Prepare for the New Hampshire Gas Piping Installer (GPI) Exam with this NFPA 54 study guide and practice questions resource designed to support gas piping installer licensing preparation. Review important topics that may include natural gas and propane properties, fuel gas theory, reading piping plans and drawings, gas pipe sizing calculations, approved piping materials, above-ground and underground installations, pressure regulators, piping assembly methods, system purging, pressure testing, leak detection, gas safety, and applicable New Hampshire licensing rules. This resource is intended to help aspiring gas piping installers and fuel gas professionals reinforce code knowledge, practice exam-style questions, and identify areas requiring additional review. For accurate preparation, consult the applicable NFPA 54 edition, current New Hampshire Mechanical Licensing Board rules, and official examination guidance. Confirm the code edition required for your specific exam, as the edition adopted by the state may differ from the newest published edition.

Content preview

NH GPI Exam | NFPA 54 Study Guide & Practice Questions

What is the minimum percentage needed to pass a written 70%
test for each specialty license?



What is the first tier to the specialty license? Gas Piping Installer




How many hours of educational training are required for 60 Hours (Safemec 305.02)
the first specialty license?



How many hours of on-job-training are required for the first 1000 Hours (Safemec 305.02)
specialty license?



What is the second tier to the specialty license? Fuel Gas Installation Technician




How many hours of educational training are required for 100 Hours Total (Safemec 305.03)
the second specialty license?



How many hours of on-job-training are required for the 1000 On Job Training Hours (Safemec 305.03)
second specialty license?



What is the third tier to the specialty license? Fuel Gas Service Technician




How many hours of educational training are required for 140 Hours (Safemec 305.04)
the third specialty license?



How many hours of on-job-training are required for the 2000 On Job Training Hour (Safemec 305.04)
third specialty license?



How much does the initial fuel gas trainee license cost? $90.00




How much does the initial fuel gas trainee renewal cost? $80.00




How many years is a license active before expiration? 2 Years




When does a license expire? At the end of the month the license was orginally issued (2 years)




How many questions at minimum are required on each 100
specialty license test?




Grade A+ | Updated

, NH GPI Exam | NFPA 54 Study Guide & Practice Questions

What code covers the 1st and 2nd stage regulators on a NFPA58
LP system?



A gas piping system was installed per code requirements Contact the AHJ (it may fall under reciprocity)
in 2000, and now due to new or revised code material it no
longer meets code, we shall we do?


Which table shall be referenced to design a gas piping 6.3.1(D)
system to have no more than a, .5" W.C. pressure drop for
the following conditions; LP gas, 11" W.C. available supply
pressure and black iron pipe?


Which Table shall be referenced to design a gas piping 6.3.1(F)
system to have no more than a .5" W.C. pressure drop for
the following conditions; LP gas, 11" W.C. available supply
pressure and soft copper tubing?


Which Table shall be referenced to design a gas piping 6.2.1(B)
system to have no more than a .5" W.C. pressure drop for
the following conditions; natural gas, 6" W.C. available
supply pressure and black iron pipe?


What do first stage regulators compensate for? Change in supply




When adding appliances to an existing system what shall Pull a permit
we do?



What shall we do to black iron piping installed outdoors Paint it
above ground?



What do 2nd stage regulators compensate for? Changes in downstream demand




What can cast iron be used for? Nothing




What Can't cast iron be used for? Everything




What is Industry best practice pressure drop we design 0.5" w.c
piping systems for



Do regulators need to be readily accessible? Yes




Do meters need to be readily accessible? Yes




Grade A+ | Updated

Document information

Uploaded on
October 14, 2026
Number of pages
11
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
WinningGrades
4.9
(16)
Sold
43
Followers
0
Items
2339
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions