EPA 608 Type 3 Study Guide Questions | 2026/2027 | Answers | With Complete Solutions

Document preview thumbnail
Preview 3 out of 19 pages

EPA 608 Type 3 Study Guide Questions | 2026/2027 | Answers | With Complete Solutions

Content preview

EPA 608 Type 3 Study Guide Questions | 2026/2027 |
Answers | With Complete Solutions

____________________ indicates air in a low-pressure system
Correct Answers High Head Pressure

____________________ must not be installed in series Correct
Answers Pressure Relief Valves

_____________________ require purge units because they
operate below _____________________. The primary purpose
of a purge unit is to remove ____________________ that leak
into a low-pressure chiller system. The purge unit gets its
suction from a connection on top of the ______________ where
most non-condensables accumulate. After separating the air
from the refrigerant, the purge unit sends the refrigerant back to
the ________________. High head pressure indicates _______
in a low-pressure system and that the purge unit may not be
______________ properly. Excessive running of a purge system
on a low-pressure chiller generally indicates a ____________
system. High-efficiency purge units will discharge a low
percentage of _____________ with the air they remove. Correct
Answers Low-pressure chillers, atmospheric pressure, non-
condensables, condenser, evaporator, air, operating, leaking,
refrigerant

A 15 psig rated rupture disc is located on the _____________ of
a centrifugal chiller. When charging, refrigerant is introduced
through the evaporator ________________, make sure not to
__________-pressurize the system. Correct Answers
evaporator, charging valve, over

,A certified service technician not being available CANNOT be
used as a reason to
_____________________________________ Correct Answers
Extending Appliance Repair Deadlines

A follow-up leak verification test must be conducted
______________ after a chiller with a charge of 200 pounds of
refrigerant has passed the initial verification leak test Correct
Answers Within 10 Days

A hydrostatic tube test kit is used to determine if a tube is
__________. When leak testing a low-pressure centrifugal
chiller with nitrogen, the maximum test pressure is ______ psig.
Leak testing a low-pressure refrigeration system with nitrogen in
excess of 10 psig could cause the _____________ to fail.
Charged low-pressure refrigeration machines may be most
efficiently leak checked by adding heat with circulated
_____________ or _______________. To reduce refrigerant
loss from the purge unit on an R-123 chiller, always leak test
and repair the __________. A low-pressure refrigeration system
could have a leak in the condenser or chiller barrel tubes if
excessive moisture continuously collects in the __________
unit. Correct Answers leaking, 10, rupture disc, hot water,
heating blankets, chiller, purge

A low-pressure chiller used for comfort cooling must be
repaired if it has an annual leak rate of ______ of the total
charge.

A. 10 percent

, B. 20 percent
C. 30 percent
D. 50 percent Correct Answers A

A safety precaution that should be adhered to for low-pressure
systems is the _________________________ when working
with liquid refrigerant Correct Answers Use of Gloves and
Safety Goggles

A water-cooled recovery unit will allow for ___________
recovery of large quantities of refrigerant. Water is circulated
through a chiller during refrigerant evacuation/ recovery to
prevent ____________ of water in the appliance. Correct
Answers faster, freezing

After all the liquid has been removed from an average 350 ton,
low-pressure appliance, approximately how much vapor
refrigerant remains in the system?

A. 100 pounds
B. 150 pounds
C. 350 pounds
D. 45 pounds Correct Answers A

After reaching the required recovery vacuum on a
_______________________, wait a few minutes to see if the
system pressure rises before ___________. When leaks in the
appliance make _________________ to the prescribed level
unattainable, do not proceed with the recovery. Recovery and
recycling equipment must be labeled as certified to meet

Document information

Uploaded on
October 7, 2026
Number of pages
19
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Classroom
4.0
(1208)
Sold
4995
Followers
3245
Items
56551
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions