This study guide covers the ICC 93 exam on tall mass timber buildings, with practice questions and correct answers plus rationales. Topics include CLT fire resistance, char rates, shear walls, diaphragms, connections, moisture control, and performance-based design. Use it to review key code provisions and prepare for the exam with realistic questions and clear explanations.

Content preview

ICC 93 Tall Mass Timber Buildings Exam
with Practice Questions And Correct
Answers (Verif

1. Under ICC 93, a 12-story mass timber building uses exposed CLT floor panels. If
the required fire-resistance rating is 2 hours and the char rate for the CLT is 1.5
inches per hour, what minimum initial thickness must be provided to ensure a residual
cross-section after 2 hours of fire exposure? Assume no char contribution from the
adhesive and a 20% reduction for rounding.

A. 3.0 inches
B. 3.6 inches
C. 4.2 inches
D. 5.0 inches

Answer: B. 3.6 inches
Rationale: Char depth = 1.5 in/hr × 2 hr = 3.0 in. With 20% reduction for rounding,
required initial thickness = 3..8 = 3.75 in, rounded to 3.6 in per code. Options A, C,
and D misapply the reduction or ignore it entirely.


2. In a tall mass timber building with a CLT shear wall system, which seismic
force-resisting system is permitted under ICC 93 for structures over 6 stories?

A. Ordinary plain concrete shear walls
B. Special reinforced concrete shear walls
C. CLT shear walls with special detailing
D. Steel buckling-restrained braced frames

Answer: C. CLT shear walls with special detailing
Rationale: ICC 93 explicitly permits CLT shear walls with special detailing for tall mass
timber buildings, provided they meet ductility and overstrength requirements. Options A, B,
and D are either non-timber systems or not addressed in ICC 93 for this application.




Page 1 of 86

,3. A 10-story mass timber building uses glulam columns. To achieve a 1-hour
fire-resistance rating, which of the following is the most effective method according to
ICC 93?

A. Applying intumescent paint
B. Encapsulating with gypsum board
C. Using a sacrificial wood layer
D. Increasing column cross-section

Answer: B. Encapsulating with gypsum board
Rationale: ICC 93 recognizes encapsulation with gypsum board as a prescriptive method
for achieving fire-resistance ratings in mass timber. Intumescent paint is not a recognized
method, sacrificial wood is less common, and increasing cross-section alone does not
guarantee a rating.


4. For a CLT floor panel in a tall mass timber building, what is the primary purpose of
a concrete topping according to ICC 93?

A. To increase fire resistance
B. To improve acoustic performance
C. To provide composite action
D. To reduce deflection

Answer: B. To improve acoustic performance
Rationale: ICC 93 emphasizes acoustic separation in mass timber buildings, and a
concrete topping is often used to improve acoustic performance. While it can add mass and
reduce deflection, the primary code-driven purpose is acoustics.




Page 2 of 86

,5. In a performance-based design for a tall mass timber building, which parameter is
most critical for demonstrating equivalent fire safety to a prescriptive design?

A. Char rate of the timber
B. Time to flashover
C. Smoke development rate
D. Structural redundancy

Answer: A. Char rate of the timber
Rationale: The char rate directly determines the remaining structural capacity during a fire
and is fundamental to performance-based fire design. Other factors are important but
secondary to the char rate in structural fire engineering.


6. Which of the following connection details is most susceptible to moisture-induced
degradation in a tall mass timber building?

A. Steel plates with stainless steel bolts
B. Concealed steel angles in exterior walls
C. Galvanized steel brackets in interior dry areas
D. Aluminum connectors in conditioned spaces

Answer: B. Concealed steel angles in exterior walls
Rationale: Concealed steel angles in exterior walls are exposed to moisture and
temperature variations, leading to corrosion and potential degradation. Stainless steel and
galvanized options are more corrosion-resistant, and interior dry areas pose less risk.




Page 3 of 86

, 7. When designing a tall mass timber building for wind loads, which factor most
significantly affects the dynamic response?

A. Building mass
B. Damping ratio
C. Foundation type
D. Cladding type

Answer: B. Damping ratio
Rationale: The damping ratio critically influences the dynamic amplification of
wind-induced vibrations. Mass and stiffness affect frequency, but damping directly controls
response magnitude. Foundation and cladding have secondary effects.


8. In ICC 93, what is the maximum allowable height for a mass timber building with
an automatic sprinkler system and 2-hour fire-resistance-rated construction?

A. 120 feet
B. 180 feet
C. 270 feet
D. No limit

Answer: C. 270 feet
Rationale: ICC 93 permits heights up to 270 feet for mass timber buildings with sprinklers
and 2-hour ratings. Options A and B are lower limits for other construction types, and D is
incorrect as there are limits.




Page 4 of 86

Document information

Uploaded on
October 16, 2026
Number of pages
86
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$29.00

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
PROFICIENTPRO
3.0
(1)
Sold
4
Followers
0
Items
3343
Last sold
15 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions