New Hampshire Septic System Installer Exam Practice - Original Questions & Answers - Comprehensive Final Assessment - Detailed Rationales - Complete Exam - Most Popular Final TABLE OF CONTENTS FINAL COMPREHENSIVE: I. NH DES Env-Wq 1000 Overview Installer License II. Soil Evaluation Test Pit 5 Feet Minimum SHWT Redoximorphic Mottling Gray Observed Water March-June III. Separation 24 Inches to SHWT 48 Inches to Ledge Perc Test Depth Proposed Presoak IV. Perc Test Minutes Per Inch Sizing EDA Based on Rate V. Design Flow Bedrooms Flow 4BR 600 GPD Tank Sizing 4BR 1000 Gal 5BR 1250 Gal 6BR 1500 Gal Garbage Disposal Increase VI. Setbacks Env-Wq 1008 Tank 75 Feet Private Well Field 75 Feet Private Well 100 Feet Public Well Surface Water 75 Feet Wetlands 75 Feet Property Line 10 Feet Building 10 Feet VII. EDA Trenches Beds Chambers Trench Size 12 Inches Minimum Wide 18-36 Wide Depth 12-36 Aggregate 6 Below 2 Above Pipe D-box Level 5 Ports VIII. Mound Systems Required When Separation Cannot Be Met 24 Inches in Fill 48 Inches to Ledge ASTM C33 Sand Observation Ports IX. Pressure Distribution Required Mound Large Systems Perc 30 mpi Pump Chamber Manifold Even Distribution X. Installation Standards Pipe Slope 1/4 Inch Per Foot Watertight Tanks Floodplain No Increase Flood Level XI. Soil Types Suitable Loamy Sand Unsuitable Clay Perc 60 mpi Requires Alternative XII. Pumping Maintenance Every 3-5 Years Sludge+Scum 1/3 Tank Depth XIII. Replacement Systems Must Meet Current Standards New Permit Test Pits Perc No Grandfather XIV. Holding Tanks Last Resort No Feasible EDA DES Waiver Frequent Pumping Alarm No New Construction Hardship XV. Practice Questions 550 Comprehensive Final Each Asked Like Real NH Exam - Hinted Complete Exam XVI. Answer Key Detailed Rationales WELL-ASKED QUESTIONS FINAL (550Q COMPREHENSIVE): 1. What soil type is unsuitable for standard leach field in NH? A. Sand B. Clay with perc 60 min/inch rate 60 mpi unsuitable also high water table ledge within 24/48 inches requires alternative system C. Loamy sand D. Sandy loam Answer: B Rationale: Clay perc 60 min/inch unsuitable for standard field requires alternative system. 2. What is required for a replacement system in NH? A. Same as new B. Must meet current Env-Wq 1000 standards new permit required test pits perc tests required even if existing system no grandfather for replacement C. No permit D. Grandfathered Answer: B Rationale: Replacement system must meet current standards new permit test pits perc required no grandfather. 3. What is a holding tank and when allowed in NH? A. Always allowed B. Allowed only as last resort no other feasible EDA requires DES waiver frequent pumping alarm no new construction generally existing lots hardship C. Always for new homes D. No restrictions Answer: B Rationale: Holding tank last resort no feasible EDA DES waiver frequent pumping alarm no new construction generally hardship. ... 547 more comprehensive final review covering all Env-Wq 1000 ... WHY COMPREHENSIVE FINAL IS #1 BEST SELLER: - Covers All - Soil Evaluation Test Pit SHWT Redoximorphic, Separation 24/48 Inches, Perc Test, Design Flow Tank Sizing, Setbacks 75 Feet Well Surface Water, EDA Trenches Beds D-box, Mound Systems ASTM C33 Sand, Pressure Distribution, Installation Pipe Slope 1/4 Inch, Soil Types, Pumping, Replacement, Holding Tanks - Perfect for NH Septic System Installer Final Exam Preparation - Table of Contents Included - Well-Asked Real Exam Format - Hinted Complete Exam - Mixed Answers A=130 B=138 C=141 D=141 - Real Simulation - Original Questions & Answers + Detailed Rationales - Complete Exam FEATURES FINAL: - 550 Questions Mixed A/B/C/D - Table of Contents Included - Each Question Asked Like Real NH Septic Installer Exam - Well-Asked Vignettes - Hinted - Original Questions & Answers + Detailed Rationales - Complete Exam - Based on NH DES Env-Wq 1000 Subsurface Systems Rules Institution: New Hampshire DES Subsurface Systems | Course: Septic System Installer Exam | Format: PDF Instant Download TAGS: New Hampshire Septic System Installer Exam, Env-Wq 1000, Test Pit, Perc Test, Setbacks, Mound System, Original Questions Detailed Rationales, Complete Exam

Content preview

New Hampshire Septic System Installer Exam Practice - Original Questions & Answers - Comprehensive Final Assessment -
Detailed Rationales - Complete Exam
New Hampshire DES Subsurface Systems | Env-Wq 1000 | Septic System Installer License | Different Title 5


TABLE OF CONTENTS

1. I. NH DES Rules Env-Wq 1000 Overview - Subsurface Systems Bureau, Installer License Requirements Exam Experience CE
2. II. Soil Evaluation - Test Pit Requirements Depth 5 Feet Minimum, Seasonal High Water Table SHWT Redoximorphic Mottling Gray Colors
Observed Water March-June Monitor Wells
3. III. Separation Distances - 24 Inches Minimum Bottom of EDA to SHWT, 48 Inches to Ledge Refusal, Perc Test Depth Proposed System
Presoak
4. IV. Percolation Test - Soil Absorption Rate Minutes Per Inch, Test at Proposed Depth, Presoak, Sizing EDA Based on Rate
5. V. Design Flow - Bedrooms Flow 4 Bedroom 600 GPD, Septic Tank Sizing 4BR 1000 Gal 5BR 1250 Gal 6BR 1500 Gal, Garbage Disposal
Increase 20 Percent or 50 Percent Larger Tank
6. VI. Setbacks Env-Wq 1008 - Septic Tank 75 Feet Private Well Leach Field 75 Feet Private Well 100 Feet Public Well, Surface Water 75
Feet Wetlands 75 Feet, Property Line 10 Feet Building 10 Feet
7. VII. Effluent Disposal Area EDA - Trenches Beds Chambers, Trench Size 12 Inches Minimum Wide 18-36 Wide Depth 12-36 Aggregate 6
Below 2 Above Pipe, D-box Level 5 Ports Max Compacted Soil Accessible
8. VIII. Mound Systems - Required When Separation Cannot Be Met In-Ground, 24 Inches Separation Maintained in Fill, 48 Inches to Ledge,
ASTM C33 Sand Fill Observation Ports Licensed Installer
9. IX. Pressure Distribution - Required Mound Large Systems Perc greater than 30 mpi, Pump Chamber Pressure Manifold Small Holes Even
Distribution
10. X. Installation Standards - Pipe Slope 1/4 Inch Per Foot Tank to D-box 2 Percent Gravity Flow, Watertight Tanks, Floodplain Requirements
No Increase Flood Level
11. XI. Soil Types - Suitable Loamy Sand Sandy Loam, Unsuitable Clay Perc greater than 60 mpi High Water Table Ledge Within 24/48 Inches
Requires Alternative
12. XII. Pumping Maintenance - Every 3-5 Years Inspection Pump When Sludge plus Scum 1/3 Tank Depth
13. XIII. Replacement Systems - Must Meet Current Env-Wq 1000 Standards New Permit Test Pits Perc Required No Grandfather
14. XIV. Holding Tanks - Last Resort No Feasible EDA DES Waiver Frequent Pumping Alarm No New Construction Generally Hardship
15. XV. Practice Questions - Original Questions Each Asked Like Real NH Septic Installer Exam - Hinted Complete Exam
16. XVI. Answer Key with Detailed Rationales - Complete Exam

,NEW HAMPSHIRE SEPTIC SYSTEM INSTALLER EXAM - PRACTICE QUESTIONS - EACH QUESTION ASKED LIKE REAL

EXAM
Based on NH DES Env-Wq 1000 Subsurface Systems Rules, Setbacks, Test Pit, Perc Test, Design Flow, Mound Systems. High Yield.

1. What is required for a mound system in New Hampshire?
A. Only sand
B. No observation
C. No special requirements
D. Required when separation to water table or ledge cannot be met with in-ground - 24 inches separation maintained in mound fill, 48 inches to ledge,
observation ports, specific sand fill ASTM C33, licensed installer
Answer: D
Rationale: Mound required when separation cannot be met in-ground, maintain 24 inches to water table in fill, 48 inches to ledge, ASTM C33 sand,
observation ports, licensed installer.
2. What license is required to install septic in NH?
A. Only plumbing license
B. No license
C. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
D. No exam
Answer: C
Rationale: NH requires DES Septic System Installer license exam experience CE.
3. What is the purpose of a percolation test in NH septic design?
A. To find water table
B. To determine tank size
C. To find ledge
D. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
Answer: D
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
4. A 4-bedroom home in NH with 2.5 gpm well produces 600 gpd design flow. What size septic tank is required per NH rules?
A. 500 gallons
B. 1000 gallons minimum for up to 4 bedrooms per Env-Wq - 4 bedrooms 1000 gal tank, 5 bedrooms 1250 gal, 6 bedrooms 1500 gal - 600 gpd 4BR
needs 1000 gal
C. 1500 gallons
D. 750 gallons
Answer: B
Rationale: NH septic tank sizing: up to 4 bedrooms 1000 gal minimum, 5BR 1250 gal, 6BR 1500 gal per Env-Wq 1000.
5. How to determine seasonal high water table in NH test pit?
A. Only dig
B. No method
C. Only guess
D. Observe soil redoximorphic features mottling, gray colors, observed water level during wet season March-June, monitor wells
Answer: D
Rationale: SHWT determined by redoximorphic mottling gray colors observed water wet season March-June monitor wells.
6. How often must a septic tank be pumped in NH per DES recommendation?
A. Every year
B. Never
C. Every 3-5 years depending on use, tank size, garbage disposal - inspection every 3-5 years, pump when sludge+scum 1/3 tank depth
D. Every 10 years
Answer: C
Rationale: DES recommends pump every 3-5 years, inspect, pump when sludge+scum 1/3 depth.
7. What is a holding tank and when allowed in NH?
A. Allowed only as last resort no other feasible EDA, requires DES waiver, frequent pumping, alarm, no new construction generally - existing lots hardship
B. No restrictions
C. Always for new homes
D. Always allowed
Answer: A
Rationale: Holding tank last resort no feasible EDA DES waiver frequent pumping alarm no new construction generally hardship.
8. What license is required to install septic in NH?
A. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
B. No license
C. Only plumbing license

,D. No exam
Answer: A
Rationale: NH requires DES Septic System Installer license exam experience CE.
9. What is the role of a D-box (distribution box) in NH septic?
A. Only stores
B. No role
C. Only collects
D. Distributes effluent evenly to laterals - must be level, 5 ports max, set on compacted soil, accessible
Answer: D
Rationale: D-box distributes effluent evenly to laterals level 5 ports max compacted soil accessible.
10. What is required for septic system in floodplain in NH?
A. Can install anywhere
B. Must meet additional DES requirements - floodplain construction, no increase flood level, watertight tanks, check local floodplain ordinance Env-Wq
C. No requirements
D. Only tank
Answer: B
Rationale: Floodplain septic must meet DES floodplain requirements watertight tanks no increase flood level local ordinance.
11. What is the minimum size for a leach field trench in NH?
A. No minimum
B. 48 inches
C. Typically 12 inches wide minimum, 18-36 inches wide trenches, depth 12-36 inches, aggregate 6 inches below 2 inches above pipe
D. 6 inches wide
Answer: C
Rationale: Trench typically 12 inches minimum wide 18-36 wide depth 12-36 aggregate 6 below 2 above pipe per NH.
12. What is the purpose of a percolation test in NH septic design?
A. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
B. To find water table
C. To find ledge
D. To determine tank size
Answer: A
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
13. What is the minimum size for a leach field trench in NH?
A. No minimum
B. Typically 12 inches wide minimum, 18-36 inches wide trenches, depth 12-36 inches, aggregate 6 inches below 2 inches above pipe
C. 48 inches
D. 6 inches wide
Answer: B
Rationale: Trench typically 12 inches minimum wide 18-36 wide depth 12-36 aggregate 6 below 2 above pipe per NH.
14. A homeowner in New Hampshire wants to install a septic system on a lot with high seasonal high water table at 12 inches. What is the
minimum separation distance required between bottom of leach field and seasonal high water table per NH DES rules?
A. 6 inches
B. 24 inches minimum separation - bottom of bed must be 24 inches above seasonal high water table per Env-Wq 1000 - if 12 inches water table need fill
or mound
C. 0 inches
D. 12 inches
Answer: B
Rationale: NH Env-Wq 1000 requires 24 inches separation between bottom of leach field and seasonal high water table. If water table 12 inches need
mound system or fill.
15. What license is required to install septic in NH?
A. Only plumbing license
B. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
C. No license
D. No exam
Answer: B
Rationale: NH requires DES Septic System Installer license exam experience CE.
16. A septic installer in NH encounters a 12-inch diameter pipe from tank to D-box. What slope is required?
A. 1 inch per foot
B. No slope
C. Flat
D. 1/4 inch per foot minimum from tank to D-box - 2% slope - 1/4 inch per foot - ensure gravity flow
Answer: D

, Rationale: Pipe from tank to D-box requires 1/4 inch per foot minimum slope gravity flow.
17. What is a holding tank and when allowed in NH?
A. Always for new homes
B. No restrictions
C. Allowed only as last resort no other feasible EDA, requires DES waiver, frequent pumping, alarm, no new construction generally - existing lots hardship
D. Always allowed
Answer: C
Rationale: Holding tank last resort no feasible EDA DES waiver frequent pumping alarm no new construction generally hardship.
18. What license is required to install septic in NH?
A. No exam
B. Only plumbing license
C. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
D. No license
Answer: C
Rationale: NH requires DES Septic System Installer license exam experience CE.
19. What is required for a replacement system in NH?
A. Grandfathered
B. No permit
C. Must meet current Env-Wq 1000 standards - new permit required - test pits perc tests required even if existing system - no grandfather for replacement
D. Same as new
Answer: C
Rationale: Replacement system must meet current standards new permit test pits perc required no grandfather.
20. How to determine seasonal high water table in NH test pit?
A. No method
B. Only guess
C. Only dig
D. Observe soil redoximorphic features mottling, gray colors, observed water level during wet season March-June, monitor wells
Answer: D
Rationale: SHWT determined by redoximorphic mottling gray colors observed water wet season March-June monitor wells.
21. What is a holding tank and when allowed in NH?
A. No restrictions
B. Always for new homes
C. Always allowed
D. Allowed only as last resort no other feasible EDA, requires DES waiver, frequent pumping, alarm, no new construction generally - existing lots hardship
Answer: D
Rationale: Holding tank last resort no feasible EDA DES waiver frequent pumping alarm no new construction generally hardship.
22. What soil type is unsuitable for standard leach field in NH?
A. Loamy sand
B. Sandy loam
C. Clay with perc >60 min/inch - rate >60 mpi unsuitable - also high water table ledge within 24/48 inches - requires alternative system
D. Sand
Answer: C
Rationale: Clay perc >60 min/inch unsuitable for standard field requires alternative system.
23. What license is required to install septic in NH?
A. No exam
B. Only plumbing license
C. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
D. No license
Answer: C
Rationale: NH requires DES Septic System Installer license exam experience CE.
24. What is the purpose of a percolation test in NH septic design?
A. To find ledge
B. To determine tank size
C. To find water table
D. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
Answer: D
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
25. A 4-bedroom home in NH with 2.5 gpm well produces 600 gpd design flow. What size septic tank is required per NH rules?
A. 750 gallons
B. 500 gallons

Document information

Uploaded on
October 6, 2026
Number of pages
69
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$17.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GradeAchiver
2.3
(4)
Sold
39
Followers
2
Items
3370
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions