uses moving mechanical or electrical parts to achieve a fire protection goal Ambient - CORRECT ANSWER Someone's or something's surroundings, especially as they pertain to the local environment; for example, ambient air and ambient temperature. Ampacity - CORRECT ANSWER The maximum current, in amperes, that a conductor can carry continuously under the conditions of use without Exceeding its temperature rating. Ampere - CORRECT ANSWER The unit of electric current that is equivalent to a flow of one coulomb per second, one coulomb is defined as 6.24 x 10 18th power electrons Arc - CORRECT ANSWER High temperature luminous electric discharge across a gap or through a medium such as charred insulation. Arc Mapping - CORRECT ANSWER The systematic evaluation of the electrical circuit configuration, spatial relationship of the circuit components and Identification of electrical arc sites to assist in the identification of the area of origin and analysis of the fire spread Arc Site - CORRECT ANSWER That location on the conductor with localized damage that resulted from an electrical arc. Fire and Energy - CORRECT ANSWER Fire is a rapid oxidation process, which is an exothermic chemical reaction, resulting in the release of heat and light energy in varying intensities.
Written for
- Institution
- NFPA 921
- Course
- NFPA 921
Document information
- Uploaded on
- March 30, 2023
- Number of pages
- 18
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- nfpa 921
- nfpa 921 exam
-
nfpa 921 exam questions with complete solution
-
nfpa 1033 standard for professional qualifications for fire investigator
-
nfpa 921 guide for fire and explosion investigations
Also available in package deal