Repair Exam and Correct Answers.
Which of the following is not considered hanging hardware?
nozzle, swivel, whip hose, shear valve - Answer shear valve
Per EO. VR-201-E, the dispenser must be removed from service if the dispensing vacuum of the
Healy VP-1000 pump is below how many inches of water column? - Answer 60
In a coaxial hose for a balance system, the product flows through the? - Answer inner hose
Per the Vapor Recovery Equipment Defects List (VRED), the _________ of any component
required to be used by the system's EO is not considered a defect. - Answer disconnection
The three elements in a fire triangle are? - Answer fuel, oxygen & ignition source
According to PEI RP-300, a combustible gas indicator is used to ? - Answer detect vapor leaks
in the vapor recovery system
Per CP-201, liquid traps in the dispenser vapor piping are: - Answer not allowed
Which of the following is not an overfill device ?
ball-float, tank overfill alarm, spill-bucket, drop-tube flapper valve - Answer spill-bucket
Piping should have a minimum and maximum slope of ______ inch - Answer l/8"-1/4"
What is the appropriate way to clean up a small spill of gasoline? - Answer apply absorbent to
the affected area, then remove & dispose of absorbent in accordance with applicable
requirements
Placing a bare copper wire from the __________ to the _________with it's ends exposed is
helpful with pipe run locating. - Answer Dispenser pipe run to the Tank Turbine
One of the approved methods for overfill prevention is to have an overfill device that will
automatically shut off fill into the tank when the tank is a maximum of _____ percent full. -
Answer 95%
, In the PEI 300 manual, pressure decay, dynamic back pressure and A/L testing satisfy who's
testing requirements? - Answer CARB
When removing liquid from a sump or spill bucket and the liquid contains fuel, it must
_________ - Answer be managed as hazardous waste
Before working on any electrical circuits always de-energize and use _____ rules. - Answer
NFPA
The two point Phase I vapor recovery system requires that a separate vapor recovery riser pipe
be installed in the tank and be equipped with a _____ ? - Answer vapor recovery adaptor
The term hanging hardware refers to? - Answer nozzle-hose-breakaway
A valve installed in a motor-vehicle fueling hose designed to separate with little or no product
spillage when excessive pulling force is placed on the hose is called a ____________ - Answer
breakaway
In the PEI# 500 manual, a Level II Qualified Person can do all EXCEPT: open cabinet doors,
reconnect breakaways, measure flow rates, repair or replace dispenser components - Answer
repair or replace dispenser components
A Gilbarco Vapor- Vac, OPW Vapor Saver system is considered to have a vapor recovery
equipment defect (VERD) if the vapor escape guard on an OPW 12-VW nozzle is missing or
damaged on at least ___% of the circumference of the device? - Answer 75
Typically, vapor return piping is connected to: - Answer the lowest grade gasoline tank
CARB's most recent vapor recovery regulations are known as: - Answer EVR (enhanced vapor
recovery)
A liquid collection point is installed in: - Answer the vapor return piping
The connection of vent risers aboveground to form a single vent opening is called a
_______________ - Answer manifold