KENTUCKY UST CERTIFICATION EXAM
REVIEW WITH TESTED QUESTIONS AND
CORRECT SOLUTIONS

◉ As an alternative lifting method, should a cable or chain be
wrapped around the tank? Answer: No, Never!


◉ When you are lifting a tank, using the lifting lugs, which of these
procedures should be followed? Answer: attach a triangle cable
through the lugs with no more than a 30 degree angle from the
center line.


◉ After you unload a new tank on a clean level surface at the job site
what else should you do prior to inspection and pre-testing?
Answer: Chock the tank to prevent it from Rolling


◉ which of the following items should be physically checked for
damage or imperfections at the job site? Answer: Piping (steel and
fiberglass)
Fittings, Vents, Fillboxes, anodes, ECT..
The tanks themselves
(ALL OF THE ABOVE)!


◉ STI-P3 tanks are delivered with shipping plugs in tank openings.
What should be done to these plugs prior to testing? Answer:

,remove the plugs and replace them with a standard threaded plug
that is properly doped


◉ should dielectric bushings be installed in all openings of an STI-P3
tank? Answer: yes on all openings


◉ what is the maximum air pressure to which a steel tank should be
subjected in a pre-installation test? Answer: 5 pounds


◉ for fiberglass reinforced plastic (FRP) tanks up to 12 feet in
diameter what is an acceptable air pressure to which the tanks may
be subjected in a pre-installation test? Answer: 3 pounds


◉ for FRP tanks over 12 feet in diameter what is the maximum air
pressure to which the tanks should be subjected in a pre-installation
test? Answer: 3 pounds


◉ when you are conducting an air test on a tank the type of gauge
that should be used is? Answer: a pressure gauge with a maximum
limit of 10 to 15 PSIG


◉ the proper procedure for conducting a pre-installation air test of a
steel tank is to? Answer: apply 3 to 5 pounds of pressure and soap all
surfaces and weld seams visible through the coating while
inspecting for bubbles.

,◉ what is the proper procedure for conducting a pre-installation air
test of an FRP tank Under 12 feet in diameter is to.... Answer: apply 3
pounds of air pressure and soap all surfaces while inspecting for any
sign of a leak either audible or visible in the form of bubbles on the
surface


◉ a double-walled steel tank build in accordance with UL standard
58 is? Answer: requires air testing of the interstitial space prior to
installation


◉ the proper procedure for conducting a pre-installation air test of a
double-walled tank is to? Answer: pressurize the inner tank monitor
the pressure for one hour and then pressurize the space between
the inner and outer tanks with the air from the inner tank


◉ when shipped a steel tank is covered with a coating that is an
important part of the tanks Corrosion Prevention system. "holidays"
which show up in the coating at the installation site should? Answer:
should be touched up with a compatible coating after proper surface
preparation


◉ touch up of holidays in a steel tank coatings at the installation site
should be done....... Answer: according to the manufacturer's
instructions

,◉ dielectric bushings are usually made of what? Answer: non-
metallic material


◉ factors to consider in determining the size shape and depth of a
tank excavation include what? Answer: *the tank manufacturers
recommendations
*the requirements for compacting bedding and backfill as well as
stability of the soil
*the depth of cover


AKA all of the above


◉ in the absence of local requirements the recommended minimum
distance between a tank excavation and adjacent structures or
property lines is how many feet? Answer: 5 feet


◉ reinforcement of a steel underground tank may be required by the
tank manufacturer if Answer: the burial depth is greater than the
tank diameter


◉ according to FRP tank manufacturers specifications the burial
depth for an FRP tank should not exceed how many feet? Answer: 7
feet

Document information

Uploaded on
November 28, 2026
Number of pages
35
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4
Followers
0
Items
9515
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions