• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 24 pages
Exam (elaborations)

CBSPD Exam Practice Question Set - Practice-Ready Answer Guide

Document preview thumbnail
Preview 3 out of 24 pages

CBSPD Exam Practice Question Set - Practice-Ready Answer Guide Superheating can occur - answer - If the steam pressure is too low for the set temperature Wet packs - answer - Wet steam can cause 68-73 degrees - answer - AAMI recommends that the temperature in the sterilization area be: 30%-60% - answer - AAMI recommends that the humidity is the sterilization area be 10 - answer - The recommended ventilation in the sterilization are is—— air exchanges per hour under positive pressure 75-85/10/negative - answer - AAMI recommends that the temperature in the sterilizer access area be —- with — air exchanges per hour and under — pressure Decon, the sterilizer access area, EVS closet - answer - The only 3 areas in SPD that should have negative pressure are: sterility - answer - — is the absence of all forms of microbial life, including bacterial spores One in a million; 10(-6) - answer - An item is considered sterile if there is less than —— chance that a viable microorganism has survived the sterilization process. This is reflected numerically as —- Sterility Assurance Level - answer - SAL= Steam - answer - — kills microorganisms by denature great the protein steam sterilization - answer - — is the most common form of sterilization for items that are heat- and moisture-tolerant saturated steam under pressure, time, and temperature - answer - Three parameters of steam sterilization cycles are Dynamic-air-removal cycles - answer - — are used in prevacuum sterilized and in steam-flush pressure-pulse (SFPP) Prevacuum sterilizers - answer - — remove air by drawing series of vacuums with an injection of steam between each vacuum pull. Bowie-Dick test - answer - Performed daily to detect air leaks or inadequate air removal from prevacuum sterilzers Gravity-displacement cycles - answer - Incoming steam displaces residual air through the drain at the bottom of the sterilizer chamber: Gravity-displacement - answer - Because there is no mechanical air removal in a —, a Bowie-Dick test is not required for — or sterilizers Boiler - answer - In most healthcare facilities, steam is generated inside of a: 60-80psig - answer - The required pressure of steam as it enters the jacket is usually: 28-30 lbs of pressure - answer - For a sterilizer operating at 270 degrees, the sterilizer gauge will show: An insulating jacket - answer - Provides heat inside the chamber to prevent condensation from forming on the chamber walls: Heat-sensing thermometer - answer - The sterilizers - - - is locates in the drain line The drain line - answer - The coldest part of sterilizer is Bottom rack, drain line - answer - All PCDs should be placed on the —, directly over the — On the bottom rack above the drain line - answer - The Bowie-Dick test pack is placed Conditioning, sterilization/exposure/"holding, Exhaust, Drying - answer - The phases of steam sterilization cycles are: Conditioning phase - answer - During this phase, air is removed from the sterilization chamber and steam is injected Sterilization/exposure/holding - answer - In this phase, the exposure temperature is maintained for the prescribed amount of time. Exhausted, Exhaust phase - answer - After the exposure phase, steam is — from the sterilizer through the chamber drain line is this phase: Drying phase - answer - After the steam has been exhausted, the sterilizer goes into the - of the cycle which typically lasts about 30 minutes • 4 minutes @ 270 and 28-30 psi • 3 minutes @ 275 and 38-30 psi - answer - The cycle for wrapped items using Dynamic-air-removal steam is: • 30 minutes @ 350 and 15 psi • 15-20 minutes @ 270 and 27 psi • 10 minutes @ 275 and 30 psi - answer - The cycle for wrapped items using Gravity-displacement steam: BI PCD - answer - To verify that the cycle met the requirements for sterilization, a — should be included in the load (whether or not the load contains implantable devices) Immediate-Use steam sterilization (IUSS) - answer - —- is usually perfor


Document information

Uploaded on
October 31, 2026
Number of pages
24
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
9
Followers
0
Items
4200
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.