WhenCisCaCfacilityCrequiredCtoCpretreatCtheCwasteCtoCreduceCBOD5CandCTSSCtoC200mg/LCorCbelowCb
eforeCdisposalCthroughCaCconventionCorCchamberCsepticCtankCsystem?C-
CCORRECTCANSWERWhenCtheCfacilityCproducesCaCwasteCstreamCwithCBOD5CandCTSSChigherCthanC2
00Cmg/L
IsCphysicalCdevelopmentCofCaCpropertyCallowedCtoCstartCifCanCon-
siteCsewageCmanagementCsystemCwillCbeCused?CWhatCisCneededCforCconstructionCtoCstartCinstallin
gCanCon-siteCsewageCmanagementCsystem.C-
CCORRECTCANSWERNo.CACConstructionCPermitCfromCtheCCountyCHealthCDepartmentCisCneeded.
ListCtheCnineCitemsCneededCforCanCapplicationCfromCtheCCountyCHealthCDepartment.C-
CCORRECTCANSWER1.CNameCandCAddressCofCtheCownerCandCapplicantC(ifCotherCthanCowner)
2.LocationCofCproperty
3.CPlansCandCSpecificationsCshowingCtheClocationCandCdesignCofCproposedCsystem,CincludingCsurfac
eCandCsubsurfaceCdrainageCandCpiping
4.CNatureCofCtheCfacilityCtoCbeCserved
5.CLocationCofCallCwaterCsupplies,CgeothermalCborehole,CorCotherCutilitiesCandCtrashCpitsConCorCoffCt
heClot,CwhichCwillCbearCuponCtheClocationCofCtheCsystem
6.CNumberCofCbedroomsCinCtheCdwelling,CorCtheCnumberCofCpersonCtoCbeCservedCinCotherCtypesCofC
establishments,CorCotherCsewageCflowCorCwaterCusageCdata
, 7.CSoilCcharacteristics,CincludingCsoilCtypesCandCcapabilities,CfrequencyCandCevaluationsCofCseasona
lChighCgroundwaterCtables,CoccurrenceCofCrockCandCotherCimperviousCstrata
8.CSignatureCofCownerCorCagentCapplyingCforCpermit
9.CAnyCadditionalCinfoCdeemedCnecessaryCtoCdetermineCsuitabilityCofCtheCsite
WhenCcanCaCconventionalCorCchamberCsepticCtankCsystemCbeCusedConCtractsCorCparcelsCofClandCofCt
hreeCacresCorCmore?C-
CCORRECTCANSWERIfCtheCpercolationsCrateCdoesCnotCexceedC120CminutesCperCinch.
WhatCisCtheCmaximumCdesignCcapacityCofCaCconventionalCorCchamberCsepticCtankCsystem?C-
CCORRECTCANSWERNoClessCthanC1,000CgallonsCandCnoCmoreCthanC10,000Cgallons.
IfCtheCcountyCboardCofChealthCfindsCtheCsoilCevaluationCdeficient,ChowCanyCdaysCdoCtheyChaveCtoCno
tifyCtheCpersonCorCentityCthatCsubmittedCtheCevaluation?CHowCshouldCitCbeCsentCandCwhatCshouldC
beCincluded?C-
CCORRECTCANSWERTheCnotificationCneedsCtoCbeCsentCbyCmailCinCwritingCwithinC3CbusinessCdaysCan
dCincludeCanyCdeficiencies/CmeasuresCneededCtoCcorrectCdeficiencies.
SewersCconnectingCcomponentCpartsCofCon-
siteCsewageCmanagementCsystemsCshallCbeCofCsufficientCsizeCtoCserveC______C-
CCORRECTCANSWERanticipatedCflowCconditions
AllCsolidCpipesCandCfittingsCusedCinCanCon-
siteCsewageCmanagementCsystem,CbeginningCatCtheChouseCshallCbeC_______CandC________.C-
CCORRECTCANSWERNSFCInternationalCscheduleC40CPVCCorCequivalentCandCbeCaCminimumCofC4Cinc
hesCinCdiameter
WhatCisCtheCminimumCamountCofChoursCofCretentionCdoesCaCsepticCtankChaveCtoCprovide?C-
CCORRECTCANSWER24Chours
ACTUAL EXAM ALL QUESTIONS AND
WELL ELABORATED ANSWERS TOP
RATED VERSION FOR ALREADY A+
GRADED HIGHLY RECOMMENDED
|NEW AND REVISED
WhenCisCaCfacilityCrequiredCtoCpretreatCtheCwasteCtoCreduceCBOD5CandCTSSCtoC200mg/LCorCbelowCb
eforeCdisposalCthroughCaCconventionCorCchamberCsepticCtankCsystem?C-
CCORRECTCANSWERWhenCtheCfacilityCproducesCaCwasteCstreamCwithCBOD5CandCTSSChigherCthanC2
00Cmg/L
IsCphysicalCdevelopmentCofCaCpropertyCallowedCtoCstartCifCanCon-
siteCsewageCmanagementCsystemCwillCbeCused?CWhatCisCneededCforCconstructionCtoCstartCinstallin
gCanCon-siteCsewageCmanagementCsystem.C-
CCORRECTCANSWERNo.CACConstructionCPermitCfromCtheCCountyCHealthCDepartmentCisCneeded.
ListCtheCnineCitemsCneededCforCanCapplicationCfromCtheCCountyCHealthCDepartment.C-
CCORRECTCANSWER1.CNameCandCAddressCofCtheCownerCandCapplicantC(ifCotherCthanCowner)
2.LocationCofCproperty
3.CPlansCandCSpecificationsCshowingCtheClocationCandCdesignCofCproposedCsystem,CincludingCsurfac
eCandCsubsurfaceCdrainageCandCpiping
4.CNatureCofCtheCfacilityCtoCbeCserved
5.CLocationCofCallCwaterCsupplies,CgeothermalCborehole,CorCotherCutilitiesCandCtrashCpitsConCorCoffCt
heClot,CwhichCwillCbearCuponCtheClocationCofCtheCsystem
6.CNumberCofCbedroomsCinCtheCdwelling,CorCtheCnumberCofCpersonCtoCbeCservedCinCotherCtypesCofC
establishments,CorCotherCsewageCflowCorCwaterCusageCdata
, 7.CSoilCcharacteristics,CincludingCsoilCtypesCandCcapabilities,CfrequencyCandCevaluationsCofCseasona
lChighCgroundwaterCtables,CoccurrenceCofCrockCandCotherCimperviousCstrata
8.CSignatureCofCownerCorCagentCapplyingCforCpermit
9.CAnyCadditionalCinfoCdeemedCnecessaryCtoCdetermineCsuitabilityCofCtheCsite
WhenCcanCaCconventionalCorCchamberCsepticCtankCsystemCbeCusedConCtractsCorCparcelsCofClandCofCt
hreeCacresCorCmore?C-
CCORRECTCANSWERIfCtheCpercolationsCrateCdoesCnotCexceedC120CminutesCperCinch.
WhatCisCtheCmaximumCdesignCcapacityCofCaCconventionalCorCchamberCsepticCtankCsystem?C-
CCORRECTCANSWERNoClessCthanC1,000CgallonsCandCnoCmoreCthanC10,000Cgallons.
IfCtheCcountyCboardCofChealthCfindsCtheCsoilCevaluationCdeficient,ChowCanyCdaysCdoCtheyChaveCtoCno
tifyCtheCpersonCorCentityCthatCsubmittedCtheCevaluation?CHowCshouldCitCbeCsentCandCwhatCshouldC
beCincluded?C-
CCORRECTCANSWERTheCnotificationCneedsCtoCbeCsentCbyCmailCinCwritingCwithinC3CbusinessCdaysCan
dCincludeCanyCdeficiencies/CmeasuresCneededCtoCcorrectCdeficiencies.
SewersCconnectingCcomponentCpartsCofCon-
siteCsewageCmanagementCsystemsCshallCbeCofCsufficientCsizeCtoCserveC______C-
CCORRECTCANSWERanticipatedCflowCconditions
AllCsolidCpipesCandCfittingsCusedCinCanCon-
siteCsewageCmanagementCsystem,CbeginningCatCtheChouseCshallCbeC_______CandC________.C-
CCORRECTCANSWERNSFCInternationalCscheduleC40CPVCCorCequivalentCandCbeCaCminimumCofC4Cinc
hesCinCdiameter
WhatCisCtheCminimumCamountCofChoursCofCretentionCdoesCaCsepticCtankChaveCtoCprovide?C-
CCORRECTCANSWER24Chours