Question 1.
Transtelephonic Monitoring

Correct Answer: Transmitted over phone to a LICENSED practitioner to read
(magnetic tape), Patients use up to 30 days


Question 2.
Digital Monitoring

Correct Answer: Transmitted over a computer where report is verified by a
licensed practitioner


Question 3.
Telemedicine monitoring is usually used to evaluate_____________

Correct Answer: Artificial Pacemaker Functioning


Question 4.
Ambulatory Monitor

Correct Answer: Most common type is holter monitor (continuous or
intermittent-only records when patient has symptoms. Used for dysrhythmias,
evaluation cardic meds, and checking pacemakers-24-48 hrs-up to 30 days


Question 5.
Procedure for applying ambulatory monitor (holter)

Correct Answer: Educate patient, equipment gathered and prepared,
electrodes placed on chest, equipment hooked up


Question 6.
Procedure for removing

Correct Answer: before removing, diary must be complete by patient, then
turn off recording, remove electrodes, clean skin, report results
*process is based on type of equipment uses


Question 7.
Functions of common ECG machine

Correct Answer: 3 basic functions are input, signal processing, output display.
Sensors in ECG machine serve as receiving devices for the electrical activity of

, the heart. INPUT-Electrode placed on patients skin direct impulses to ECG
instrument, providing the input. Signal processing happens in ECG machine,
output display is the result of processing and is shown on screen (known as
oscilloscope) and/or on ECG tracings. Electronic output is quickly becoming
most common choice for ECG tracings.


Question 8.
ECG machine controls

Correct Answer: # most common are speed, gain, artifact filter.
also have these controls: LCD display, heart rate limits, standardization, and
lead section


Question 9.
Speed control

Correct Answer: regulates how fast or slow the paper or data run during
procedure. MOST COMMONLY USED: 25 mm/sec
*increasing the speed for example to 50mm/sec will make wave forms appear
wider and is useful if patient heart rate is very fast. if you change the speed
you must note on tracing by circling the setting on tracing and notify the
healthcare provider
*speed in measure on a horizontial axis


Question 10.
Gain

Correct Answer: control on ECG machine that increases or decreases size of
ECG tracing. Normal setting is 10mm/mV. 20mm/V will double size and 5mm/V
will reduce size by half
* NEED TO KNOW mV is a millivolt-unit of measurement to indicate voltage-
Voltage is measures on a vertical axis


Question 11.
Artifact Filter

Correct Answer: unwanted marks on ECG tracing caused by something other
than heart activity
*Normal settings is between 40-150Hz, 40 Hz can be used to reduce artifact
• 3 most common causes of artifact are: -✓✓Somatic tremor, wandering
baseline, and AC interference


Question 12.
History of ECG

Correct Answer: 1903-Wilhelm Einthoven

Document information

Uploaded on
October 7, 2026
Number of pages
14
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$17.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
31
Followers
1
Items
15136
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions