FMC test Complete And Graded A+ To Pass!!
When should alarm and pressure holding test be performed on dialysis machine Before each treatment In order to determine the adequacy of a dialysis treatment which of these laboratory values should be evaluated Blood urea nitrogen What is the purpose of maintaining a log of water quality checks To prove safe water has been documented When is the correct time to draw a post bun Before returning the patient's blood Which of these parameters on the hemodialysis machine must be verified pretreatment buy an external measuring device PH and connectivity The heater on the hemodialysis machine has a malfunction and as a result the temperature of the dialysis has risen above 105 Fahrenheit what complication is likely to occur Hemolysis The patient has completed their treatment the PCT SS the patient to the scale to be weighed suddenly the patient tells the PCT she does not feel well she complains of being dizzy what should the PCT do next Call the nurse to assist a patient The purpose of reverse osmosis device is To provide high-quality high quantity water It is important to monitor pump pressure on the reverse osmosis device to Determine changes that may affect product or waste water flow The water softner exchanges sodium ions for Calcium and magnesium ions When teaching a patient about prevention of hypotension during the treatment the nurse should include which of these instructions Always take prescribed medication at least 30 minutes prior to treatment Which of the following has the highest potassium content Bananas orange juice and salt The group of symptoms that include feelings of fainting and double vision irritated and hunger may be associated with what patient complication Hypoglycemia When caring for a patient who is Hepatitis B positive after disconnecting the bloodlines what must the technician do before documenting Remove gloves sanitize hands and put on a fresh pair of gloves According to FMC policy the safe level for total chlorine is Less than 0.10PPM The purpose of the carbon tanks in dialysis is to Remove chlorine and chloramine from feed water Join the setup all the dialysis machine A co-worker states that the PCT has contaminated the circuit which of the following would be most likely source of contamination The Bloodlines are in the prime bucket with open end caps The function of the blending valve in the water treatment system is to Mix hot and cold water to achieve an acceptable temperature Available weight gain is described as the Pretreatment weight minus dry weight Doing safety checks the technician notes the following which one requires intervention Access and the patients face are covered Use of a diasafe filters allows the production of Ultrapure dialysate Which alarm will not stop the blood pump Blood pressure alarm Dialysate used for in center hemodialysis is Non sterile and biocompatible The patient comes to dialysis with complaints of cramping since last treat. The clinician should. Look at previous dialysis flow sheets to evaluate adjustment of Target weight Which component of the water treatment system must never be bypassed carbon tanks The venous pressure on the dialysis machine starts to rise but the Venus needle is not infiltrated the rise is most likely due 2 The acccess clotting When should the water be checked for total chlorine during routine operations of the outpatient facility Before the first treatment is started before each shift begins or not to exceed four hours Normal saline is used to rinse and prime the tubing of the extracorporeal circuit to remove Sterilant and air A patient begins to experience shortness of breath chest pain and sudden hypertension the blood is bright red and translucent the complication most likely occurring is hemolysis During dialysis a patient has a cardiac arrest which action should be completed on the dialysis machine before the machine is used by another patient Technical must perform a functional test on the machine To properly collect a post bun sample it is necessary to turn off ultrafiltration rate Water for dialysis is treated to Protect patients from contaminants Which of the following complications is most likely caused by a kink in the bloodline Hemolysis Prior to testing the RO machine must run a minimum of 15 minutes
Document information
- Uploaded on
- October 17, 2022
- Number of pages
- 6
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers