Georgia Electrical Contractor Class II (Unrestricted)
Examination | Latest Verified Questions and Detailed
Answers
OVERVIEW DESCRIPTION:
This Comprehensive set of multiple choice questions is designed for the Georgia
Electrical Contractor Class II (Unrestricted) examination, an open-book, multiple-choice
test administered by PSI that assesses candidates across comprehensive electrical
theory, National Electrical Code regulations, and business management. The
examination covers core content areas including NEC code rules, wiring methods,
equipment for general use, special occupancies, circuit analysis, grounding and bonding,
overcurrent protection, complex load calculations, transformers, motor controls, relays,
starters, project management, estimating, contract administration, and Georgia state
licensing regulations. Candidates are permitted to bring tabbed and highlighted
reference texts including the National Electrical Code, American Electricians' Handbook,
Contractors Guide to Business, Law, and Project Management, Code of Federal
Regulations (OSHA Part 1926), and Ugly's Electrical References.
QUESTION 1
Which device is specifically intended to provide a readily accessible means of
disconnecting electrical equipment from its supply?
A. Disconnecting means
B. Current transformer
C. Surge capacitor
D. Grounding electrode
CORRECT ANSWER: A
,2|Page
EXPERT RATIONALE:
A properly rated disconnecting means permits equipment to be separated from its
electrical supply. NEC Article 100 defines a disconnecting means as a device or group of
devices that disconnect conductors from their source of supply.
QUESTION 2
Why must electrical conductors be properly terminated at terminals, lugs, and other
connection points?
A. To eliminate the need for overcurrent protection.
B. To make every circuit operate at maximum voltage.
C. To ensure a low-resistance connection that prevents overheating.
D. To increase the conductor's ampacity rating.
CORRECT ANSWER: C
EXPERT RATIONALE:
Proper terminations ensure electrical continuity and prevent excessive heat buildup at
connection points. NEC 110.14 requires connections to be made with approved means.
QUESTION 3
What is the maximum voltage permitted on a Class II electrical contractor's work under
Georgia's licensing classification?
,3|Page
A. 120 volts
B. 240 volts
C. 480 volts
D. No voltage limitation within the scope of the license
CORRECT ANSWER: D
EXPERT RATIONALE:
Class II electrical contractors are non-restricted and may perform work without voltage
limitations applicable to restricted classifications. This permits work on high-voltage,
industrial, and complex commercial installations.
QUESTION 4
Which organization publishes the National Electrical Code (NEC)?
A. OSHA
B. NFPA
C. ICC
D. ANSI
CORRECT ANSWER: B
EXPERT RATIONALE:
The National Fire Protection Association (NFPA) publishes NFPA 70, the National
Electrical Code. The NEC is updated every three years through the NFPA standards
process.
, 4|Page
QUESTION 5
What is the primary purpose of the NEC?
A. To establish electrical utility rates
B. To provide minimum safety requirements for electrical installations
C. To establish contractor profit margins
D. To regulate electrical apprenticeships
CORRECT ANSWER: B
EXPERT RATIONALE:
The NEC establishes requirements intended to safeguard people and property from
hazards arising from electrical installations. It is a minimum safety standard, not a design
specification.
QUESTION 6
What is the unit used to measure electrical current?
A. Volt
B. Ohm
C. Ampere
D. Watt
CORRECT ANSWER: C