• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 1 out of 4 pages
Exam (elaborations)

EPA Type 1 Practice test 2022

Document preview thumbnail
Preview 1 out of 4 pages

Technicians who perform sealed system service on small appliances must have; - ANSWER Type I or Universal certification. A small appliance is defined by EPA as; - ANSWER Appliances manufactured, charged, and hermetically sealed in a factory with 5 Lbs or less of refrigerant Type I Certification is required for; - ANSWER persons handling refrigerant during maintenance, service, or repair of small appliances If regulations change after the technician becomes certified; - ANSWER The technician is responsibility for complying with any future changes in the regulations. Recovery equipment manufactured after November 15, 1993 must be; - ANSWER capable of recovering 90% of the refrigerant in the compressor os operating; 80% of refrigerant if its not or 4 inches of vaccum Which of the following is true of small appliances refrigerant leaks; - ANSWER EPA does not require repair, but leaks should be repaired whenever possible. Recovery equipment manufactured after November 15, 1993 must be capable of recovering; - ANSWER 90% refrigerant or or achieving 4 inches of vacuum. Recovering multiple types of refrigerants in the same cylinder; - ANSWER will make the reclaimed refrigerants non reclaimable and a charge for disposal may be levied. Self-contained or active recovery equipment; - ANSWER Has its own means of recovery. System-dependant or passive recovery equipment; - ANSWER Captures refrigerant into a non-pressurized container with assistance of the appliance compressor. What is defined as a non-condensible? - ANSWER Air When using a system-dependent recovery system on an appliance that has an operating compressor, the technician should; - ANSWER Run the compressor and recover from the high side of the system. When using a system-dependent recovery system on an appliance that has a non-operating compressor, the technician should; - ANSWER Place access fitting on both the low and high side of the system. System-dependant devices may only be used on appliances containing; - ANSWER 15 pounds of refrigerant or less. Small appliances are equipped with a straight piece of tubing (process stub) used to; - ANSWER install a piercing type access valve fitting. If a strong odor is detected while performing the recovery process, - ANSWER A compressor burnout has likely occurred. After the refrigerant has been recovered, which of the following can be used to flush the system? - ANSWER Nitrogen When filling a charging cylinder with a regulated refrigerant; - ANSWER The refrigerant vapor that is vented off the top of the cylinder must be recovered. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; - ANSWER Recovery is not required. Applying heat with a heat gun to the compressor; - ANSWER can help vaporize any trapped liquid refrigerant during recovery. Refrigerators in the 1950's and earlier may have used what refrigerants (recovery is not required)? - ANSWER Methyl Formate, Methyl Chloride, or Sulfur Dioxide. Small appliances in recreational vehicles may use refrigerants such as Ammonia, Hydrogen, or water, and therefore; - ANSWER The refrigerant should not be recovered. Recovery equipment manufactured before November 15, 1993 must be capable of recovering. - ANSWER 80 percent of the refrigerant or achieving 4 inches of vacuum. When pressurizing a system with nitrogen you should; - ANSWER charge through a pressure regulator;place a relief valve in the downstream line from the pressure regulator. After recovering refrigerant, the Nitrogen used to flush the system may be: - ANSWER legally vented. The sale of CFCs and HCFC's are - ANSWER restricted to certified technicians ARI 740 sets - ANSWER recovery requirements All equipment must be equipped with - ANSWER low loss fittings Low loss fittings should be able to - ANSWER close manually or automatically when hoses are disconnected to minimize refidgerant loss Before beginning a refrigerant recovery procedure, it is necessary - ANSWER to know the type of refrigerant that is in the system. self contained (active) recovery equipment stores itself in a - ANSWER pressurized recovery tank Before opening a self contained recovery machine make sure the - ANSWER inlet valve is open, and tank does not contain excessive air (non condensables) The only way to read refrigerant pressure correctly is at - ANSWER a stable known temperature Air in refrigeration systems will cause - ANSWER higher discharge pressures When purging non-condensables abide by - ANSWER operating instruction supplied by equipment manfactuer All refrigerant recovery equipment should be check for what on a daily basis - ANSWER oil level and leaks A system depended has a - ANSWER special charcoal activated plastic "bag" containers System dependent equipment captures refrigerant with the assistance of - ANSWER an applicant compressor, external heat source, or vacuum pump A standard vacuum pump can only be used in combination with a - ANSWER non-pressurized container In order to release trapped refrigerant from the compressor oil - ANSWER heat and tap the compressor several times and/ or use a vacuum pump Because appliances with non-operating compressors can not always achieve desired evacuation rates utilizing system dependent equipment - ANSWER The EPA requires at least one self contained recovery device available at the shop The exception to the EPA required rule of a self contained device available is technicians - ANSWER working on small appliances only System dependent devices may only be used on appliances - ANSWER containing 15 lbs. of refrigerant or less. When installing an access fitting onto a sealed system, - ANSWER the fitting should be leak tested before proceeding with recovery. It is generally recommended that _____ ____ type valves be used on only copper or aluminum tubing material, these fitting tend to leak over time and should not be left on a permanent service fixture. - ANSWER Solder-less piercing After installing a access fitting you the system pressure to be 0 PSIG - ANSWER do not begin recovery process. Operating a defrost heater on a domestic frost free refrigerator will help to - ANSWER vaporize any trapped liquid refrigerant and will speed the recovery process. When recovering refrigerant from a system that experienced a compressor burn-out, - ANSWER watch for signs of contamination in the oil. Small appliances may use such refrigerants as __,___,___ and therefore should not be recovered with current using current recovery equipment. - ANSWER Ammonia, Hydrogen, Water


Document information

Uploaded on
September 21, 2022
Number of pages
4
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$10.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
millyphilip
3.7
(562)
Sold
3010
Followers
1964
Items
47643
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.