Preview 4 out of 103 pages
Exam (elaborations)

Certified Pulmonary Function Technologist (CPFT) Exam 2026: Professional Certification Practice Examination — Pulmonary Function Equipment, Calibration, Diagnostic Procedures, Spirometry, Lung Volumes, Diffusion Testing & Data Interpretation — 190 Mul

Document preview thumbnail
Preview 4 out of 103 pages

Certified Pulmonary Function Technologist (CPFT) Exam 2026: Professional Certification Practice Examination — Pulmonary Function Equipment, Calibration, Diagnostic Procedures, Spirometry, Lung Volumes, Diffusion Testing & Data Interpretation — 190 Multiple-Choice Questions with Answers & Detailed Rationales

Content preview

Certified Pulmonary Function Technologist (CPFT) Exam 2026:
Professional Certification Practice Examination — Pulmonary
Function Equipment, Calibration, Diagnostic Procedures,
Spirometry, Lung Volumes, Diffusion Testing & Data Interpretation
— 190 Multiple-Choice Questions with Answers & Detailed
Rationales




Question 1



A pulmonary function technologist is preparing a spirometer for daily testing. The device
uses a pneumotachometer. Which calibration procedure is most appropriate before patient
testing begins?



A. Calibrate with a 3-L syringe at three different flow rates

B. Perform a linearity check using a 1-L syringe only

C. Verify calibration with a biological control subject

D. Check the pneumotachometer against a rotameter



Correct Answer: A



Explanation: ATS/ERS standards require daily volume calibration of spirometers using a 3-L
syringe across a range of flows to verify accuracy and linearity. Clinical pearl: Low-flow and
high-flow calibration checks detect flow sensor nonlinearity.



Question 2



A technologist notices that the mouth pressure gauge on a body plethysmograph reads 2 cm
H₂O when the shutter is closed and the patient is not breathing. What is the most likely
cause?

,A. The pressure transducer requires recalibration

B. The patient is generating positive pressure

C. The box door seal is leaking

D. The breathing valve is stuck in the open position



Correct Answer: A



Explanation: A nonzero baseline pressure with a closed shutter and no patient effort
indicates transducer drift requiring recalibration. Best practice: Verify pressure zeroing
before each patient.



Question 3



Which of the following gases requires a dedicated analyzer with a katharometer for
measurement during lung volume testing?



A. Carbon dioxide

B. Helium

C. Nitrogen

D. Carbon monoxide



Correct Answer: B



Explanation: Helium concentration is measured by thermal conductivity (katharometer)
during helium dilution lung volume testing. Clinical pearl: Helium analyzers require regular
calibration with known gas concentrations.



Question 4

,A technologist is setting up equipment for a methacholine challenge test. Which safety item
must be immediately available at the bedside?



A. A 12-lead ECG machine

B. A spirometer with a bacterial filter

C. A short-acting beta-agonist inhaler

D. Supplemental oxygen via nasal cannula



Correct Answer: C



Explanation: A short-acting bronchodilator must be immediately available to reverse severe
bronchoconstriction during bronchoprovocation. Best practice: Confirm emergency
medications and protocols before initiating any challenge.



Question 5



During calibration of a blood gas analyzer, the technologist notes that the pH value for the
low calibrant is outside the acceptable range. What is the most appropriate initial action?



A. Report patient results using the current calibration

B. Repeat calibration with fresh calibrant solutions

C. Adjust the analyzer's internal pH slope manually

D. Perform a two-point calibration using only the high calibrant



Correct Answer: B



Explanation: Out-of-range calibration values often result from expired or contaminated
calibrants; fresh solutions should be tried first. Clinical pearl: Document all calibration
failures and corrective actions.

, Question 6



A technologist is preparing a DLCO system for testing. Which gas mixture is standard for the
single-breath technique?



A. 0.3% CO, 10% He, 21% O₂, balance N₂

B. 0.3% CO, 10% CH₄, 21% O₂, balance N₂

C. 1.0% CO, 5% He, 21% O₂, balance N₂

D. 0.1% CO, 15% Ne, 21% O₂, balance N₂



Correct Answer: A



Explanation: The standard DLCO test gas contains 0.3% CO and 10% helium as the tracer gas
with 21% oxygen. Clinical pearl: Helium allows calculation of alveolar volume from single-
breath dilution.



Question 7



What is the primary purpose of a biological control subject in a pulmonary function
laboratory?



A. To calibrate the spirometer daily

B. To verify that equipment and technique produce stable longitudinal results

C. To establish new predicted reference values

D. To train new technologists in testing procedures



Correct Answer: B

Document information

Uploaded on
October 19, 2026
Number of pages
103
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$27.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
305
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions